4-Reader Expansion Module for AC-425x-B Control Panels
Installation Manual
1
1. Introduction
The MD-D04B is an optional expansion board for use with Rosslare’s
AC-425x-B series of networked access control panels.
The expansion board adds an additional four reader or keypad inputs;
four relay outputs and four supervised inputs to the access control
panel.
As a result, an access control panel with an MD-D04B expansion can
support a total of eight readers and eight door panels. In addition, it is
possible to add any keypad or biometric reader that supports the
Wiegand or Clock & Data transmission formats.
The host access controller has complete control over the additional
readers, inputs and outputs of the MD-D04B expansion board. The
inputs and outputs can be configured using an access control software
system such as Rosslare AxTraxNG™. The software system also
configures the MD-D04B's reader card transmission format and input
connection topology.
This guide explains how to install and begin working with your new
MD-D04B access control panel expansion board.
Figure 1: MD-D04B Access Controller Expansion Board
2. Technical Specifications
2.1 Electrical Characteristics
Input Voltage 12 VDC
Input Current
(not including attached
devices))
Standby: 30 mA
Maximum: 190 mA
Number of Reader Ports 4
Number of Inputs 4
Number of Outputs 4
Output Relays 5
A with N.O., N.C., and COM contacts
Form-C relays
Inputs Voltage 5 VDC maximum voltage
2.2
6B
Input Characteristics
Input Type: Selectable as:
•Normally Open
•Normally Closed
•Supervised with one resistor (three
states, normally open or normally
closed)
•Supervised with two resistors (four
states, Normally Open or Normally
Closed))
2.3 7BPhysical Characteristics
Dimensions (L x W x D) 116 x 76 x 22 mm (4.6 x 3.0 x 0.9 in.)
Weight: 75 g (2.7 oz)
2.4 8BReader Characteristics
Reader Output Voltage: 12 VDC
Max. Reader Current: 245 mA
LED Control Output: Open collector, Active low
Tamper Input: 5 VDC maximum voltage, optical anti-tamper
sensor
Supported Formats: Various (refer to the AxTraxNG software manual)
2.5 9BLED Indicators
Power LED: Active when connected to a power source
Output LEDs: Four LEDs
Each output LED is active when an output relay is
energized and N.O. to COM contacts are shorted.
3. 2BInstallation
To install the MD-D04B expansion board:
1. Disconnect power to the access control panel before attaching the
MD-D04B.
2. Remove the MD-D04B cover by lightly pulling one of the cover
knobs away from the circuit board. The entire cover comes away
from the board.
3. Peel off the label on the cover of the panel marked "Remove to
install I/O board".
The label is located on the same side of the panel as the DIP
switch.
4. Insert the 10-pin male connector of the MD-D02B into the gap in
the panel cover labeled "IO EXPANSION SLOT".
The text on the MD-D02B must face the same way as the text on
the panel cover.
5. Tighten the screws securing the cover to the access control panel,
and the four Philips screws on the MD-D04B circuit board.
6. Replace the cover on the expansion board, using it as a guide to
ease the MD-D04B into the panel's 10-pin female connector.
2
4. Wiring Instructions
4.1 Input Wiring Options
There are six input wiring options:
Normally Open
Normally Closed
Normally Open Supervised with one or two resistors
Normally Closed Supervised with one or two resistors
Normally Open Switch
Normally Closed Switch
Figure 3 shows the normally open input connection.
Figure 2: Normally Open Input
Figure 4 shows the normally closed input connection.
Figure 3: Normally Closed Inputs
Figure 5 shows the normally open supervised input connection with
single resistor.
Figure 4: Normally Open Supervised Inputs with Single Resistor
Normally Open Supervised inputs with one resistor must be connected
with an 8.2K resistor in parallel to the input switch contacts.
Always wire resistors on the input switch and not on the
terminal block.
Figure 6 shows the normally open supervised input connection with
double resistor.
Figure 5: Normally Open Supervised Inputs with Double Resistor
Normally Open Supervised inputs with two resistors must be connected
with an 8.2K resistor in parallel and a 2.2K resistor in series to the
input switch contacts.
Figure 7 shows the normally closed supervised input connection with
single resistor.
Figure 6: Normally Closed Supervised Input with Single Resistor
Normally Closed Supervised inputs with a single resistor must be
connected with a 2.2K resistor in series to the input switch contacts.
Figure 8 shows the normally closed supervised input connection with
double resistor.
Figure 7: Normally Closed Supervised Input with Double Resistors
Normally Closed Supervised inputs with two resistors must be
connected with an 8.2 K resistor in parallel and a 2.2 K resistor in series
to the input switch contacts.
4.2 Outputs
Electrical devices can be switched using the voltage free relay contacts.
Rosslare recommends using suppression diodes for all outputs that are
connected to inductive loads and activated by DC current, such as
Magnetic Lock ("Maglock") or door strike devices.
Each suppression diode must be connected near its inductive load.
Always attach the diode's cathode to the +V terminal of the load.
Attach the diode's anode to the –V terminal.
For more information, refer to your access controller's Installation and
User Guide.
4.3 Readers
The reader terminal supports the reader's two data lines. For Wiegand
readers, these are data lines D0 and D1. For Clock & Data readers, D0
is the DATA line and D1 is the CLOCK line.
There is also support for a tamper signal input from the reader and for
one LED control output to the reader.
Proximity and keypad readers are supplied with a limited cable. The
color of the cable cover represents the cable’s function.
In general, the cable length should be no more than 150 m with an 18
AWG cable. Refer to each reader's installation guide for specific details.
Readers connected through an MD-D04B are recognized as "Reader
5",”Reader 6”,”Reader 7”, and "Reader 8" in the software system.
Figure 9 shows the wiring for Readers 3 and 4, respectively.
Figure 8: Wiring for Readers 3 and 4
5. Using the MD-D04B
5.1 Operating the MD-D04B
The access control panel detects the MD-D04B expansion board when
it powers up. When defining the panel in the access control panel's PC
application (such as AxTraxNG™), select the option designating the
panel name with a designation of “MD-D04B”.
Readers, inputs, and outputs must be defined using the access system
software. Readers connected through an MD-D04B are recognized as
"Reader 5",”Reader 6”,”Reader 7”, and "Reader 8" in the software
system.
Define each input's type and make sure the connection is compatible
with the input wiring. When selecting inputs and outputs from the
software, note that input and output type and function in the access
control software normally reflect the host access control panel's
general purpose inputs and outputs.
When using AxTrax, define input types from the "Inputs" tree menu.
Input and output functions are defined using the "Links" element
within each "Panel" tree menu item.
For more information, refer to the
AxTraxNG Software Manual
.
3 0706-0960670+00
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick
Links section on the ROSSLARE website at www.rosslaresecurity.com.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local: +1-817-305-0006
Fax: +1-817-305-0069
support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd.
22 Ha'Melacha St., P.O.B. 11407
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830
support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104
support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101
support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508
support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
sales.in@rosslaresecurity.com
CERT
ISO 9001
ISO 14001

Other Rosslare Control Unit manuals

Rosslare AC Series Operating instructions

Rosslare

Rosslare AC Series Operating instructions

Rosslare AC-215 Assembly instructions

Rosslare

Rosslare AC-215 Assembly instructions

Rosslare AC-S73 User manual

Rosslare

Rosslare AC-S73 User manual

Rosslare AC-C31V User manual

Rosslare

Rosslare AC-C31V User manual

Rosslare AC-C31 User manual

Rosslare

Rosslare AC-C31 User manual

Popular Control Unit manuals by other brands

Festo CPE-10-PRS series operating instructions

Festo

Festo CPE-10-PRS series operating instructions

Honeywell Gamewell FCI Velociti Series Installation and maintenance instructions

Honeywell

Honeywell Gamewell FCI Velociti Series Installation and maintenance instructions

VAT 642 Series Installation, operating,  & maintenance instructions

VAT

VAT 642 Series Installation, operating, & maintenance instructions

schmersal SRB 401EM-115V operating instructions

schmersal

schmersal SRB 401EM-115V operating instructions

Lenze 2173 manual

Lenze

Lenze 2173 manual

Abocom WM5208 user manual

Abocom

Abocom WM5208 user manual

M-system R7D-YS2 instruction manual

M-system

M-system R7D-YS2 instruction manual

Hioki LR8450 instruction manual

Hioki

Hioki LR8450 instruction manual

Honeywell ADEMCO VA8201 Installation and setup guide

Honeywell

Honeywell ADEMCO VA8201 Installation and setup guide

sauermann Si-PRO-DP-50 quick start guide

sauermann

sauermann Si-PRO-DP-50 quick start guide

LEF LIGHTING NEXTA MCU-M500 instructions

LEF LIGHTING

LEF LIGHTING NEXTA MCU-M500 instructions

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Grosvenor RM-ICLSE-IT/RS instruction manual

Grosvenor

Grosvenor RM-ICLSE-IT/RS instruction manual

Moxa Technologies CA-134I Quick installation guide

Moxa Technologies

Moxa Technologies CA-134I Quick installation guide

FP InovoLabs X500 Hardware manual

FP InovoLabs

FP InovoLabs X500 Hardware manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.