iDimension PWD Setup Manual
10 Visit our website www.RiceLake.com
Item No. Parameter Description
1 General Settings Auto Trigger Flats – Not applicable for this application, do not modify
Default: Off
Selections: On, Off
Auto Trigger Parcels – Not applicable for this application, do not modify
Default: Off
Selections: On, Off
Flat Detection – Not applicable for this application, do not modify
Default: Off
Selections: On, Off
Irregular Shape Object – Do not modify
Default: On
Selections: On, Off
Flat/Parcel Threshold (in) – Not applicable for this application, do not modify
Default: 1.2
Logging Level – Changing to error or debug will increase the amount of engineering and performance information
stored in the diagnostics and log files shown in “ipaddress/log” command
Default: debug
Self Recovery – Determines the recovery option of the unit:
Default: Off
Selections: Off, Restart, Reboot
Off
–
System will not perform a self recovery
Restart –
If the system has determined a critical error state, the unit will perform a restart of the software
and returns
the system to normal mode; If an object is under the device during a reboot, Wait will be
displayed on the USB display
Reboot – If the system has determined a critical error state, the unit will perform a reboot, an automatic
power cycle that clears the error and returns the system to normal mode; If an object is under the device
during a reboot; The USB display cycles power and return to normal operating mode
2 Scale Scale Type – The 880 indicator includes a custom NCI protocol setting to communicate with the PWD
Application setting required: NCI
Communication Parameters USB/RS-232 – The 880 indicator is configured for the following data:
Application setting required: 9600,N,8,1
Baud rate: 9600
Parity: None
Start bits: 8
Stop bit: 1
Use Scale Stable Status – Do not modify
Determines when the iDimension locks the displayed weight and dimensions on the touchscreen display;
Dimensions are locked and the remove state is displayed using both the scale stable reading and iDimension filter:
Default: Scale+QubeVu
Selections: Scale+QubeVu, QubeVu, Scale
Scale+QubeVu – This is the default factory setting and is recommended for use
QubeVu – Not recommended for use, using this feature may provide incorrect weight on the display;
Dimensions are locked and remove is displayed without checking if the scale is stable
Scale – Dimensions are locked and remove is displayed when the scale has returned a state
Wait Timeout –
Do not modify
The time in milliseconds the dimensions will wait for the scale to return a stable weight; System will timeout and
not return to the remove state; Increase this settings if the scale is in an unstable environment
Default: 3000
3 Low Resolution Camera
Switch Resolution Delay (ms) – Do not modify unless instructed by Rice Lake Weighing Systems dimensioning support
Default: 200
Image Format – Defines the image format used in QV/status
Default: BITMAP (.BMP)
Selections: BITMAP (.BMP), .JPEG
Table 3-3. General Settings Parameters