Ripley ODM RP 460 User manual

TECHNICAL SUPPORT DOCUMENT
RP 460
Quick Start Guide
Optical Power Meter
INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE ACCURATE AND RELIABLE, HOWEVER,
NO RESPONSIBILITY IS ASSUMED BY RIPLEY ODM FOR ITS USE NOR FOR ANY INFRINGEMENTS OF
PATENTS OR OTHER RIGHTS OF THIRD PARTIES THAT MAY RESULT FROM ITS USE. NO LICENSE IS
GRANTED BY IMPLICATION OR OTHERWISE UNDER ANY PATENT RIGHTS OF RIPLEY ODM.
THE INFORMATION CONTAINED IN THE PUBLICATION IS SUBJECT TO CHANGE WITHOUT NOTICE.
RIPLEY ODM LLC ■171 DANIEL WEBSTER HWY, UNIT 1 ■BELMONT, NH 03220 USA
P: (603) 524-8350 E: TECH.SUPPORT@ODM.RIPLEY-TOOLS.COM W: WWW.RIPLEY-TOOLS.COM
M-UM016-05

PAGE 2 M-UM016-05
Connector
Adapter
2 kHz Tone Indicator
Measurement Mode Indicator
LCD Screen
7
1
3
Save Button
4
Wavelength Button
9
Low Battery
Indicator
2
8
dB/dBm Button
10
Power Button
11
RCL Button
5
USB Button
6
1. Connector Adapter - Interchangeable
The RP 460 comes with a 2.5mm universal adapter. Additional adapters are available from
Ripley. Refer to page 5 for more information.
2. Low Battery Indicator
“BATT” will appear on the LCD screen when the CR2 3V battery needs to be recharged or
replaced, depending on the battery type.
3. 2 kHz Tone Indicator
A beep will sound and show “2 kHz” on the LCD once a 2 kHz modulated signal is recognized.
4. Save Button
Over 4000 readings may be saved on the RP 460. Each time the save button is pressed, the
current reading will be saved to internal storage. The display flashes the indexed location
where the reading has been saved.
5. RCL Button
Pressing the RCL button toggles through the saved readings on the device. The indexed
location, wavelength, and reading will flash on-screen.
6. USB Button
When the RP 460 is connected via USB to a computer running ODM® brand soware, pressing
this button will transfer all saved data points into the soware for reporting.
7. LCD Screen
The screen displays the measured value, selected wavelength, and status indicators.
8. Measurement Mode Indicator - dB/dBm
dB is a loss measurement. dBm is an absolute power measurement.
9. Wavelength Button
Hold the button to switch the RP 460 between the 850, 1300, 1310, 1490, 1550, 1611, and 1625
nm wavelengths. Press the button once to immediately display the current wavelength. The
selected wavelength will briefly appear on-screen every 8 seconds.
10. dB/dBm Button
Press the button to toggle between dB and dBm modes. Hold the button down when in dBm
mode to set a reference on the RP 460.

M-UM016-05 PAGE 3
11. Power Button
Press the button once to turn the RP 450 on. Press once again to turn the RP 460 o. The RP
460 will automatically turn o aer 5 minutes if inactive.
Important Safety Information
WARNING!
Read and understand all of the instructions and safety information in this manual
before operating this tool.
ELECTRIC SHOCK HAZARD
Contact with live circuits could result in severe injury or death. Pay attention to proper
battery polarity. Do not mix battery types or manufacturers. Do not open the unit. Use this
unit only for its intended purpose as outlined in this guide.
LASER HAZARD
Avoid eye exposure to open fiber connectors and interfaces when working with fiber
systems. They may be connected to a live laser source. Do not look into the output
port of a laser source. Point fiber endfaces toward non-reflective surfaces to prevent
reflection of laser.
ITEM DAMAGE HAZARD
Do not leave the item in direct sunlight or near heat sources, submerge in water, or
subject the unit to strong impact. Cover the fiber interface with the flip-cap when the
unit is not in use.
DO NOT THROW THIS PRODUCT AWAY
Contact your local recycling station to dispose of properly.
Function Tips
Audible Alerts
The RP 460 emits an audible beep each time a major function is used. To disable most
beeps, ensure that the unit is OFF. Press and hold the Save button, and turn the unit ON
while holding the Save button. Perform the same procedure to turn the audible beeps back
on.
Continuous Usage Mode
The RP 460 turns o automatically if no buttons are pressed for 5 minutes. To bypass this
feature, hold the Power button for 3 seconds when powering on. A series of beeps will
indicate that the unit is now in Continuous Mode and will not turn o automatically.
Reviewing Saved Readings
While in the RCL mode, use the Save and Wavelength buttons to navigate through the
saved readings on the device. Each reading has a “location” indicated by a 4-digit number.
Note the blue arrows on the Save and Wavelength buttons. The data cycles at either end.
Scrolling “up” from the last data point will cycle back to the first location (0001) and vice
versa.
Deleting Saved Readings
Press and hold the Save and Wavelength buttons simultaneously to delete all saved
readings in the RP 460's internal memory. The screen flashes 0000 to indicate that the
memory is empty.

PAGE 4 M-UM016-05
Non-Volatile Memory
The RP 460 uses a non-volatile memory system. Data is not lost if the unit is turned o while
testing, if the battery is removed, or if the unit is stored for long periods of time.
USB Download
Before transferring data from the RP 460 to the computer, download and install the ODM®
brand soware, available online at www.ripley-tools.com/downloads.
1. Plug the RP 460 into the computer using the included USB cable. If this is the first
time it has been plugged in, wait at least ten seconds for the drivers to install.
2. Place the ODM® brand soware into Dump/Sync mode by navigating to Settings >
Data Mode > Dump Mode.
3. Press the USB button on the RP 460 to dump/sync all data points. The data from the
RP 460 appears in the box on the le side of the window.
4. Fill out the fields on the right side of the window (Customer, User, Test Site, etc).
5. Navigate to Settings > Report Settings to identify a minimum and maximum value
for the PASS/FAIL functionality. Choose a color code scheme from this window, if
necessary.
6. To create the final report, click File > Export to Excel.
Data Streaming
The RP 460 can be used in a live streaming mode with the ODM® brand soware.
1. With the RP 460 plugged in via USB, place the ODM® brand soware into Active Mode
by navigating to Settings > Data Mode > Active Mode.
2. Click the Save button on-screen to save the live reading displayed in the window.
Save as many readings as needed.
3. To create the final report, click File > Export to Excel.
Maintenance
Unpacking & Inspection
The RP 460 is supplied with a so carry case, 2.5 mm adapter installed on the unit, 3.0V CR2
battery, USB cable, and an instruction card. Contact Ripley immediately if any part of the
unit or packaging is damaged, or otherwise unsatisfactory.
Low Battery
The RP 460 provides over 1000 operations under normal conditions. When the BATT
indicator is shown on the device screen, the CR2 battery should be recharged or replaced,
depending on the battery type.
Optical Connector Interface
The RP 460 is equipped with a universal connector adapter that is compatible with many
popular style connectors. The connector adapter interface should be kept covered and
protected from contamination. Care must be taken to avoid objects that may damage the
glass surface of the detector mount. If scratches or breaks occur on the surface, please
contact Ripley for proper service.
Calibration
All Ripley ODM® brand products include a 2-year warranty. Ripley recommends
recalibration every two years to ensure adherence to NIST measurement standards.
The first recalibration is free within the warranty period. Contact Ripley Tools for return
information.

M-UM016-05 PAGE 5
Specifications
Optical Power Meter
DETECTOR TYPE -02: InGaAs / -04: Filtered InGaAs
MEASUREMENT RANGE -02: +6 to -70 dBm / -04: +23 to -45 dBm
WAVELENGTH RANGE 850 nm to 1650 nm
SELECTABLE WAVELENGTHS 850 / 1300 / 1310 / 1490 / 1550 / 1611 / 1625 nm
RESOLUTION 0.01 dB
ABSOLUTE ACCURACY ± 0.25 dB (23° C +/- 2° C at 0 dBm)
OPTICAL INTERFACE Universal 2.5mm (Additional Adapters Available)
DISPLAY LCD
TONE ID 2 kHz
STORAGE 4000+ Measurements
DATA TRANSFER Mini-USB (Live Readings or Data Dump)
POWER Push Button Toggle / Auto OFF
OPERATING TEMPERATURE -10° C to +55° C
STORAGE TEMPERATURE -30° C to +70° C
BATTERY CR2
DIMENSIONS 6.1″ x 0.94″ x 0.75″ (15.5 x 2.38 x 1.9 cm)
WEIGHT 3 oz (85.4 g)
Power Meter Accessories
Optical Power Meter Adapters
PART NUMBER DESCRIPTION
AC 020 2.5 mm Universal Adapter
AC 021 1.25 mm Universal Adapter
AC 026 SC Adapter
AC 027 ST Adapter
AC 028 FC Adapter
AC 029 LC Adapter
Patch Cord & Battery Accessories
PART NUMBER DESCRIPTION
AC 500 SM SC-LC − 1m Simplex
AC 505 SM SC-ASC − 1m Simplex
AC 501 SM SC-SC − 1m Simplex
AC 502 SM LC-LC − 1m Simplex
AC 600 SC-SC − Simplex Bulkhead
AC 601 LC-LC − Simplex Bulkhead
AC 602 LC-LC − Duplex Bulkhead
AC 300 CR2 Non-Chargeable Battery (Pack of 5)
AC 310 CR2 Rechargeable Battery Charger w/ 2 Batteries
AC 311 CR2 Non-Chargeable Battery (Pack of 1)
AC 312 CR2 Rechargeable Battery (Pack of 1)

PAGE 6 M-UM016-05
Certifications
This product conforms with health, safety, and environmental protection standards for
products sold within the European Economic Area (EEA). This product was tested by an ISO
17025 accredited laboratory and complies with the following CE directives and standards
listed below:
Directives:
Electromagnetic Compatibility (2014/30/EU)
Standards:
EMC: EN 61326-1:2013 Industrial
Safety: EN/IEC61010-1:2010+A1:2016
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment o and on,
the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Contact Information
Contact us with any questions pertaining to this or any other ODM product.
Call Us:
() -
Email Us:
tech.suppor[email protected]
Visit Us Online: www.ripley-tools.com/odm
Warranty Information
Ripley ODM® brand test equipment is furnished with a 2 year warranty extending from
the original date of purchase. Contact Ripley Tools for information on recalibration and
repair of test equipment. Ripley makes every eort to ensure that all information in this
data sheet is accurate. Ripley Tools assumes no responsibility for any errors or omissions
and reserves the right to modify this document at any time without notice. Please contact
Ripley ODM® brand specialists for pricing and availability of equipment.
Other manuals for ODM RP 460
2
Table of contents
Other Ripley Measuring Instrument manuals

Ripley
Ripley Miller UPM100 User manual

Ripley
Ripley ODM DLS 355 User manual

Ripley
Ripley Miller DLS360 User manual

Ripley
Ripley ODM DLS 360 User manual

Ripley
Ripley Miller RP450 User manual

Ripley
Ripley MILLER DLS 655 User manual

Ripley
Ripley ODM VIS 500 User manual

Ripley
Ripley MILLER VIS300 User manual

Ripley
Ripley ODM RP 460 User manual

Ripley
Ripley ODM OTDR 800 User manual