10. TRANSPORT AND STORAGE
Transport and storage should only be performed by specialist personnel in accordance with the assembly and opera-
ting manual and regulations in force.
e following points should be noted and followed:
■Check the delivery according to the delivery note to ensure it is complete and correct and check for any damage.
Any missing quantities or damage incurred during transport should be confirmed by the carrier. No liability is accep-
ted if this is not observed.
■For weight see technical data
■It should be transported with suitable lifting equipment in the original packaging or on the transport equipment
indicated.
■If transported with a forklift, it should be ensured that the product is resting with the basic profile or base frame
completely on the forks or on a pallet and the product‘s centre of gravity is between the forks.
■e driver must be authorized to drive a forklift.
■Do not go beneath the suspended load.
■Avoid damage or deformation of the housing.
■e product must be stored in a dry area and protected from the weather in the original packaging. Open pallets
should be covered with tarpaulins. Even weatherproof modules should be covered because their weather resistan-
ce is only guaranteed after complete installation. If moisture has penetrated into the original packaging, remove it
immediately.
■Storage temperature between +5 °C and +40 °C. Avoid severe temperature fluctuations.
■If the product has been in storage for more than a year, check the smooth running of impellers and valves by hand.
11. ASSEMBLY
Assembly work may only be performed by specialist personnel in accordance with the installation and operating ma-
nual and the regulations and standards in force.
e following points should be noted and followed:
■e foundation must be even and levelled. It must not exhibit unevenness or a slope in any direction.
■Set up and align the machine with the aid of a water level. A perfect function of the device can be guaranteed only
if levelled mounted.
■Only suitable installation aids, in accordance with regulations, should be used.
■e device must be installed in such a way that it is easily accessible for maintenance and cleaning purposes.
■e unit should only be installed with authorized and suitable fastening materials at all fastening points.
■Do not distort the unit when installing.
■Just use the indicated mounting and fixing places. No holes should be made in the housing or any screws screwed
into it.
■e duct system must not be supported on the housing.
■For structure-borne sound decoupling, a flexible connection is recommended when connected on a duct system.
Lift the roof fan out of the packaging:
■Insert crane hook (1) into the two
eyehooks (2) on the roof fan
■Release transport locks (3) 4x
■Lift the roof fan (4) out of the packa-
ging (see Fig.)