15
6. Controller mode
The fixtures are individually addressed (001-497) on a data link and connected to the controller.The fixtures
respond to the DMX signal from the controller.
6.1 DMX addressing
Thecontrol panel on thefront panel of the fixture allows you to assign theDMX fixture address, whichis defined
as the first channel from which the SPOT 250 XT will respond to the controller.
If you set, for example, the address to channel 5, the SPOT 250 XT will use the channel 5 to 20 for control.
Please,be sure that youdon’thaveanyoverlappingchannels inorder to controleach SPOT 250 XTcorrectlyand
independently from any other fixture on the DMX data link.
If two, three or more SPOT 250 XT are addressed similarly, they will work similarly.
Foraddress setting, please referto the instructions under"Addressing"(menu "A001").
Controlling:
After having addressed all SPOT 250 XT , you may now start operating these via your lighting controller.
Note:After switching on, the SPOT 250 XT will automatically detect whether DMX 512 data is received or not.If
there is no data received at the DMX-input, the display will start to flash "A001" with actually set address.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the SPOT 250 XT
- the controller is switched off or defective, the cable or connector is defective or the signal wires are swap in the
inputconnector.
Note:It’s necessary to insert the XLR termination plug (with 120 Ohm) to the last fixture in the link in order to
ensure proper transmission on the DMX data link.
6.2 Remotely controllable functions
Lamp
The SPOT 250 XT is to be operated with a MSD/HSD 250 or MSD 250/2 GY-9,5 lamp.
Arelayinside of the SPOT 250 XTallowsyouto switchon andoff the lampvia the control panel or viayourDMX-
controller without affecting the rest of the lighting.
To switch On/Off the lamp, please refer to "Switching On/Off the lamp " (menu "LAMP").
Note: It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be
cold before re-striking. For this reason, you have to wait 5 minutes (max. speed of fan must be adjusted) after
having switched Off the lamp before you can switch it back On again. If you try to switch On the lamp within 5
minutesafter havingswitcheditOff,the SPOT250 XTwill store thisinformation andautomatically ignite thelamp
whenthe5 minutesperiodhas expired.Themessage "HEAt" will appearon thecontrolpanel displayof theSPOT
250 XT. If the ignition of the lamp is seven times unsuccessful, on the display will appear "LA.Er", meaning that
the lamp could be damaged or even missed, or there could be a failure on the ignitor or ballast.
Colour wheel
TheSPOT250XT featuresa colour-wheel with 12colour positions - 11of these with dichroiccolors and the last
one open.The wheel can be positioned between two adjacent colors in any position.It is also possible to rotate
the color-wheel continuously at different speeds - the so-called "Rainbow effect“ is created.
Rotating gobo wheel
The rotating gobo-wheel includes 4 metal gobos, 1 glass gobo and 1 multicolour dichroic gobo rotating in both
directions, indexable, rotating gobo wheel cont. rotation slow to fast.The multicolour dichroic gobo (containing
C,M,Ycolors) canbe combined withthe color-wheelespecially with cyan,magenta and yellowcolours inorder to
obtainseveraldifferentmulticolourbeams.
3-facet rotating prism
3-facet prism rotating in both directions at different speeds.