TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
2
4
6
8
10
Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.saluslegal.com
RT510 / RT510TX / RT510RF is a programmable room thermostat used to control room temperature.
Device launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510 / RT510TX Thermostat RXRT510 Receiver
1
67
89
4
3
2 5
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
RT510 Thermostat RT510TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs
Voltage free
NO / COM / NC
terminals
-
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Hysteresis ±0.25°C or ±0.5°C ±0.25°C or ±0.5°C
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: [email protected]
E: [email protected]
SALUS Controls is a member of the
Computime Group.
Maintaining a policy of continuous product
development SALUS Controls plc reserve
the right to change specification, design and
materials of products listed in this brochure
without prior notice.
RT510, RT510TX, RT510RF
DIP Switch Settings
RT510 Wiring diagram
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510TX Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
NO COM L N
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
Programming - automatic mode
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
2
4
6
8
10
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). To do this, rstly choose programming mode:“5-2” (business days + weekend) or“24h”(each
day separately) using parameter d04 from Installer mode. Programmed schedules should use all
time periods.
The DIP Switches can be found on the rear of your thermostat.
Control feature TPI Span
Operation When TPI is selected on DIP
switch № 2, the DIP switch №
1 is functional. You can choose
the Cycles Per Hour between
a lower comfort level (6CPH)
and a higher comfort level
(9CPH).
When Span is selected
on DIP switch № 2,
the DIP switch № 1 is
not functional. The
temperature accuracy of
your thermostat is set to
± 0.25 °C.
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
MON
TUE
WED
THU
FRI
SAT
SUN
MON MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
THU
THU THU
MONMON
MON
MON
MON
www.salus-tech.com
Issue Date: February 2018
V028
For PDF Installation guide please go to
www.salus-manuals.com
Quick Guide
868.0-868.6MHz; <13dBm
Temporary Override mode
Hourly temperature Override Mode (+Hr)
RT510TX thermostat pairing with the receiver Installer mode
Reset of the RT510 thermostat
Reset of the RT510TX thermostat
Manual Mode and setting setpoint temperature
Frost Protection
Sleep mode
Holiday Mode
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
2
4
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
1
3
Using or button set a new setpoint
temperature for override.
Using or buttons set new setpoint
temperature.
Press three buttons at the same time
for 3 seconds.
Use or button to set the number
of days for Holiday Mode.
Using or buttons set new setpoint
temperature.
Press +Hr button to set number of hours for
temperature override (e.g. to set up override
for 3 hours, press the button 3 times).
Press the + Hr button until number of hours
disappears from display.
Press button to activate the Manual Mode.
Hold down button for 3 seconds
to activate the Holiday Mode.
Press button to turn On Frost
Protection mode.
Press button again to turn
O Frost Protection mode.
Press SET button
to conrm.
Press SET button to conrm.
You can set up to 31 days.
Using SELECT button choose the parameter.
Press SET to conrm.
Press SELECT to conrm.
Using or buttons set a parameter value.
Follow steps 2-5, to set next parameters.
To exit the installer mode, wait 10 seconds
- thermostat will return automatically
to the main screen.
Press any key to deactivate sleep mode. Thermostat will return to the previous mode.
Thermostat is in sleep mode.
After new setpoint temperature set,
thermostat will return to the main screen.
After new setpoint temperature set,
thermostat will return to the main screen.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set
during the schedule - it will be maintained until next time interval starts according to programmed
schedule.
In this mode thermostat does not work according to the programmed schedule but it will maintain
selected temperature.
In this mode the“frost protection”temperature is maintained for a specic number of days.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature
for a specied number of hours (up to 9 hours). Once that time is over, thermostat returns to previous
mode.
Turning o hourly temperature override mode before time’s up
Turning O the Frost Protection mode
Begin the pairing process
End the pairing process
Test the pairing process
Temporary Override mode will be disabled when new schedule will be set.
To turn o the Manual Mode press button. Once the manual mode is o, the hand icon on
the thermostat will disappear.
To turn o the Holiday Mode, hold down button for 3 seconds.The airplane icon should
disappear from the display.
Temperature of the Frost Protection mode is set as default at 5°C.This temperature can be changed
in Installer Mode in d03 parameter.
When you want to change the batteries
your device will use the internal memory to
backup your settings. You have 30 seconds
to change the batteries before losing your
settings.
When the sleep mode is activated, all thermostat functions are paused.
Press the RESET button once. You can use a paper
clip. Your thermostat will be reset and will start up
automatically.
Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again.
Your device will be restarted.
If you bought the RT510TX and RXRT510 seperately then pair as follows. Please make sure that
receiver switchers are set on AUTO and ON position. Connect your receiver to power supply - LED
indicator will ash red.
2
2
4
4
1
1
3
3
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
3 sec
3 sec 3 sec
3 sec
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
Note:If you areusing the RT510RFpack, thepairing betweenthe thermostat and the receiver is alreadydone.
dxx Function Parameter Default value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature oset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
d04 Programmer selection 5/2 or 24 hr (7d) 52d
RESET
SELECT SET
TEST/ PAIRING
SELECT
+ −
+ −
SET
TEST/ PAIRING
SELECT SET
PressTEST / PAIRING button to check the
connection with the receiver.
ON
AUTO
OFF
MANUAL
1 sec
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
3 sec
3 sec
Hold and buttons simultaneously
for 3 seconds to start the sleep mode.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
6
1
3
5
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
WED
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
SAT
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
(the pairing process takes up to 9 minutes)
Press and hold TEST/PAIRING button
for 3 seconds.
3 sec
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
TEST/ PAIRING
SELECT SET
Once devices are successfully paired, LED on
the receiver will go solid red. Press and hold
TEST / PAIRING button for 3 seconds to end
the pairing process.
3 sec 3
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
Press TEST / PAIRING button again to
return to the main screen.
ON
AUTO
OFF
MANUAL
1 sec
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
TEST/ PAIRING
SELECT SET
THU
THU

Other manuals for RT510RF

3

This manual suits for next models

4

Other Salus Thermostat manuals

Salus RT520RF User manual

Salus

Salus RT520RF User manual

Salus RT310i User manual

Salus

Salus RT310i User manual

Salus RT510 User manual

Salus

Salus RT510 User manual

Salus VS35W User manual

Salus

Salus VS35W User manual

Salus T105RF User manual

Salus

Salus T105RF User manual

Salus ERT20RF User manual

Salus

Salus ERT20RF User manual

Salus HTR24 User guide

Salus

Salus HTR24 User guide

Salus RT300RF User manual

Salus

Salus RT300RF User manual

Salus rt505tx User manual

Salus

Salus rt505tx User manual

Salus HTR230 User guide

Salus

Salus HTR230 User guide

Salus ST320RF User manual

Salus

Salus ST320RF User manual

Salus FT100 Owner's manual

Salus

Salus FT100 Owner's manual

Salus DIGITAL PROGRAMMABLE THERMOSTAT User manual

Salus

Salus DIGITAL PROGRAMMABLE THERMOSTAT User manual

Salus Quantum SQ610 User manual

Salus

Salus Quantum SQ610 User manual

Salus RT510LG5V User manual

Salus

Salus RT510LG5V User manual

Salus WBRT520TX User manual

Salus

Salus WBRT520TX User manual

Salus RT200 User manual

Salus

Salus RT200 User manual

Salus ST620 User manual

Salus

Salus ST620 User manual

Salus RT510BC User manual

Salus

Salus RT510BC User manual

Salus VS20WRF User manual

Salus

Salus VS20WRF User manual

Salus ERT50 UP User manual

Salus

Salus ERT50 UP User manual

Salus Quantum WQ610 User manual

Salus

Salus Quantum WQ610 User manual

Salus iT500 User manual

Salus

Salus iT500 User manual

Salus RT510RF Service manual

Salus

Salus RT510RF Service manual

Popular Thermostat manuals by other brands

PW maintenance DT operating instructions

PW maintenance

PW maintenance DT operating instructions

Seitron TBM01M manual

Seitron

Seitron TBM01M manual

Vive TP-N-801 operating manual

Vive

Vive TP-N-801 operating manual

livin flame 5962200 manual

livin flame

livin flame 5962200 manual

Verdant VX Series installation manual

Verdant

Verdant VX Series installation manual

Thermosense STP322 instruction manual

Thermosense

Thermosense STP322 instruction manual

Energymizer T32 instructions

Energymizer

Energymizer T32 instructions

Heat Controller 7602-443 user manual

Heat Controller

Heat Controller 7602-443 user manual

Pro1 Technologies T721i Product installation guide

Pro1 Technologies

Pro1 Technologies T721i Product installation guide

Swegon Conductor W4 Instructions for use

Swegon

Swegon Conductor W4 Instructions for use

PSG HS-4024U Installation and operating instructions

PSG

PSG HS-4024U Installation and operating instructions

Strom SSRTPR05 user guide

Strom

Strom SSRTPR05 user guide

Honeywell Q539A installation instructions

Honeywell

Honeywell Q539A installation instructions

Siemens ET 141 Technical instructions

Siemens

Siemens ET 141 Technical instructions

AKO AKO-D1461 Series installation instructions

AKO

AKO AKO-D1461 Series installation instructions

Aube Technologies TH141-HC-28 user guide

Aube Technologies

Aube Technologies TH141-HC-28 user guide

Danfossss TP9000 Installation instructions user instructions

Danfossss

Danfossss TP9000 Installation instructions user instructions

REMKO ATR-4 operating instructions

REMKO

REMKO ATR-4 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.