Configuration
© Rice Lake Weighing Systems ● All Rights Reserved 9
Auto Off (only applies to battery powered scales) – select amount of time of inactivity after which the scale automatically
powers off; settings:
•Off 1 – off after 1 minute of no use
• Off 3 – off after 3 minutes of no use
• Off 5 – off after 5 minutes of no use
• Off 30 – off after 30 seconds of no use
• Off – scale does not turn off
NOTE: configured earlier.
Backlight Shutdown – conserves battery life; select the amount of time of inactivity after which the backlight shuts off; settings: ON – always
on; AUTO – off after 5 seconds no activity; OFF – always off
Protocol – determines the manufacturer output protocol or serial setting the scale is configured for; check 3rd party software to confirm
correct selection; settings:
• NCI – general Serial Communications Protocol (782X and 76XX family), See Section 6.4.1 on page 16
•SMA – ECR Interface Protocol, See Section 6.4.2 on page 17
• Auto-1 – automatically transmit after stable weight above zero is removed from the scale platform
• Auto-2 – automatically transmit when the item is placed on the scale and the weight stabilizes
• Print – weight is transmitted only when the F1 button on the display panel is pressed
NOTE: If the scale is connected to a PC via the BenchPro USB port, the USB HID protocol is automatically selected;
USB HID settings are 1C19,0002
Not used in retail models; displays if is set to , or
Baud Rate – for RS-232 connection to PC; settings: 1200, 2400, 4800, 9600, 19200, 38400, 57600
Data Bits and Parity – for RS-232 connection to PC; settings: 7 even; 7 odd; 7 none; 8 none
Stop bits – for RS-232 connection to PC; settings: 1; 2
Enable or disable the tare button; settings: ON, OFF
Gravity Compensation – See Section 4.3 on page 10 for detailed information; settings:
•No – deactivated, calibrate scale with known accurate calibration weights
• Yes – view original calibration gravity and modify local gravity settings
Manufacturing mode only; do not use; do not adjust; settings: OFF, ON
Units of Measure – turn on and off units of measure; applicable settings are dependent on the model of scale purchased; most models have
a minimum of two units of measure turned on; to avoid incorrect weight being displayed or transmitted to the PC, only have the applicable
units of measure turned on; settings: lb, lb:oz, oz, kg, g
Capacity — defines the maximum capacity of the scale and determines the weight value to be used:
• When selecting lb, the calibration weight used must be in lb
• When selecting kg, the calibration weight used must be in kilograms
NOTE: Do not select capacities other than those indicated by the manufacturer
Not used in retail models
Calibration – See Section 5.0 on page 11 for detailed information
NOTE: To exit the calibration (
) parameter without saving changes, the unit must be powered off
Diagnostic menu – used to troubleshoot scale operation. See Section 7.1 on page 23 for more information; settings:
• RAM – displays if functioning properly; if anything else displays, contact RLWS for a new PCB
• ROM – displays if functioning properly; if anything else displays, contact RLWS for a new PCB
• div-A – Display internal counts after auto zero tracking
• div-O – Display internal counts
Done – exit the configuration menu, save settings and return to weigh mode
Bold indicates factory default setting
Parameter Description
Table 4-2. Service Menu Parameter Settings (Continued)