Saje AROMA ELEVATE User manual

1
ultrasonic diuser
diuseur ultrasonique
Please read and save this manual
AROMA ELEVATE

Infuse your air with the vitality
and well-being of nature
ultrasonic diuser
diuseur ultrasonique
AROMA ELEVATE


TABLE OF CONTENTS
1
2
3
5
6
9
11
14
16

1
BENEFITS OF DIFFUSING
Diffusing is an easy, heat-free way to enjoy Saje’s 100%
natural diffuser blends.
This ultrasonic technology, combined with water and
essential oils, produces negative ions and aromas that
elevate your well-being.
When used with your favorite Saje diffuser blend, the
ultrasonic diffuser’s refreshing mist brings nature’s
goodness into your space, supporting balance and harmony.
Transform your surroundings with revitalizing air
that’s reminiscent of fresh mist off a waterfall. Add
the Saje diffuser blend of your choice and enjoy fresh,
inviting aromas any time.

2
PRODUCT FEATURES
Uses an ultrasonic, heat-free system to disperse
essential oil molecules into the air.
Gently humidifies your space.
Whisper-quiet operation and auto shut-off.
Continuous and intermittent mist output settings.

3
SPECIFICATIONS
product name Aroma Elevate
input voltage AC110-240V
output voltage DC24V
rating power 9W max.
water tank capacity 4.7 fl oz | 140 ml
misting duration
approx. 5 hours continuous;
approx. 10 hours intermittent
(30 sec on/30 sec off)
mist output
approx. 0.8 fl oz/25 ml per
hour on continuous;
approx. 0.4 fl oz/12.5 ml per
hour on intermittent
settings on; continuous mist or
intermittent mist; off
coverage area approx. 500 sq ft

4
dimensions
approx. (L) 112mm x (W) 104mm
x (H) 190mm or (L) 4.40” x (W)
4.09” x (H) 7.48”
net weight approx. 32.5 oz | 921 g
main materials outer cover: cement;
water tank: PP

5
DIAGRAM OF PARTS
.
.
.
.
.
.
.
.
.
.
.

6
OPERATING INSTRUCTIONS
1. Remove the cement cover from
the unit to expose water tank.
2. Connect power adaptor to DC
power jack underneath unit.
3. Fill water tank with room
temperature tap water to
no higher than max. water
level line (4.7 fl oz | 140 ml) by
bringing water to the unit.
4. Add 10-15 drops (depending on
preference) of your favorite Saje
diffuser blend to the water. Tilting
the unit can cause water to run
into the diffuser’s ventilation
system and out the bottom — to
ensure correct usage, always bring
water to your ultrasonic diffuser
and not the other way around.

7
5. Replace the cover and ensure that
it fits properly onto unit.
6. Plug power adaptor into
electrical outlet.
7. Press the power button of the
unit to turn on. Press once to mist
continuously, twice for intermittent
and a third time to turn the unit off.
button indicators:
press once:
Continuous mist
press a second time:
Intermittent
press a third time:
Mist o

8
8. Unit will shut off automatically when low level
of water is detected. Note that the water level
remaining in the tank after shut-off will vary. For
next use, fill up water level to the max. water level
line with new water supply.
9. A filled unit should never be moved. Always wait
until water reaches minimum levels to change
diffuser’s location; this will deter water from
entering the ventilation system.
10. Use only Saje diffuser blends; other oils may
contain fragrances, base oils or synthetics that
could result in malfunction. Some single note
essential oils are also too thick or heavy for use
in the ultrasonic diffuser. See FAQs for more
information.
please note: run times and amount of water left in
the tank after auto shut-off will vary due to climate,
environment and other factors.
for optimal operation, ensure mist is unobstructed by
overhanging objects.

9
CARE & MAINTENANCE
If the unit is knocked over while in operation, water
could leak into the internal mechanism of the unit; if
this occurs, unplug from power, empty water and let unit
dry out in well-ventilated area for at least three days.
Turn off unit and unplug from the power adaptor prior
to cleaning.
Remove cover and empty water from the water tank,
carefully avoiding the air outlet.
To clean exterior of unit, wipe outer lid with a dry cloth.
Do not allow essential oils to spill on outer lid.
Clean inner lid with a damp cloth. Do not submerge or
wash entire lid under water.
If oils are spilled on the diffuser’s surface, clean
immediately to prevent surface damage.
Frequency of water tank necessary cleaning is depend-
ent upon usage and types of diffuser blends used (i.e.
how thick the essential oils are in the diffuser blend).

10
To clean inside water tank, pour a few drops of rubbing
alcohol into tank and wipe with a clean, soft cloth.
To clean the disc, pour a few drops of rubbing alcohol
onto a clean cotton swab and wipe the disc. The disc
can be accessed by inserting the swab in the hole at the
center/bottom of the water tank. Repeat this process
with a new cotton swab until the cotton swab comes
out clean.
The ceramic disc should be kept clean of mineral
deposits and other debris for optimal misting. Never
use any sharp objects to clean the ceramic disc as this
will damage the disc permanently.
For optimum results, clean the water tank before
changing diffuser blends.
Do not disassemble or attempt to repair unit; in the
event of a problem, please contact 1-877-A SKSA J E.

11
CAUTIONS
Only use the power adaptor supplied with the
device. Never operate the device if the power
adaptor is damaged.
Do not attempt to use the device if any part is
damaged or broken.
To reduce the risk of electric shock: do not attempt to
service the device in any way other than as described
in the “Care & Maintenance” section of this manual;
do not plug the unit into the wall socket with wet
hands. In case of smoke, unusual aromas, noises or
other malfunctions, unplug the unit immediately
and discontinue use.
Do not place unit directly below or beside electrical
outlets or other electrical devices that are
susceptible to water damage.
Do not place the unit on carpet or fabric surfaces
that may obstruct the fan on the bottom of the unit,
causing overheating.

12
To prevent mist from settling on the top of the diffuser,
ensure the unit is placed in an appropriately-sized space
with good airflow.
When moving the device, hold securely by the base.
Always place the unit on a stable, level surface. Do not
tilt, move or attempt to empty or refill unit while in use.
Do not touch the highly sensitive ceramic disc with
bare fingers when the ultrasonic diffuser is in use or
plugged in. To prevent clogging or damaging the ceramic
disc when operating, use clean tap water at room
temperature.
Do not fill water tank directly from tap as water could
spill into the internal mechanism and cause damage.
Fill only to the water level line and do not overfill or
immerse the unit in water.
Do not pour water or other liquid into the air outlet.
Ensure that no essential oils or water leak into the air
outlets on either side of the water tank. After each use,
remove any liquid left in the water tank.
Always turn off and unplug the device during

13
maintenance or when not in use. Ensure that the power
adaptor is not covered or blocked when plugged in; it
must be able to dissipate the heat properly.
Never leave diffuser unattended while turned on,
especially in children’s rooms. Keep device out of
child’s reach.
Use only Saje diffuser blends in device: other oils may
contain fragrances, base oils or synthetics that could
result in malfunction. Some single note essential
oils are also too thick or heavy for use in the ultrasonic
diffuser. See FAQs for more information.
Always keep unit out of reach of small children and pets.
Lid is made of fragile materials and can be easily scuffed
or damaged if dropped. Handle with care.

14
FCC & IC STATEMENTS
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
. This device may not cause harmful interference,
and
. This device must accept any interference received,
including interference that may cause undesired
operation.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause
harmful interference to radio or television reception, which
can be determined by turning the equipment off and on,

15
the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
Saje Natural Wellness Canada could void the user’s
authority to operate this equipment.
This device complies with Part 18 of the FCC Rules and ICES 001.
Although this product is tested and complies with FCC, it
may interfere with other devices. If this product is found
to interfere with another device, separate the other device
and this product. Conduct only the user maintenance
found in this instruction manual. Other maintenance and
servicing may cause harmful interference and can void the
required FCC compliance.

16
FAQs
q: what if my unit does not turn on?
The power adaptor may not be properly plugged in;
ensure that the power adaptor is properly plugged
into the DC power jack and the electrical source.
q: what if my unit does not mist or there is almost
no mist?
. There may not be enough water in the water tank;
ensure that the water tank is filled to the maximum
water level line.
. The water level may be too high (higher than the
maximum water level line); turn off unit, pour out
excess water and try again.
. The ceramic disc may require cleaning. Please see
“Care & Maintenance” instructions.
Other Saje Spa Accessories manuals