RoboVent PFX Series User manual

PFX Series
(PFX-) Cartridge Collectors
Owner’s Manual
Installation, Operation
& Maintenance
Revised 11-20-20


PFX Series
(PFX-) Cartridge Collectors
Owner’s Manual
Installation, Operation & Maintenance
Manufactured by:
RoboVent
37900 Mound Road
Sterling Heights, MI 48310 USA
(888) 762-6836
www.robovent.com
©2019 RoboVent Product Group, Inc. All rights reserved.
Models:
PFX-2000-1-M1632
PFX-2000-1-M1650
PFX-4000-2-M1650
PFX-4000-2-M1846
PFX-8000-4-M1870
PFX-8000-4-M1890
PFX-8000-4-C2255
PFX-12000-6-M1890
PFX-12000-6-M18120
PFX-12000-6-C2280
PFX Series

4 ROBOVENT • PFX SERIES OWNER’S MANUAL
Dear Customer,
Thank you for purchasing a PFX Series Fume Collector. This manual will help you install,
start-up, commission, maintain, and troubleshoot your new dust collector. Please take time
to read this manual thoroughly before installing and/or operating your unit.
When your PFX fume collector is due for scheduled maintenance, keep in mind that
RoboVent has specially trained staff to perform these tasks. If you would like one of our
qualified service staff to discuss a customized service plan for your factory, don't hesitate
to reach out. Our team can also discuss the wide array of replacement filter cartridges we
have in stock for purchase to maximize your dust collectors efficiency and performance. For
any technical issues you may experience, RoboVent has a dedicated technical support team
that is only a call away 24-7.
At RoboVent, we are committed to making your facility a safe and healthy environment
for your workers. We look forward to continuing to work with you!
The RoboVent Team
Congratulations!

ROBOVENT • PFX SERIES OWNER’S MANUAL 5
Important Safety Instructions ...................Section 100 .........................Page 7
Features of the PFX Series Collector .............Section 200 .........................Page 9
Receiving & Inspection ..........................Section 300 ........................Page 11
General Description .............................Section 400 .......................page 13
Specifications ...................................Section 500 ........................Page 15
Installation ......................................Section 600 ........................Page 27
Operation.......................................Section 700 ........................Page 29
Standard Maintenance .........................Section 800 ........................Page 31
Filter Change Maintenance......................Section 800 ........................Page 33
VFD Maintenance Procedure . . . . . . . . . . . . . . . . . . . .Section 900 ........................Page 35
Motor Greasing Guide......................... Section 1000 ........................Page 39
Troubleshooting .............................. Section 1100 ........................Page 49
Table of Contents


ROBOVENT • PFX SERIES OWNER’S MANUAL 7
SECTION 100
Important
Safety Instructions

8 ROBOVENT • PFX SERIES OWNER’S MANUAL
Failure to follow all instructions may result in electric
shock, bodily injury and/or destruction of the unit.
Use of controls, adjustments, or performance of
procedures other than those specified herein, may
result in electrical shock.
IMPORTANT SAFETY INSTRUCTIONS
1. Read all instructions thoroughly.
2. Heed all warnings.
3. Do not block intake or exhaust vents. Keep the exhaust
vent free from debris and materials that could restrict
airflow. Prolonged restriction could damage the motor and
electrical components. Any blockage of the air flow will
decrease efficiency of this unit.
4. Refer all service matters to qualified service personnel.
Servicing is required when the unit is damaged in any
way including the control panel, supply wiring or in the
case of excessive filter loading.
5. Disconnect power before working on the motor or
blower wheel. The motor or blower wheel should be
disassembled only by a factory authorized technician.
6. Risk of serious personal injury or death!
Use extreme care to make sure you are never in a
position where your body (or any item you are in contact
with, such as a screwdriver or test instrument) can
accidentally touch the blower wheel.
7. If welding stainless steel, special safety measures need to be
followed when maintaining collector. Consult your Safety
Director for further information on OSHA's Hexavalent
Chromium Standards.
SECTION 100
Important Safety Instructions

SECTION 200
Features of the
PFX Series Collector

10 ROBOVENT • PFX SERIES OWNER’S MANUAL
SECTION 200
Features of the PFX Series Collector
1. Filter Pressure Gauge
The control panel houses a Minihelic Differential
Pressure Gauge. This meter will aid the operator in
determining when cartridges should be changed
(see The Differential Pressure Gauge under
Operations).
2. Sturdy 10 GA Reinforced Construction
This Heavy-Duty construction secures a lifetime of
industrial use. Seams are robotically welded and
ground to assure there are no leaks or cracks that
could contaminate the facility air system.
3. Built-In SparkOut Plenum
RoboVent’s SparkOut Technology has been
incorporated into a specially designed crossflow
intake plenum. The intake creates a horizontal
airflow through the built-in SparkOut where sparks
are quickly extinguished. This exclusive engineered
design represents years of extensive field testing and
performance under heavy manual welding.
4. High Performance Blower Design
Each PFX Series Dust Collector comes with a single
Air Foil Blower with a direct drive motor. This highly
efficient blower design and direct drive system
maximizes the airflow (CFM) delivered by the motor
power requirements.
5. Front Door Filter Access
Filters are easily accessible through an
oversized front door. Filter replacement is made
easy and requires less time and effort than
traditional loading systems.
6. Acoustic Motor Plenum
High-density sound materials and Bass Trap
Acoustics have been implemented as part of
the blower compartment. The acoustically
designed plenum greatly reduces motor and
blower noise levels and decreases ambient
noise into the facility.

SECTION 300
Receiving &
Inspection

12 ROBOVENT • PFX SERIES OWNER’S MANUAL
Receiving
RoboVent equipment is typically shipped on skids or direct loaded. The number of
skids will vary, depending the type, size and accessories ordered. The skids or direct
loaded equipment are too heavy to lift by hand. The items will need to be unloaded by
an industrial forklift, crane, or overhead crane.
Inspection
A visual inspection of your equipment should be performed before it is removed from
the truck. Dents, scratches, and other damages should be noted on the shipping
documents, and also photographed. The structural integrity of the housing can
be adversely affected by large dents. RoboVent should be immediately notified
of any structural damage to your equipment. It is the purchaser’s responsibility to
file shortage reports and damage claims with the carrier and with your RoboVent
Representative. The carrier is responsible for any damage to the equipment while it is
in transit unless specific arrangements are made otherwise.
Compare the number of items received against the carrier’s bill of lading. Inspect all
items for apparent damage. Immediately report any shortages or obvious damage to the
carrier and to your local RoboVent Representative, call the factory at 1-(888)-762-6836,
or email: customer.service@robovent.com.
When all skids are completely unpacked and uncrated, check all items received against the
packing lists. Further inspect the unit and components for hidden damage. Again, report
any shortage or damage to the carrier and to your local RoboVent Representative.
The filter cartridges are typically shipped installed in your collector. Be sure to check them
for alignment, as they may have shifted during transit. If they have shifted, it is possible
that damage may have been done. Remove all filter cartridges and inspect thoroughly.
Note: Do not return any damaged components without first contacting your RoboVent
Representative to obtain a Returned Goods Authorization (RGA).
Small Parts
Carefully inspect all packing material before it is discarded, to be sure that no small parts
have been missed.
SECTION 300
Receiving & Inspection

SECTION 400
General Description

14 ROBOVENT • PFX SERIES OWNER’S MANUAL
SECTION 400
General Description
The PFX Series Collectors are a compact, self
contained dust collector unit specially designed
for ambient welding operations. Each PFX comes
outfitted with properly sized high-pressure blower, an
integral SparkOut Plenum to knock down the most
persistent sparks, and a complete electrical system.
General Operation
Smoke, dust and sparks first enter the PFX via the
SparkOut Plenum. Sparks, created through the
welding process, are quickly extinguished through
an engineered spark trap (SparkOut). Dust laden air is
then drawn through a series of box & bag filters and
returned into the facility as clean air.
Particulate and by-product contamination is
immediately stopped in its tracks by the High-
Efficiency Media.
RoboVent Acoustic Exhaust Plenum
RoboVent Acoustical Plenums are attached at the
outlet of the PFX.

SECTION 500
Specifications

16 ROBOVENT • PFX SERIES OWNER’S MANUAL
SECTION 500
Specifications
PFX Series Model #:
PFX-2000-1-M1632
Standard Filter Pack: Washable Metal Mesh—Part #: MM-24242
Roughing Filter—Part #: RF-24242-PP3
Absorption layer—Part #: PF-24244-35
Final Filter—Part #: BF-242429095
Blower Configuration: 3HP, 16”@32%
Dimensions: 101”W x 25”D x 28”H
Weight: 980 lbs.
Door Clearance: 50”
Filter Sets: 1
Airflow (CFM@5”W.C.): 1850
Silencing: Built-In Acoustical Lining
F.L. Amps: 3.7
Electrical Controls: Service Disconnect, Filter pressure gauge, Motor Starter,
460 Volt Standard
Standard Features:
• Heavy Duty Construction: Fully Welded 10 Gauge Steel
• Blower: Backward inclined, Type III, Direct Drive
• Filtration: Multi-Stage Filtration to Maximize Filter Life
• Nema 12 Super Seal Doors
Available Options:
• E-Drive: Automatically Adjust the Airflow via a VFD to Extend Filter Life
• AutoSaver: Auto On/Off Feature
• Supprex-200: A Proprietary Engineered Fire Suppression System
• Custom Filter Tracks: For Special applications
AInlet Area
BSilencer
CFilter Access Door
DControl Cabinet
AC
D
B
28"
101"
25"

ROBOVENT • PFX SERIES OWNER’S MANUAL 17
SECTION 500
Specifications
PFX Series Model #:
PFX-2000-1-M1650
Standard Filter Pack: Washable Metal Mesh—Part #: MM-24242
Roughing Filter—Part #: RF-24242-PP3
Absorption layer—Part #: PF-24244-35
Final Filter—Part #: BF-242429095
Blower Configuration: 5HP, 16”@50%
Dimensions: 101”W x 25”D x 28”H
Weight: 980 lbs.
Door Clearance: 50”
Filter Sets: 1
Airflow (CFM@5”W.C.): 2998
Silencing: Built-In Acoustical Lining
F.L. Amps: 3.7
Electrical Controls: Service Disconnect, Filter pressure gauge, Motor Starter,
460 Volt Standard
Standard Features:
• Heavy Duty Construction: Fully Welded 10 Gauge Steel
• Blower: Backward inclined, Type III, Direct Drive
• Filtration: Multi-Stage Filtration to Maximize Filter Life
• Nema 12 Super Seal Doors
Available Options:
• E-Drive: Automatically Adjust the Airflow via a VFD to Extend Filter Life
• AutoSaver: Auto On/Off Feature
• Supprex-200: A Proprietary Engineered Fire Suppression System
• Custom Filter Tracks: For Special applications
AInlet Area
BSilencer
CFilter Access Door
DControl Cabinet
AC
D
B
28"
101"
25"

18 ROBOVENT • PFX SERIES OWNER’S MANUAL
SECTION 500
Specifications
PFX Series Model #:
PFX-4000-2-M1650
Standard Filter Pack: Washable Metal Mesh—Part #: MM-24242
Roughing Filter—Part #: RF-24242-PP3
Absorption layer—Part #: PF-24244-35
Final Filter—Part #: BF-242429095
Blower Configuration: 5HP, 16”@50%
Dimensions: 103”W x 50.5”D x 31”H
Weight: 1450 lbs.
Door Clearance: 50”
Filter Sets: 2
Airflow (CFM@5”W.C.): 2998
Silencing: Built-In Acoustical Lining
F.L. Amps: 3.7
Electrical Controls: Service Disconnect, Filter pressure gauge, Motor Starter,
460 Volt Standard
Standard Features:
• Heavy Duty Construction: Fully Welded 10 Gauge Steel
• Blower: Backward inclined, Type III, Direct Drive
• Filtration: Multi-Stage Filtration to Maximize Filter Life
• Nema 12 Super Seal Doors
Available Options:
• E-Drive: Automatically Adjust the Airflow via a VFD to Extend Filter Life
• AutoSaver: Auto On/Off Feature
• Supprex-200: A Proprietary Engineered Fire Suppression System
• Custom Filter Tracks: For Special applications
AInlet Area
BSilencer
CFilter Access Door
DControl Cabinet
AC
D
B
31"
103"
50.5"

ROBOVENT • PFX SERIES OWNER’S MANUAL 19
SECTION 500
Specifications
PFX Series Model #:
PFX-4000-2-M1846
Standard Filter Pack: Washable Metal Mesh—Part #: MM-24242
Roughing Filter—Part #: RF-24242-PP3
Absorption layer—Part #: PF-24244-35
Final Filter—Part #: BF-242429095
Blower Configuration: 7.5HP, 18”@46%
Dimensions: 103”W x 50.5”D x 31”H
Weight: 1450 lbs.
Door Clearance: 50”
Filter Sets: 2
Airflow (CFM@5”W.C.): 4138
Silencing: Built-In Acoustical Lining
F.L. Amps: 9.2
Electrical Controls: Service Disconnect, Filter pressure gauge, Motor Starter,
460 Volt Standard
Standard Features:
• Heavy Duty Construction: Fully Welded 10 Gauge Steel
• Blower: Backward inclined, Type III, Direct Drive
• Filtration: Multi-Stage Filtration to Maximize Filter Life
• Nema 12 Super Seal Doors
Available Options:
• E-Drive: Automatically Adjust the Airflow via a VFD to Extend Filter Life
• AutoSaver: Auto On/Off Feature
• Supprex-200: A Proprietary Engineered Fire Suppression System
• Custom Filter Tracks: For Special applications
AInlet Area
BSilencer
CFilter Access Door
DControl Cabinet
AC
D
B
31"
103"
50.5"

20 ROBOVENT • PFX SERIES OWNER’S MANUAL
SECTION 500
Specifications
PFX Series Model #:
PFX-8000-4-M1870
Standard Filter Pack: Washable Metal Mesh—Part #: MM-24242
Roughing Filter—Part #: RF-24242-PP3
Absorption layer—Part #: PF-24244-35
Final Filter—Part #: BF-242429095
Blower Configuration: 10HP, 18”@70%
Dimensions: 101”W x 50”D x 53”H
Weight: 2270 lbs.
Door Clearance: 50”
Filter Sets: 4
Airflow (CFM@5”W.C.): 6296
Silencing: Built-In Acoustical Lining
F.L. Amps: 12
Electrical Controls: Service Disconnect, Filter pressure gauge, Motor Starter,
460 Volt Standard
Standard Features:
• Heavy Duty Construction: Fully Welded 10 Gauge Steel
• Blower: Backward inclined, Type III, Direct Drive
• Filtration: Multi-Stage Filtration to Maximize Filter Life
• Nema 12 Super Seal Doors
Available Options:
• E-Drive: Automatically Adjust the Airflow via a VFD to Extend Filter Life
• AutoSaver: Auto On/Off Feature
• Supprex-200: A Proprietary Engineered Fire Suppression System
• Custom Filter Tracks: For Special applications
AInlet Area
BSilencer
CFilter Access Door
DControl Cabinet
AC
D
B
53"
101"
50"
Table of contents
Other RoboVent Dust Collector manuals
Popular Dust Collector manuals by other brands

Oneida Air Systems
Oneida Air Systems Super Dust Gorilla owner's manual

SecureAire
SecureAire ACS Installation and operating guide

Oneida Air Systems
Oneida Air Systems Deluxe Dust Deputy manual

Oneida Air Systems
Oneida Air Systems V - 2000 2hp owner's manual

Delta
Delta 50-775 instruction manual

Delta
Delta 50-764 instruction manual