1 General Information
1.1 Keypad «CN-Keypad» (hereinafter, Keypad) works as a
component in security and other control and monitoring systems
along with corresponding devices which support wireless
«CN-Contact-R» exchange protocol. The keypad allows for entry
and exchange of information via two-way communication channel as
well as for indication of information in accordance with the indication
management codes received from the wireless network coordinator.
1.2 The keypad operates within the frequency range
433.05 … 434.79 MHz. Power emitted by transmitter does not exceed
10 mW. The keypad doesn’t require getting permits for purchase,
operation and registration.
1.3 To provide radio exchange between the keypad and extension
module two operating frequencies: main and reserve are used. The
keypad switches to reserve operating frequency automatically.
1.4 The keypad is powered by two lithium batteries CR123A type.
One is the main battery the other is the reserve battery.
1.5 The keypad has fourteen keys for entering information.
1.6 Two light indicators (red and green) and one sound emitter are
user to indicate the information and modes of operation.
1.7 The keypad generates and transfers the following messages:
«Battery Discharge» message if the power supply battery voltage
drops lower than 2.4-0.1 V and «Reserve battery discharge» message
if the reserve power supply battery voltage drops lower than 2.4-0.1 V.
1.8 The keys of the keypad have a backlight function.
1.9 The keypad is resistant to the effects of electromagnetic
interference.
2 Specifications
Table 1
Parameter Value
Operating temperature
minus 20 … +50 °С
Permissible relative humidity +25 °С up to 90 %
IP rating IP20
Dimensions, not more than 155 x 100 x 35 mm
Weight (without batteries, not more than 0.15 kg
Operating period under normal climate conditions
at average usage rating 4 times a day, not less than 24 months
Average service life, not less than
8 years
3 Scope of delivery
The keypad scope of delivery is referenced in Table 2.
Table 2
Name Qty
Keypad «CN-Keypad»
Lithium battery CR123А
Keypad «CN-Keypad». Installation Guide
1 pc.
2 pcs.
1 copy
4 Design
The keypad consists of the housing (1) with the installed printed
circuit board (PCB) (7) and battery compartment cover. Keys for
information entry, red (5) and green (2) light indicators, main battery
holder (3) and reserve battery holder (4) are located on the front side
of the keypad. The keypad mounting openings (6) for fixing the keypad
to a wall are located on the back cover of the keypad. «Reset» contacts
(8) are located in the housing window on PCB.
The keys for the information entry include:
- ten numeric keys from 0 to 9;
- «i» key;
- «#» key;
- « » key;
- « » key.
5 LED indications
LED indication modes are listed in Table 3.
Table 3
State LED Indication Notes
Operation in
«Binding» mode Periodic activation of the green
indicator light
Detector
registration in CP
«Binding» mode
finishing
Service LED indicator lighting red
for – 3 seconds
Confirmation of
any kay pressing,
Power supply is OK
Single green light indicator
short flashing and sound
indicator*
Confirmation of
any key pressing,
Power battery
require changing
Single green light indicator
short flashing and sound
signal*
Key sequence
identification failure
Periodic short flashing of
the red indicator and sound
indicator* for 0.6 sec
No connection
to CP
Alternating flashing of of red
and green indicators, as well as
periodic activation of the sound
indicator* for 1.6 seconds
Keypad settings
changed
Flashing of red and green
indicators, as well as a sound
indicator * for 0.6 seconds
After the commands
«Enable or disable
sound indication» or
«Enable or disable
the built-in key
illumination»
Object or section
status «Security
activated»
Red indicator is ON After command
«report status of
object or section»
Object or section
status «security
deactivated»
Green indicator id ON
Security activation
successful Red indicator is ON After command
«activate security of
object or section»
Security activation
failed
Tree flashes of red indicator
and sound indicator *
Exit delay in
progress
Periodic flashing of the red
indicator and sound indicator*
Security
deactivation
successful
Green indicator id ON After command
«deactivate security
of object or
section»
Security
deactivation failed
Tree flashes of green indicator
and sound indicator*
Entrance delay in
progress
Red indicator is ON, periodic
activation of sound indicator*
«Alarm button»
confirmation
Flashing of red and green
indicators for 1 second,
periodic activation of sound
indication* for 1 second After command
«Transmit Alarm
button»
«Alarm button»
is prohibited in
settings
Tree flashes of red and green
indicators and sound indicator*
Communication
quality apprising See section «Communication quality apprising»
«Norm» Turned off
*) – if sound indication is allowed
6 Binding with the CP
«Binding» mode is provided for the keypad logging in the CP and
for service information exchange.
KEYPAD
«CN-Keypad»
Installation Guide
Figure 1
1
6
7
5
3
2
46
8
9 Storage and Transportation
9.1 The keypad in original packing and without installed battery can
withstand the following conditions during transportation:
- transport jolting with the acceleration 30 m/sec2with impact
frequency from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
- ambient temperature minus 50 … +50 °С;
- relative air humidity (95 ± 3) % at the ambient temperature
+35 °С.
9.2 The keypad in it’s original manufacturer’s packing may be
shipped by any means of transportation in covered vehicles at any
distances in compliance with the rules of goods transportation valid
for corresponding type of transportation.
9.3 After transportation under the conditions different to operation
conditions the keypad shall be ready to operate after a maximum of
6 hours.
10 Manufacturer’s Guarantees
«RIELTA» JSC guarantees conformity of the Detector to it’s Technical
Specifications if conditions of transportation, storage, assembling and
operation are observed. The guaranteed storage period is 63 months
since the date of manufacturing the Detector.
The guaranteed period of operation is 60 months since the date of
commissioning within the storage period guaranteed.
For guaranteed maintenance, please contact:
«С.Nord»STCF
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC «Obvodny Dvor»
Phone: (812) 327-16-36
E-mail: [email protected], [email protected], www.cnord.ru
Note – Warranty obligations do not apply to the power supply
batteries.
11 Packing Certificate
Keypad «CN-Keypad» has been manufactured in compliance with
the active technical documentation, classified as fit for operation and
packed by «RIELTA» JSC.
Packing date _______________________________
month, year
Rev. 0 of 17.08.16
№
00251
6.1 Prepare the CP for the keypad logging in accordance to the
CP Installation Guide.
6.2 Open the battery cover of the keypad, install the reserve battery
into the holder (4) and main battery into the holder (3).
6.3 LED indicator periodically flashes green. This means that the
keypad is in the process of binding.
6.4 In case of no servic e LED indication, close the «Reset» contacts
for 2 – 3 seconds.
6.5. After successful logging red indicator turns on for 2 – 3 seconds.
6.6 The time allocated for the «Binding» mode is limited to 100 sec.
To renew the «Binding» mode, the «Reset» contacts should be closed
for 2 – 3 seconds.
7 Operation Aspects
All operational keys combinations and corresponding commands
are given in table 4.
Table 4
Command Keys combination
Report object status Press «i» key
Report section status Enter the section number and press «i»
Activate object security Press key « » and your code
Activate section security Press key « », enter section number, press
key «#» and enter your code
Deactivate object security Enter your code
Deactivate section security Enter the section number, press «#» key
and enter your code
Transmit «Alarm button» Simultaneously press and hold keys « » and
« » for 3 seconds
Enable or disable sound
indication
Simultaneously press and hold keys «#» and
«9» for 3 seconds
Enable or disable keypad
backlight
Simultaneously press and hold keys «#» and
«0» for 3 seconds
Report on CP
communication quality
Simultaneously press and hold keys «#»
and « »
8 Communication Quality Appraising
8.1 In order to determine the keypad and CP communication quality
it is recommended to do the following:
- insert main and reserve batteries in corresponding holders;
- install the keypad in the proposed mounting place;
- press «#» and « » keys simultaneously.
8.2 The keypad shall indicate the communication with CP quality
in accordance with Table 5.
Table 5
Indication Communication
quality appraising Recommendations
Tree short flashing of green
light indicator and sound
indicator activation*
Perfect
Install the keypad in
this place
Two short flashing of green
light indicator and sound
indicator activation*
Good
One short flashing of green
light indicator and sound
indicator activation*
Communication
can be established Choose other place
of installation or use
repeater**
Systematic flashing of green
and red indicators and
sound indicator activation*
for 1.6 seconds
No communication
*) – if sound indication is allowed
**) – «CN-Repeater»
By order of «С.Nord» STCF, www.cnord.ru
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC «Obvodny Dvor»,
Phone: (812) 327-16-36, [email protected]
Technical support: [email protected], http://support.cnord.ru
Made in Russia
The Manufacturer: «RIELTA» JSC, www.rielta.com
Russia, 197101, St. Petersburg, Chapaeva str., 17
Phone /fax: +7 (812) 233-03-02, 703-13-60, [email protected]
Technical support: phone +7 (812) 233-29-53, 703-13-57, [email protected]

Popular Keypad manuals by other brands

why pro WHY-KP user manual

why pro

why pro WHY-KP user manual

Ness M1 Navigator user manual

Ness

Ness M1 Navigator user manual

DMP Electronics 9863 installation guide

DMP Electronics

DMP Electronics 9863 installation guide

Satel INT-SF manual

Satel

Satel INT-SF manual

Dolphin DOLGDO315390 instructions

Dolphin

Dolphin DOLGDO315390 instructions

Spidertracks Spider X Keypad user manual

Spidertracks

Spidertracks Spider X Keypad user manual

RIB ACG9433D manual

RIB

RIB ACG9433D manual

Lonsdor KH100 user manual

Lonsdor

Lonsdor KH100 user manual

ENFORCER SK-2323-SDQ manual

ENFORCER

ENFORCER SK-2323-SDQ manual

Pasternack PE-9201 User manual & installation guide

Pasternack

Pasternack PE-9201 User manual & installation guide

Analog way Shot Box 2 quick start guide

Analog way

Analog way Shot Box 2 quick start guide

SECO-LARM ENFORCER SK-4131-SPSQ manual

SECO-LARM

SECO-LARM ENFORCER SK-4131-SPSQ manual

i4Home i4H-KP-3S manual

i4Home

i4Home i4H-KP-3S manual

Satel INT-TSG2 user manual

Satel

Satel INT-TSG2 user manual

Digiplex EVO641 user guide

Digiplex

Digiplex EVO641 user guide

SkyLink KN-318 user manual

SkyLink

SkyLink KN-318 user manual

Carefree 1050X owner's manual

Carefree

Carefree 1050X owner's manual

Risco Agility RW132KL1P user guide

Risco

Risco Agility RW132KL1P user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.