Rhein - Nadel Automation GmbH Page 3 Control Units for Vibratory Drives ESK2002
1.4 Accessoires
Label Denomination RNA-Mat-code
XS1,XS2,XS5 Connector, 5-poles 31002322 ( 50Hz Antriebe )
31002323 ( 100 Hz Antriebe)
XS3 Coupler connector, 5-poles, straight 35051144
XS3 Coupler connector, 5-poles, angular 35002546
XS4 Coupler connector, 12-poles, straight
XS4 Coupler connector, 12-poles, angular
2 Safety Instructions
It is always necessary to read and understand the
safety instructions. This ensures that valuable material
is not damaged and injuries are avoided.
Steps must be taken to ensure that all persons working
with this control unit are familiar with the safety
regulations and observe them.
The device described in this manual is a control unit
for operating RNA bowl feeders and linear feeders.
The limit values specified in the technical data must be
observed.
Note!
This hand indicates tips on
operation of the control unit.
Attention!
This warning triangle indicates
safety instructions. Failure to heed
this warning can lead to severe
injuries or death!
Work on electrical equipment of the
machine/plant may be carried out only by
a trained electrician or by untrained
persons under the leadership and
supervision of a trained electrician in
accordance with the regulations for
electrical engineering!
All safety and danger signs on the
machine/plant must be observed!
The electrical equipment of a
machine/plant must be inspected and
checked regularly. Defects such as loose
connections or damaged cables must be
remedied immediately!
Before commencing operation, make
sure that the earthing line (power earth,
PE) is intact and installed at the
connecting point. Only test instruments
approved for this purpose may be used
for checking the safety grounding
conductor.
3 Commissioning Instructions
Before connecting up to the mains and
switching on the control unit, it is essential
to check the following points:
• Is the control unit in proper working
condition and closed with all screws?
• Are the connector locks clicked
in/screwed secure?
• Are all cables and glands intact?
• Is PROPER INTENDED USAGE
ensured?
• Does the mains voltage specification on
the control unit agree with the local
mains voltage?
• Does the mains frequency specification
on the vibratory drive agree with the
local mains?
• Is the correct operating mode set on the
control unit? (See "Operating Mode"
section)
Operation of the control unit may be commenced only
when all questions asked above can be answered
unambiguously with YES.
Before you start operation after repair work
has been carried out or control
units/vibrating drives have been exchanged,
set the output on the control unit to minimum
before switching on. Check that the system
is working properly when you increase the
output.