Ripley ODM DLS 360 User manual

TECHNICAL SUPPORT DOCUMENT
DLS 360
Quick Start Guide
Dual Laser Source
INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE ACCURATE AND RELIABLE, HOWEVER,
NO RESPONSIBILITY IS ASSUMED BY RIPLEY ODM FOR ITS USE NOR FOR ANY INFRINGEMENTS OF
PATENTS OR OTHER RIGHTS OF THIRD PARTIES THAT MAY RESULT FROM ITS USE. NO LICENSE IS
GRANTED BY IMPLICATION OR OTHERWISE UNDER ANY PATENT RIGHTS OF RIPLEY ODM.
THE INFORMATION CONTAINED IN THE PUBLICATION IS SUBJECT TO CHANGE WITHOUT NOTICE.
RIPLEY ODM LLC ■171 DANIEL WEBSTER HWY, UNIT 1 ■BELMONT, NH 03220 USA
P: (603) 524-8350 E: TECH.SUPPORT@ODM.RIPLEY-TOOLS.COM W: WWW.RIPLEY-TOOLS.COM
M-UM009-03

PAGE 2 M-UM009-03
The DLS 360 dual laser source is a singlemode test laser used for verifying the proper
function of fiber optic networks. This document will serve as an overview of the major
features and functions of the device and oer tips for troubleshooting common issues in
optical networks.
Wavelength Indicator
Connector
Adapter Low Battery
Indicator
2 kHz Button
Power Button
2
4
13
5
Wavelength
Button
6
External
Power Port
7
1. Connector Adapter - Interchangeable
The DLS 360 comes with an SC screw-on adapter. Additional adapters are available from
Ripley. Refer to page 5 for more information.
2. Wavelength Indicator
This unit oers 1490 nm and 1625 nm wavelengths. When the DLS 360 is turned on, the red
light indicates which wavelength is selected. The red light blinks to indicate when the 2 kHz
modulation is turned ON.
3. Low Battery Indicator
A red indicator light appears when the CR2 battery power is low. Replace or recharge the
battery, depending on the battery type, to normal operation of the DLS 360.
4. Power Button
Use the power button to turn the DLS 360 ON and OFF. The unit will turn o automatically
aer 15 minutes. To bypass auto-shuto, hold the power button for 5 seconds when turning
ON.
5. 2 kHz Button
The 2 kHz button toggles the modulation of currently-selected wavelength output. The
laser flashes at 2000 times per second to provide a recognizable signal to a companion
power meter. Output power of the laser is reduced by 3 dB when the modulation is active.
6. Wavelength Button
The wavelength button switches between the 1490 nm and 1625 nm wavelength.
7. External Power Port
The port accepts the AC 030 power supply. The power supply is not a battery charger - just a
battery bypass.
Important Safety Information
WARNING!
Read and understand all of the instructions and safety information in this manual
before operating this tool.

M-UM009-03 PAGE 3
LASER HAZARD
Please note that 1490 nm and 1625 nm wavelengths are not visible to the human eye. Do
not look directly into the output port of the DLS 360 or directly into any fiber connector
that may be live.
Since the laser is invisible to the eye, the eye’s natural blink reflex is suppressed. This
can cause damage to the retina.
FDA 21 CFR 1040.10 & 1040.11
IEC 60825-1: 2007-03
Class 1 Laser Product
Transmitting Light
The DLS 360 transmits either the 1490nm or 1625nm wavelength on single-mode fiber. It is
important to use a test jumper to mate the DLS 360 to the fiber under test.
Test Jumper
Mate Connectors Appropriately
Signal Propagates Down Fiber
Output Power
The DLS 360 is calibrated to have an output power level of -5 dBm. Variations in power level
between -5 dBm and -8 dBm may be normal depending on the quality and age of the test
jumper, the DLS 360 output port, and other factors.
Always ensure that the DLS 360 is transmitting an acceptable power level before performing
an insertion loss test. Simply insert the test jumper (plugged into the DLS 360) into a
companion power meter set to the dBm mode. The power meter will indicate the measured
output power of the laser.
Test Jumper Plugged
Into Power Meter
Power Meter Displays
Output Power of Laser
Output Port Maintenance
The DLS 360 utilizes a physical fiber connection at the output port. It ensures a steady
power level for performing insertion loss tests.
Ensure that any test jumpers are inspected and cleaned before plugging into the DLS 360
unit. If soiled or damaged connectors are inserted, they can cause damage to the DLS 360
output port and the unit may need to be repaired.
The test jumper has physical contact with the
ferrule inside the DLS 360.

PAGE 4 M-UM009-03
TO CLEAN THE FERRULE INSIDE THE DLS 360:
• Unplug the test jumper
• Unscrew the adapter until it spins freely, then pull
• Inspect the ferrule with an approved microscope,
clean if necessary, and replace adapter
Using the 2 kHz Function
When the DLS 360's 2 kHz modulation is active, the selected wavelength indicator will
blink. The modulation is recognized by optical power meters further down the fiber and
indicated by a 2 kHz notification on the screen and a loud beep. The modulated tone can
also be recognized through the fiber jacket when a Live Fiber Identifier is used.
The LFI introduces a bend into the fiber which
leaks light from the core onto the detector of the
power meter. When using an LFI, expect a 30 to
35 dB oset in core power.
Testing Notes
Blue connectors (UPC) have a straight ferrule with a domed interface. Green connectors
(APC) have an eight-degree angled ferrule with a domed interface.
UPC and APC connectors are not compatible. NEVER connect UPC and APC connectors
together, OR plug an APC connector into the DLS 360 unit. This can cause irreparable
damage to both connectors.
Maintenance
Unpacking & Inspection
The DLS 360 is supplied with a so carry case, SC adapter installed on the unit, 3.0V CR2
battery, and an instruction card. Contact Ripley immediately if any part of the unit or
packaging is damaged, or otherwise unsatisfactory.
Low Battery
The DLS 360 provides over 1000 operations under normal conditions. When the LOW BAT
LED indicator is illuminated on the device, the CR2 battery should be replaced or recharged,
depending on the battery type.

M-UM009-03 PAGE 5
Optical Connector Interface
The DLS 360 is equipped with a SC/UPC connector adapter that is compatible with only SC/UPC
optical connectors. The connector adapter interface should be kept covered and protected
from contamination. Care must be taken to avoid objects that may damage the fiber inside the
adapter mount. Always inspect and clean fibers before mating them to the device. If scratches
or breaks occur on the fiber surface, please contact Ripley for proper service.
Calibration
All Ripley ODM® brand products include a 2-year warranty. Ripley recommends recalibration
every two years to ensure adherence to NIST measurement standards. The first recalibration
is free within the warranty period. Contact Ripley Tools for return information.
Light Source Accessories
Light Source Adapters
PART NUMBER DESCRIPTION
AC 022B SC Adapter
AC 023B FC Adapter
AC 024B ST Adapter
AC 025B LC Adapter
Patch Cord & Battery Accessories
PART NUMBER DESCRIPTION
AC 500 SM SC-LC − 1m Simplex
AC 505 SM SC-ASC − 1m Simplex
AC 501 SM SC-SC − 1m Simplex
AC 502 SM LC-LC − 1m Simplex
AC 600 SC-SC − Simplex Bulkhead
AC 601 LC-LC − Simplex Bulkhead
AC 602 LC-LC − Duplex Bulkhead
AC 300 CR2 Non-Chargeable Battery (Pack of 5)
AC 310 CR2 Rechargeable Battery Charger w/ 2 Batteries
AC 311 CR2 Non-Chargeable Battery (Pack of 1)
AC 312 CR2 Rechargeable Battery (Pack of 1)
AC 030 Battery Bypass
Ripley Tools oers the AC 030 wall plug for users who wish to
leave their DLS 360 turned on for long periods of time. This is
NOT a charger, but rather powers the unit from a wall outlet.
Specifications
Dual Single-Mode Laser Source
WAVELENGTH 1490 nm & 1625 nm
OUTPUT POWER -5.0 dBm
OUTPUT STABILITY ±0.05dB (1 Hour); ±0.03dB Long-Term (15 min warm-up)
SPECTRAL WIDTH 5 nm / 5nm
OPTICAL INTERFACE SC/FC/ST/LC Interchangeable
TONE OUTPUT 2 kHz
LASER CLASS Class 1 (FDA 21 CFR 1040.11)
POWER Push Button Toggle / Auto-OFF

PAGE 6 M-UM009-03
BATTERY CR2
OPERATING TEMPERATURE -10° C to +50° C
STORAGE TEMPERATURE -30° C to +60° C
DIMENSIONS 6.1″ x 0.94″ x 0.75″ (15.5 x 2.38 x 1.9 cm)
WEIGHT 3 oz (85.4 g)
Certifications
This product conforms with health, safety, and environmental protection standards for
products sold within the European Economic Area (EEA). This product was tested by an ISO
17025 accredited laboratory and complies with the following CE directives and standards
listed below:
Directives:
Electromagnetic Compatibility (2014/30/EU)
Standards:
EMC: EN 61326-1:2013 Industrial
Safety: EN/IEC61010-1:2010+A1:2016
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Contact Information
Contact us with any questions pertaining to this or any other ODM product.
Call Us:
() -
Email Us:
tech.suppor[email protected]
Visit Us Online: www.ripley-tools.com/odm
Warranty Information
Ripley ODM® brand test equipment is furnished with a 2 year warranty extending from
the original date of purchase. Contact Ripley Tools for information on recalibration and
repair of test equipment. Ripley makes every eort to ensure that all information in this
data sheet is accurate. Ripley Tools assumes no responsibility for any errors or omissions
and reserves the right to modify this document at any time without notice. Please contact
Ripley ODM® brand specialists for pricing and availability of equipment.
Table of contents
Other Ripley Measuring Instrument manuals

Ripley
Ripley Miller UPM100 User manual

Ripley
Ripley Miller RP450 User manual

Ripley
Ripley MILLER VIS300 User manual

Ripley
Ripley ODM OTDR 800 User manual

Ripley
Ripley Miller DLS360 User manual

Ripley
Ripley ODM RP 460 User manual

Ripley
Ripley ODM RP 460 User manual

Ripley
Ripley ODM DLS 355 User manual

Ripley
Ripley ODM VIS 500 User manual

Ripley
Ripley MILLER DLS 655 User manual
Popular Measuring Instrument manuals by other brands

Industrial Scientific
Industrial Scientific Radius BZ1 product manual

ISTEC
ISTEC 1700 Series installation instructions

Ibiza
Ibiza LAS-RG-OUTDOOR user manual

PCB Piezotronics
PCB Piezotronics J356A03/NC Installation and operating manual

AXIOMATIC
AXIOMATIC UMAXTC4CO user manual

Tektronix
Tektronix VM700T user manual