ROXX CLUSTER B4 W User manual

User
Manual
CLUSTER B4 W
USER MANUAL

2
User
Manual
User
Manual
CONTENT
1. Safety Informations
1.1. General Preventive Measures 4
1.2. Regulations for equipment that connects to power mains 5
1.3.Technical warnsigns and explanation 6
2. Introduction
2.1. About us 7
2.2. CLUSTER B4 W 7
3. General Product Information
3.1. Scope of delivery 8
3.2. Control Functions 8
3.3.Features 8
4. Installation & Setup
4.1 Physical Installation and Rigging 9
4.2 Connections 14
4.2.1. AC Power 15
4.2.2. DMX Connection 15
4.2.2.1. Cable Connection 15
5. Operation
5.1 Start up 16
5.2 Control Display 16
5.3 Display Short Cuts 16
5.4 Conguration 18
5.4.1 Set DMX Start Address (Direct Access) 18
5.4.2 Selecting DMX Mode 18
5.4.3 Stand Alone 19
5.4.4 Slave Mode 21
5.4.5 Settings 21
5.4.6 System Info 25
6. Accessories
6.1 Accessories 26

3
User
Manual
User
Manual
7. Technical Data / Diagrams
7.1 Technical drawings and measurements 27
7.2 IP Rating 28
7.3 Technical Data 29
7.4 DMX-Charts 31
7.5 RDM Templates 39
8. Troubleshooting 41
9. Manufacturer´s Declaration 42

4
User
Manual
1. SAFETY INFORMATION
1.1. General Preventive Measures
1.1.1. Please read, understand and follow the instructions.
1.1.2. Store the instructions and information in a safe place.
Best solution is the ring binder provided by ROXX.
1.1.3. Follow all safety warnings. Under no circumstances remove safety warnings
or other information from the equipment.
1.1.4. Don’t use the equipment for any other intended purpose or manner.
1.1.5. Use only stable and compatible stands and/or brackets. Especially when x installed.
Make sure the wall brackets are properly installed and safe. Make sure the device is securely
installed and cannot fall.
1.1.6. Check the safety regulations applying for your country before and during installation.
1.1.7. Keep the device away from heat! Don’t place/install near heaters, ovens or any source of heat.
Make sure that the device always is efciently cooled and cannot overheat.
1.1.8. Always guarantee that ventilation and cooling slots are clean and not blocked.
1.1.9. Item must be away minimum 20cm from anything around and above it.
1.1.10. Do not use this device close to water.
1.1.11. Do not expose this equipment to ammable materials.
1.1.12. Make sure that no objects can fall into the device.
1.1.13. Only use this device with the accessories recommended by the manufacturer.
1.1.14. Always check the equipment for housing damages, so that no water can enter the device.
No containers containing liquids of any kind should be place on top of the unit.
1.1.15. Opening or modifying this device is only allowed by authorized and qualied persons.
1.1.16. All cables need to be checked after connecting the device in order to prevent damage or accidents.
1.1.17. Make sure that the device is transported safe and packed proper in order to prevent damage of any kind.
1.1.18. Once you notice improper function of your device due to damage, electric shock or anything similar,
immediately unplug the unit from the mains outlet and contact our service department.
1.1.19. Clean the device with a dry cloth.
User
Manual

5
User
Manual
1.1.20. Observe all disposal laws applicable in your country. Especially for the packaging.
1.1.21. Plastic bags are not a toy! Keep away from children!
1.1.22. Please note that changes or modications which are not approved by the party responsible
for compliance will void the user’s authority to operate the device.
1.2 Regulations for equipment that connects to power mains
1.2.1. If an earthing contact is available in the used power cord, it must used in combination
with an power outlet, providing a protective ground. In no circustances should the protective
ground be deactivated.
1.2.2. Do not switch on the device immediately after it has been in strong different temperatures,
especially after transport. Let the device acclimatize to the temparature in the room of usage
rst to prevent moisture and condensation.
1.2.3. Verify that the correct voltage and frequency are available in the area of operation, before
connecting the unit to the mains outlet.
1.2.4. If the plug doesn‘t t in your mains outlet, contact your electrician.
1.2.5. Make sure your power cord/adapter/connector does not show signs of kinks/warps or is being
stepped on.
1.2.6. Allwas disconnect the unit when not in use or being cleaned. Don‘t pull on the cord to disconnect.
Only touch power connections with dry hands!
1.2.7. Don‘t switch the unit on/off rapidly. This may cause damage.
1.2.8. If a fuse needs to be replaced, ALWAYS make sure that exact the same fuse will be used
(type and rating). Repeatedly blown fuses need to be checked by an authorised service technician.
1.2.9. In the risk of lighting strike all units need to be unpluged from the mains in order to prevent damage.
1.2.10. During installation there must be a voltage free condition.
1.2.11. The device needs to be cleaned and serviced regularly and will credit this with a longer life cycle.
Dust, dirt, moist, water, smoke, nicotine or anything similar inside the unit will cause
damage/malfunction.
1.2.12. The unit needs to have at least 0,5m distance to anything ammable.
1.2.13. You have to make sure that any electrical installation applys to the laws of your country.
Correct power cables and applying standards have to be used.
User
Manual

6
User
Manual
1.3. Technical warnsigns and explanation
In order to prevent the risk of an electric shock, under no circumstances remove the cover/back
or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs
should only be done by qualied service personnel or the manufacturer.
Dangerous uninsulated voltage inside the device can cause an electrical shock when opened by
unqualied personnel.
Important operating and maintenance instructions apply!
Do not operate this device in tropical climates.
CAUTION! Intense LED light source! Risk of eye damage. Do not look into the light source
The housing surface of the spotlight can heat up to temperatures as high as 70 °C in regular use. Ensure
that it is not possible to come into contact with the housing unintentionally. Always allow sufcient time
for the lamp to cool down before dismantling, carrying out maintenance work or charging etc..
IMPORTANT IMFORMATION!
• This is a product which has been developed for professional usage
in event technology. It is not suitable as a houshold lighting.
• NEVER stare, not even temporarily, directly into the light source.
• Don‘t use magniers or any other optical instrument to look at the beam.
• The effects of this device, expecially the stroboscope effect, can cause
problems for sensitive people or may even cause epileptical seizures.
User
Manual

7
User
Manual
2. INTRODUCTION
2.1. About us
The name ROXX®came easily.
Combined with the concentrated knowledge and many years of experience, our three founders, who have been
leaving their mark in the event and lighting industry for many years already, came together in 2020 to start this
outstanding venture.
Product development, sales and marketing as well as the exceptional know-how and the profound rooting in the
eld of the professional lighting technology belong to our core competences and therefore guarantee extremely in-
novative and reliable products, excellent support and professional service in every aspect.
Designed & developed in Germany
ROXX®products are developed and designed in Germany. Always in tight consultation with our customers and
experts who will eventually be working with these tools. This ensures innovative, easy-to-use and performance-
oriented solutions, which provide added value for our customers.
Made to last
Recommended for permanent outdoor use, most ROXX®products feature additional corrosion protection and en-
hanced IP66 equipment protection, thereby providing that crucial extra for a wider range of applications. In addition
to architectural or theme park applications, even xed installations in coastal or offshore areas with high salt expo-
sure can be reliably implemented over long periods of time.
2.2. CLUSTER B4 W
All CLUSTER products can be easily connected both horizontal and vertically, by using the integrated C-Lok system.
The series is made to enable toolless multiple array con gurations, scalable from a single vertical line, to massive
matrix like arrays. Due IP65 rating all products are outdoor ready and protected from ingress of dust and rain. There
are several mounting options – Camlock mounts on top and back enable the use of Omega-Brackets, Yokes can be
attached to mounting points on all sides, or the internal C-Lok system can be used for seemless interconnection.
Pre-Link Magnets on top and side help to allign the xtures, giving an incredible user-friendly operation and save
interlocking. A specially designed rigging bracket is used for seemless connection of multiple Blinders, to avoid gaps
due to bracing of the truss structure by variable, sliding mounting positions. Floor extensions can be used to create
vertical structures in single or double rows.
In the warmwhite versions, an emulated ´shift to warm´ warms the color temperature of the light as it dims. To de-
liver a perfect classic tungsten look, Amber and Red LED´s are mixed with the highpower warmwhite LED´s when
decaying.
User
Manual

8
User
Manual
3. GENERAL PRODUCT INFORMATION
3.1. Scope of delivery
1x CLUSTER B4 W
Power cord with plug (EU country specic, if not ordered differently)
Pre-installed PUK
We´re offering a wide range of professional accessories (optional). Please see under menu 6 or at our website
www.roxxlight.com
3.2. Control Functions
• 1CH DWE, 2CH DWE, 4-1CH DWE, 4-2CH DWE, 7CH STROBE, 9CH STANDARD, 12CH EXTENDED
17CH EXTENDED
• RDM (Remote Device Management)
• Stand Alone Functions including auto programs and Quick Light.
• Master & Slave
3.3. Features
User
Manual

9
User
Manual
Closed
Open
4. INSTALLATION & SETUP
4.1 Physical Installation and Rigging
ROXX CLUSTER B4 W may be installed in any orientation. For this purpose the product provides several options:
Standing:
The xtures Yoke includes two M8 inner threads to install the optional ROXX YOKE FLOOR EXTENSION.
Hanging:
The xture can be installed in different ways:
1. Directly by integrated 1/4 turn Camlocks on top- or rear side
User
Manual
Omega Bracket ST

10
User
Manual
2. By included yoke with several mounting points:
Multiple mounting points:
A: 3x Camlock with ¼ turn adapters
B: 3x M12 / ½“
C: 1x TV Spigot
Additional Yoke anchor points:
In the delivery state, the yoke is preinstalled in such a way that the individual eyes can be rotated +/-20° in the pan.
Each CLUSTER device also provides side anchor points for the yoke so that the device can then be rotated either
clockwise or counterclockwise so that the individual eyes can then be adjusted +/-20° in tilt movement.
In addition, the B4 W and B4 FC models offer a third, lower anchor point that can be used to mount the optional
YOKE 4.3 to optimize the center of gravity on, for example, a 6-lite or 8-lite.
Attention!
This should only be used when clustering several units together, as otherwise the center of
gravity of the individual unit is no longer in the middle and the unit can unintentionally tip over
when the yoke is released.
User
Manual
B
A
C

11
User
Manual
3. Using optional ROXX RIGGING BRACKET
For seemless connection of multiple Blinders, to avoid gaps due to bracing of the truss structure by variable, sliding
mounting positions.
Product Clustering
All CLUSTER products can be easily connected both horizontal and vertically, by using the integrated
C-Lok system. The series is made to enable toolless multiple array congurations, scalable from a
single vertical line, to massive matrix like arrays.
To connect the devices with each other, proceed as follows in sequence:
1. Bring the devices together with the respective top and
bottom side.
A so-called centering puk is pre-installed on the top of
every cluster device.
This should always be installed when connecting the de-
vices to each other.
2. Pre-Link Magnets on top and side help to allign the x-
tures due cluster process and giving support operation
for convenient and save interlocking.
Important Note:
Even though the pre-link magnet system
is strong enough to hold the devices to-
gether, at least one hand must always
remain on the device for support during the connection.
User
Manual

12
User
Manual
3. Make sure that the C-Lok hooks are turned counterc-
lockwise (CCW) to the end-position rst before you nally
lock the C-Loks.
4. For locking all C-Lok´s, please turn them clockwise into
end-position.
Note:
As soon as both dot indicators are in line, the C-Lok is
securely locked
Maximum Tensile and Torsion Load
Before setting up Cluster congurations, be aware of the maximum tensile and torsion load, listed
here below. Also make sure the mounting clamps are capable of supporting the total weight of your
conguration.
The different rigging options of all Cluster products result in different maximum tensile and torsion loads that must
not be exceeded for a safe overhead installation.
The maximum loads listed here below take into account the 10-fold safety!
1. Rigging by integrated 1/4 turn Camlocks on top- or rear side
User
Manual
Max. Tension Load: 90kg
Max. Torsion Load: 14.500 Nmm
Max. Tension Load: 90kg
Max. Torsion Load: 6.700 Nmm

13
User
Manual
2. Rigging by Yoke with multiple mounting points
3. Using optional ROXX RIGGING BRACKET with 2x Mounting Clamps
User
Manual
a. With 1x Mounting Clamp
Max. Tension Load: 62kg
Max. Torsion Load: 4.280 Nmm
c. With 1x Omega Bracket
Max. Tension Load: 49kg
Max. Torsion Load: 5.041 Nmm
Max. Tension Load: 72kg
Max. Torsion Load: 6.326 Nmm
b. With 2x Mounting Clamp
Max. Tension Load: 90kg
Max. Torsion Load: 9.096 Nmm
b. With 2x Omega Bracket
Max. Tension Load: 90kg
Max. Torsion Load: 10.808 Nmm

14
User
Manual
Important Note:
Please be aware of using the centering PUK for safe RIGGING BRACKET installation to the
CLUSTER device.
4.2 Connections*
A: Mains In: IP65 Power input connector with rubber sealing
cap.Connect using the provided power cable
(when not in use,
always close with rubber sealing cap).
B: Mains Out:
IP65 Power output connector with rubber
sealing
cap. Provides power to additional xtures. Ensure that the to-
tal power consumption of all daisy-chained devices connec-
ted do not exceed 8A (Ampere)! (when not in use, always close
with rubber sealing cap).
C: DMX IN: Male IP65 5-pin XLR connector (when not in use,
always close with rubber sealing cap).
D: DMX OUT:
Female IP65 5-pin XLR connector
when not in use, always close with rubber sealing cap
).
E: GoreTex
F: Safety Eyelet
G: IP65 USB port for rmware updates
*Note:
In order to provide protection from spraying water, in accordance with protection class IP65, special IP65-
rated XLR connectors must be used correctly with the DMX input and output sockets, or they must be closed
using the rubber sealing caps. When connected correctly, or when sealed correctly with the rubber sealing
caps, the POWER IN and POWER OUT sockets are protected from spraying water, as in accordance with IP65.
User
Manual
A
D
C
G
FF
E
B

15
User
Manual
4.2.1. AC Power
The CLUSTER B4 W operates on any 100–260 V, 50/60 Hz AC mains power supply with a maximum power con-
sumption of 220W.
Connect the xture to AC power using the supplied cable or a similar one with Neutrik powerCON TRUE1 NAC3FX-W
or a compatible type, to ensure the correct ingress protection (IP).
For temporary installations, the mains cable must be tted with a grounded connector intended for exterior use. The
xture must be grounded/earthed and be able to be isolated from AC power. The AC power supply must incorporate
a fuse or circuit breaker for fault protection.
Warning!
Read “Safety Informations” starting on page 3 before connecting the xtures to AC mains power!
Do not connect the xture to an electrical dimmer system, as doing so may cause damage that is not
covered by the product warranty!
4.2.2. DMX Connection
The
CLUSTER B4 W
is fully controllable by DMX (USITT DMX512-A standard, based on RS-485) and RDM.
4.2.2.1. Cable Connection
If using a cabled DMX system, connect the DMX IN cable to the input connector (male 5-pin XLR connector) and
DMX OUT cable to the output (female 5-pin XLR connectors).
For outdoor installations, use only IP65-rated XLR connectors.
Use shielded twisted pair cable designed for RS-485 devices. The cables are daisy chained between the xtures,
and up to 32 xtures can be connected to the same DMX link. Up to 300 meters (1000ft.) of cable is achievable with
high quality DMX cables. All DMX links must be terminated in the last xture by connecting a DMX termination plug
to the last xture’s 5 pin DMX out connector.
Standard microphone cable is not suitable for transmitting DMX.
Wire Color (EU models) Wire Color (US models) Conductor Symbol
Brown Black Live L
Blue White Neutral N
Yellow / Green Green Ground (earth) or
1DATA
GND
DMX Termination
on last xture DMX out
DATA -
DATA +
120 Ohm
+/- 5%
5
2 4
3
1DATA
GND
XLR pin out
DATA -
DATA +
5
2 4
3

16
User
Manual
5. OPERATION
5.1 Start up*
Once the xture is connected to AC power, the boot process starts and the following information will appear on the
display:
“Ready to ROXX”, the product name and the current software version.
After this process, the xture is ready for operation, and starts in the previous-
ly enabled mode.
*Note:
During boot process the fan spins up quickly to blow out some possible
dust from last use.
5.2 Control Display*
OLED Display with Touch-Sensitive controls
Press ENTER to access the selection menu for system settings or conrm changes.
Press ESC to take a step back in the menu.
Press arrows to scroll up and down inside the menu and change values, such as DMX address.
*Note:
For a smooth navigation thru the menu settings, please make sure the display surface is dry and dust free.
After approximately 1 minute of inactivity inside the menu settings, the display will automatically jump back
to home screen.
5.3 Display Short Cuts*
Short Cuts
For some always recurring functions the xture allows quick and user-friendly access at home screen over some dis-
play control short-cuts:
User Reset or Factory Reset*
Pressing ESC+ENTER simultaneously a Factory Reset or User Reset can be started.
By using the up/down arrows the Factory- or User Reset can be selected.
For conrming press ENTER, to jump back please press ESC.
*Note:
After Factory Reset all xture settings are set back to factory default values.
After User Reset all user selected reset functions and user default values will set back.
Also a short self-test will start immediately while dimming in and out each single color.
User
Manual
ESC
ENTER ESC
+
ENTER

17
User
Manual
Display Off
Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off
immediately. Once a control is pressed the display backlight will turn on.
Manual display ip function*
The xture includes an auto display ip function by default.
To use the manual display ip function please disable the auto ip function under Settings / Display rst. Once the
auto display ip function is disabled you can use the manual display ip function by pressing arrow up + arrow down
simultaneously. The display will rotate 180. By pressing both arrows simultaneously again the display will ip back.
*Note:
Once the display is ipped both Up / Down controls will work according to the display rotation.
Quick Light function
(hold 3 seconds)
For easy and fast operation during setting the lights the xture includes a user-friendly Quick Light function. If DMX
is not assigned please press and hold ENTER for 3 seconds at homescreen, after the Quick Light function will appear.
Here dimmer can be adjusted from 0-100% by using up/down arrows, to take over the dimming value please press
ENTER to conrm.
User
Manual
ESC
ENTER
+
+

18
User
Manual
5.4 Conguration
Home Screen
After boot process the xture is ready for operation and starts in the previously enabled mode. At home screen the
following information will appear, depending on the current operating mode:
A
DMX Adress
B
Operating Mode (DMX Mode, Quick Light or Standalone Mode)
C
Next available DMX address depending on the xtures DMX footprint
D
External Data protocol (DMX).
E
The dot indicates the active protocol
5.4.1 Set DMX Start Address (Direct Access)
At Home Screen the DMX address can be changed directly by using the up and down arrows. During this process the
DMX address starts blinking, once it´s conrmed by pressing ENTER it stops blinking.
If the DMX address will not be conrmed by ENTER within 10 seconds, the display will jump back and show the DMX
address from before and stops blinking.
5.4.2 Selecting DMX Mode*
At home screen please press ENTER to access to the main menu (level 1).
While using UP / DOWN arrows, please select the menu item “DMX Mode” and conrm
by pressing ENTER.
In the following sub-menu (level 2), you can now choose between 8 different DMX operating modes while using the
UP/Down arrows and conrm by pressing ENTER or jump back by pressing ESC.
After conrmation the display will jump back to main menu (level 1). Press ESC for homescreen, here the selected
DMX mode will be displayed.
*Note:
For detailed information about the several DMX modes including channel assignment please see our DMX
Control chart.
.
User
Manual
9 CH
STD Next
( 10 )
•DMX
1
B
A
C
D
E

19
User
Manual
5.4.3 Stand Alone*
Press ENTER to access to main menu (level 1).
While using the UP / DOWN arrows, please select the menu item “Stand Alone” and conrm
by pressing ENTER.
In the following sub-menu (level 2), you can now choose between 2 different Stand Alone operating modes (Auto,
Quick Light), Stop Stand Alone while using the UP/Down arrows and conrm by pressing ENTER or jump back by
pressing ESC.
To nally use Stand Alone programs please make sure DMX is disconnected to the xture, as this protocol has priority.
Stop Stand Alone
To stop a running Stand Alone mode immediately, please select “Stop Stand Alone” and conrm by pressing ENTER.
The display will automatically jump back to level 1.
Auto*
Select “Auto” by using the up/down arrows and press ENTER.
Here at sub-menu (level 3), you can choose between 5 different Auto Effects (Effect 1 - 5
) and Stop Program.
Using
the Up/Down arrows you can select one of the 5 Effects and conrm by pressing ENTER or step back by ESC.
After conrming your preferred Effect, you can now adjust speed and brightness at level 4.
To adjust speed, please use the UP / DOWN arrows to select the menu item “Speed”, and conrm with ENTER. After
use UP / DOWN arrows to adjust the speed value between 000-100 and conrm by ENTER or jump back by ESC.
To adjust brightness please select “Dim” as per the procedure previously described and conrm with ENTER. After
use UP / DOWN arrows again to adjust the brightness value between 000-100 and conrm by ENTER or jump back
by ESC.
User
Manual
Menu
Level 1
DMX Mode
Stand Alone
Slave
Settings
System Info
DMX Mode
Level 2
1CH DWE
2CH DWE
4-1CH DWE
4-2CH DWE
7CH STROBE
9CH STANDARD
12CH EXTENDED
17CH EXTENDED
Menu
Level 1
DMX Mode
Stand Alone
Slave
Settings
System Info
Stand Alone Mode
Level 2
Stop Stand Alone
Auto
Quick Light

20
User
Manual
Once it´s conrmed or denied the display will automatically jump back to level 3.
To stop running a selected Effect please chose “Stop Program” at level 3 or "Stop Stand Alone" at level 2.
For returning back to homescreen please press ESC three times.
At homescreen the selected Stand Alone mode “Auto” and the selected program will be displayed.
*Note:
Using arrows UP /DOWN at homescreen Auto programs can be directly changed according to the list.
Quick Light*
The standalone mode “Quick Light” allows a direct adjustment of the single eyes brightness and dimmer
and shutter.
To adjust your Quick Light please press ENTER to access to main menu (level 1).
While using the UP / DOWN arrows select the menu item “Stand Alone” and conrm
by pressing ENTER. After please select the item “QuickLight” by using the up/down arrows and press ENTER again.
Using UP and DOWN controls, select your desired color and conrm with ENTER.
After you can adjust the brightness for each eye between 000-255 and conrm by ENTER.
Besides the individual color mix also a master dimmer can be adjusted between 000-100.
For strobe effects please adjust the Shutter value between 000-255.
*Note: Please see detailed explanation for strobe effects inside DMX chart at the end of this manual.
Using UP/DOWN arrows at homescreen you can change Quick Light dimmer value.
User
Manual
Effect 1
Auto
Menu
Level 1
DMX Mode
Stand Alone
Slave
Settings
System Info
Stand Alone Mode
Level 2
Stop Stand Alone
Auto
Quick Light
Auto
Level 3
Stop Program
Effect 1
Effect 2
Effect 3
Effect 4
Effect 5
Program
Level 4
Speed <0-100>
(Default 50)
Dim <0-100>
Menu
Level 1
DMX Mode
Stand Alone
Slave
Settings
System Info
Stand Alone Mode
Level 2
Stop Stand Alone
Auto
Quick Light
Quick Light
Level 3
Dimmer <0-100>
Shutter <0-255>
(Default 20)
LED 1 <0-255>
LED 2 <0-255>
LED 3 <0-255>
LED 4 <0-255>
Table of contents
Other ROXX Lighting Equipment manuals