Sams DVM-88 User manual

8x8
Routing switchers 8x8
- HDV-88
- DVM-88
- DAM-88
- SVM-88
- SAM-88a2
Copyright © 1999 - 2014 Sams elektronik d.o.o.
Published: 09. october 2012.
Updated: 27. november 2014.
Z10-3 edition 1
Code: 003.160
003.101
003.110
003.120
003.131
ENGLISH
Sams elektronik d.o.o.
48 Zivka Davidovica st.
11050 Belgrade
Serbia
Tel/Fax: +381 11 3806 253
+381 11 2402 212
www.sams.rs
Read the instructions before using the device.
Keep this manual for periodic usage.
USER MANUAL FOR USE AND MAINTENANCE

8x8
elektronik
Dear User,
Thank you very much for purchasing our product.
Your purchase is a wise investment. The equipment you have purchased is manufactured with great care from
high-quality parts and materials. It is designed to fully meet the needs according to specications, if properly
installed, used and maintained according to the enclosed instructions.
Any technical failure or deciency that occurs during the warranty period specied on the invoice of the
purchased equipment will be inspected and serviced by Sams elektronik doo or an authorized service center of
the manufacturer, with the conditions set out in the warranty statement.
THIS DEVICE IS INTENDED FOR PROFESSIONAL USE.
WARRANTY STATEMENT
1. Product has declared characteristics. Within the warranty period, manufacturer ensures the removal of
technical failures, product defects or replacement of products if declared characteristics of the product are
changed.
2. If the goods are not delivered as specied with the contract, the consumer has the right to request from the
manufacturer / service provider to eliminate the lack of conformity, without charge, repair or replacement,
or to request an appropriate price reduction or terminate the contract.
3. Any repair or replacement must be made within a reasonable time without signicant inconvenience to
the consumer, taking into account the nature and the purpose for which the consumer has purchased the
product.
4. The consumer has the right to terminate the contract, if he can realize the right to repair or replacement,
or if the manufacturer / servicer has not completed repair or replacement within a reasonable time or if
the manufacturer / servicer did not perform repair or replacement without signicant inconvenience to the
consumer.
5. The consumer may not terminate the contract if the lack of conformity of the product is negligible.
6. The product will function properly when used in accordance with the user manual.
7. Period of servicing the product is 6 years from the launch on the market.
The product purchased outside the territory of Serbia does not fall under the terms of this warranty, only to 1
year factory warranty from date of purchase.
TERMS OF WARRANTY
1. The warranty period begins on the date of sale referred in the invoice.
2. The buyer loses the right to warranty if the defect cause failure from not following the user manual
instructions, improper installation, comes to mechanical damage during use, repairs and modications by
unauthorized persons, installation of non-genuine spare parts, and if the buyer does not comply with all
warnings listed in the user manual.
3. The warranty is voided if the device is damaged during the disturbances from the environment, natural
disasters (oods, hail, etc.), suffered an electric shock or lightning strike.
IMPORTANT NOTES
1. Be sure to thoroughly read the user manual.
If you have any doubts about the instructions, contact the technical support of the manufacturer.
2. Before contacting for technical help, please make sure that are provided with all necessary conditions for
normal operation.
3. If the malfunction or defect in the device does not eliminate within a reasonable time from the date of
failure, the warranty period shall be extended for as many days as the unit is in service.
4. For all maintenance interventions shall solely be authorized services listed in this Warranty Certicate.
WARRANTY

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
3
Routing switchers
IMPORTANT SAFEY
WARNING
TO AVOID RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THE UNIT TO MOISTURE OR RAIN
The symbol “lightning in a triangle” is to alert the user to the presence of
high voltage. In poor conditions the user may be exposed to shock.
The symbol “exclamation mark in a triangle” is to alert the user to comply by
the terms of use in user’s manual, which is supplied with the device.
SAFETY WARNINGS
ELECTRICAL SHOCK HAZARD
DO N OT O PEN
CAUTION
RIZIK OD S TRUJNOG UDARA
NE O TVARATI
DOK JE P OD N APONOM
UPOZORENJE
CLASS I DEVICE
Grounding is connected to the chassis of the device.
The power supply is protected with fuse against overload.

8x8
elektronik
TECHNICAL SUPPORT AND SERVICE
Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In
the event that problems that occur can not be resolved, or if you have any questions regarding this
equipment or information about other products produced from Sams elektronik, contact your local sales
representative or call Sams elektronik directly through one of the ways listed below:
Sales: +381 11 3806 254
Technical support: +381 11 2402 212
Service: +381 11 4056 051
Email:
Web site: www.sams.rs
Address:
SAMS ELEKTRONIK d.o.o.
48 Zivka Davidovica st
11050 Belgrade
Serbia
WARNING
TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.
DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1. Read all safety and operating instructions before using the device.
2. Keep all safety and operating instructions.
3. Follow the instructions from the user manual.
4. Do not upgrade device, except in the case advised by the manufacturer.
5. Do not use the device in the presence of water and / or moisture.
6. Do not pour water or moisten the device with any type of liquid.
7. Openings on device are provided for ventilation.
8. Do not block air ow through the ventilation openings.
9. This product is powered by AC ~ 230V ± 10%, 50Hz.
10. This product is equipped with a three-wire cord with grounding.
11. This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.
12. Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.
13. Do not bend the power cord so that it can be damaged.
14. Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted
for the inputs and outputs of the device can cause severe damage and warranty void.
15. Do not use the device in an environment that contains ammable or explosive materials in any
physical state.
16. Turn off the power corde before cleaning. Do not use liquid, aerosol or ammable cleaners. Use
only a dry cloth.
17. Servicing is performed by a qualied person. Removing the cover user is exposed to high
voltages.
18. Never use the device when the cover is open and the device is powered on.
19. Do not expose to extreme high or low temperatures.
20. Do not expose to sudden temperature changes.
21. Call service in the following cases:
- The power cord or plug is damaged
- Liquid or foreign objects is inside the device
- The machine is exposed to water and moisture
- The device does not function according to specication
- The unit has been dropped or damaged
- The characteristics are signicantly changed
22. Use only specied replacement parts.
23. Professional person authorized by the manufacturer must check the device after completion of
service.
24. Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the
device.
Pictures and drawings listed in this user manual are for information purposes only and may differ
from the actual device. Design and specications of the device may change without prior notice.

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
5
Routing switchers
UNPACKING AND INSTALLATION....................................................................................6
MAINTENANCE..............................................................................................................6
REMOVAL AND STORAGE...............................................................................................6
DESCRIPTION...............................................................................................................7
INSTALLATION..............................................................................................................12
CP-88, MASTER REMOTE CONTROL 8x8 .........................................................................14
CP-8, SLAVE REMOTE CONTROL 8X1..............................................................................15
CONNECTORS...............................................................................................................16
CONFIGURATION AND CONNECTION, GRAPHIC EXAMPLE ...............................................16
SOFTWARE...................................................................................................................17
NOTES .........................................................................................................................18
PageDescription
TABLE OF CONTENTS

8x8
elektronik
UNPACKING AND INSTALLATION
REMOVAL AND STORAGE
MAINTENANCE
The box contains:
- Device
- Power corde
- Master / Slave remote control (optional)
- Power supply (optional)
- User manual (optional)
Before use, check the contents of the box. For any deciency report to the seller or the manufacturer
of the product.
DEVICE IS INSULATED BY PROTECTIVE WRAP AND PACKED IN A CARDBOARD BOX.
DEVICE IS SENSITIVE TO SHAKES AND DROPS. HANDLE WITH CARE DURING TRANSPORT
AND ASSEMBLY.
Check if the product is damaged during transport.
1. Before dismantling the device, switch off the power, remove
the power cord and remove all other connectors.
2. Remove the four screws for fastening.
3. Remove the device from rack cabinet.
4. Wrap the machine in the foil to protect it from dust. Package
it in a box.
5. The device must be stored in a room without moisture.
The system maintains only person authorized by Sams elektronik
doo.
Any voluntarily opening device, upgrading or servicing is strictly
prohibited and is subject to warranty void, and the possibility of
injury.
Places for fastening
PROCEDURES FOR SAFE USE OF THE DEVICE:
1. - Remove the protective wrap from the chassis.
- For devices that are AC 230V / 50Hz powered, the device is supplied with power cord.
- Use only power corde that comes with the device.
2. Device is mounted in a 19“ special-purpose rack cabinets designed for this type of device. Screw
device with four screws. Screws for fastening are not supplied with the device.
3. The device must be connected to ground. A device that is not connected to the grounding does
not function properly according to factory declarations and can cause adverse effects on users and
other equipment.
4. Strictly comply to all steps for proper connection of devices in the system.
Illustration - mounted device

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
7
Routing switchers
DESCRIPTION
III
6
HD/SD SDI ROUTING SWITCHERS
• Sams elektronik d.o.o. • 48 Zivka Davidovica st. • 11050 Belgrade • Serbia •
HDV-88 is a compact 8x8 HD / SD SDI matrix with two outputs per destination, which allows up to 1.5Gb/sec. HDV
series is based on the latest technology that supports HD. Device has LED detection of type of reference signal. It
also has automatic rekloking and equalization offset length up to 100m of 1694A cable. Uses the standard CP-88
Remote Control, but can also be controlled from web browser over TCP/IP. The device can be combined with analog
or digital audio matrix 8x8.
TECHNICAL SPECIFICATIONS
GENERAL INFORMATION
- Code: ....................................................................003.160
- Weight: ................................................................... 1.5 Kg
- Type: .........................................................1RU rack frame
- Dimensions: ........................................ 1RU x 19” x 100mm
- Required: ....remote control CP-88, cable for connection with
remote control
- Delivery includes: ............. device, power corde, user manual
INPUT
- Number: ..........................................................................8
- Signal type: ....................................HD/SDI to SMPTE 292M
- EQ: .............................Automatic to 100m with 1694A cable
- Impedance: .................................................................75Ω
- Connectors: ................................................................ BNC
Specications and designs are subject to change without notice
HDV-88
HD/SD SDI routing switcher 8x8
- 2 outputs per destination
- Switching HD / SD signals
- Auto equalization and reclocking
- Vertical interval switching per SMPTE RP 168-1993
- Can function independently or be linked with other
8x8 routing switchers
- Power down memory recovery
- Automatic recognition of reference standard signal
- PC control
ORDERING INFORMATION
Code Name Description
003.160 HDV-88 HD/SD SDI routing switcher 8x8
003.901 CP-88 Remote control 8x8
front side
rear side
OUTPUT
- Number: ..................................................................8, dual
- Connectors: ................................................................ BNC
- Impedance: .................................................................75Ω
- Output level: ............................................... 800mV ± 10%
- Jitter: .................................................... < 0.2UI at 100KHz
REFERENCE INPUT
- Number: ...................1, BNC (Three level sync / Black Burst)
POWER
- Voltage: ................................................. ~230V AC ± 10%
- Power: .......................................................................30W
- Frequency: ................................................................ 50Hz
- Overload protection: .............. front Mounted Circuit Breaker
TEMPERATURE
- Performance: .......................................................... 5-40°C
- Operating: .............................................................. 0-50°C

8x8
elektronik
III
11
SDI ROUTING SWITCHERS
• Sams elektronik d.o.o. • 48 Zivka Davidovica st. • 11050 Belgrade • Serbia •
The DVM-88 video routing switcher is a compact 8x8 serial video module. Input conform to all component and
composite digital standards signals. The Auto reclocking circuitry is standards independent. Auto equalization circuitry
compensates fo up to 200 m of 1694A cable.
TECHNICAL SPECIFICATIONS
GENERAL INFORMATION
- Code: ....................................................................003.101
- Weight: ................................................................... 2.5 Kg
- Type: .........................................................1RU rack frame
- Dimensions: ........................................ 1RU x 19” x 250mm
- Required: ....remote control CP-88, cable for connection with
remote control
- Delivery includes: ............. device, power corde, user manual
INPUT
- Number: ..........................................................................8
- Signal type: ........................... 540, 360, 270, 177, 143 Mb/s
- EQ: .......................................................Automatic to 200m
- Impedance: .................................................................75Ω
- Connectors: ................................................................ BNC
Specications and designs are subject to change without notice
DVM-88
SDI routing switcher 8x8
- Switching digital video signals
- 8x8 SDI routing switcher
- Auto equalization and reclocking
- 540, 360, 270, 177, 143 Ms/s data
- Vertical interval switching per SMPTE RP 168-1993
- Can function independently or be linked with other
8x8 routing switchers
- Power down memory recovery
- PC control
ORDERING INFORMATION
Code Name Description
003.101 DVM-88 SDI routing switcher 8x8
003.901 CP-88 Remote control 8x8
front side
rear side
OUTPUT
- Number: ..........................................................................8
- Connectors: ................................................................ BNC
- Impedance: .................................................................75Ω
- Output level: ............................................... 800mV ± 10%
REFERENCE INPUT
- Number: ..............................................1, BNC (Black Burst)
POWER
- Voltage: ................................................. ~230V AC ± 10%
- Power: .......................................................................30W
- Frequency: ................................................................ 50Hz
- Overload protection: .............. front Mounted Circuit Breaker
TEMPERATURE
- Performance: .......................................................... 5-40°C
- Operating: .............................................................. 0-50°C

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
9
Routing switchers
III
14
AES/EBU ROUTING SWITCHERS
• Sams elektronik d.o.o. • 48 Zivka Davidovica st. • 11050 Belgrade • Serbia •
The DAM-88 is an 8x8 digital audio routing switcher with balanced/unbalanced input and outputs, jumper selectable.
This top of the line routing switcher provides high performance circuits and can be congured in many ways as will
as combined with other matrix tips such as analog video and serial digital video.
TECHNICAL SPECIFICATIONS
GENERAL INFORMATION
- Code: ....................................................................003.110
- Weight: ................................................................... 2.5 Kg
- Type: .........................................................1RU rack frame
- Dimensions: ........................................ 1RU x 19” x 250mm
- Required: ....remote control CP-88, cable for connection with
remote control
- Delivery includes: ............. device, power corde, user manual
INPUT
- Number: ..........................................................................8
- Impedance: ...................... 110Ω balanced / 75Ω unbalanced
- Connectors: ..... 25-pin SUB D female or 3-pin terminal strip /
BNC
OUTPUT
- Number: ...................................................................8 or 4
- Connectors: .25-pin SUB D male or 3-pin terminal strip / BNC
- Impedance: ...................... 110Ω balanced / 75Ω unbalanced
- Signal level: ....................................................... 0.2-7V p-p
PERFORMANCE
- Sampling rates:....................................................32-96KHz
Specications and designs are subject to change without notice
DAM-88
AES/EBU routing switcher 8x8
- Switching of digital audio signals
- 8x8 AES/EBU (110Ω/75Ω) routing switcher
- 110Ω / 75Ω balanced or unbalanced input and
outputs
- Samplerate 32-96KHz
- Word clock 48KHz reference (optional)
- Separate use or it can be combined with other 8x8
matrix
- Power down memory recovery
- PC control
ORDERING INFORMATION
Code Name Description
003.110 DAM-88 AES/EBU routing switcher 8x8
003.901 CP-88 Remote control 8x8
front side
rear side
POWER
- Voltage: ................................................. ~230V AC ± 10%
- Power: .......................................................................30W
- Frequency: ................................................................ 50Hz
- Overload protection: .............. front Mounted Circuit Breaker
TEMPERATURE
- Performance: .......................................................... 5-40°C
- Operating: .............................................................. 0-50°C

8x8
elektronik
III
21
ANALOG VIDEO ROUTING SWITCHERS
• Sams elektronik d.o.o. • 48 Zivka Davidovica st. • 11050 Belgrade • Serbia •
The SVM-88 is a 8x8 video routing switcher with vertical interval switching. High performance circuits in SMD
technology assure undiminished signal quality. The SVM-88 is well suited for all demanding routing tasks in studio or
broadcast applications. The built-in RS-232 interface allows the user to control the router via RS-88 PC-Software. The
control bus technology allows the linking of the unit with the SAM-88 to create an audio-follow-video router.
TECHNICAL SPECIFICATIONS
GENERAL INFORMATION
- Code: ....................................................................003.120
- Weight: ................................................................... 2.5 Kg
- Type: .........................................................1RU rack frame
- Dimensions: ........................................ 1RU x 19” x 100mm
- Required: ....remote control CP-88, cable for connection with
remote control
- Delivery includes: ............. device, power corde, user manual
INPUT
- Number: ..........................................................................8
- Level: .................................................1V p-p nominal video
- Impedance: .................................................................75Ω
- Connectors: ................................................................ BNC
OUTPUT
- Number: ..........................................................................8
- Connectors: ................................................................ BNC
- Impedance: .................................................................75Ω
- Isolation: ................................................ > 43dB at 5.5MHz
- Hum on output: .......................................................< 1mV
- Nominal output level: ...............................................1V p-p
PERFORMANCE
- Gain: .............................................................-3dB to +3dB
- Gain stability: .................................................... < ± 0.1dB
- Frequency response: ................... ± 0.1dB (50Hz to 5.5MHz)
Specications and designs are subject to change without notice
SVM-88
Analog video routing switcher 8x8
- High quality
- 8x8 analog video routing switcher
- 200 MHz bandwidth
- Vertical interval switching
- Can function independently or be linked with other
8x8 routing switchers
- Power down memory recovery
- PC control
ORDERING INFORMATION
Code Name Description
003.120 SVM-88 Analog video routing switcher 8x8
003.901 CP-88 Remote control 8x8
front side
rear side
POWER
- Voltage: ................................................. ~230V AC ± 10%
- Power: .......................................................................30W
- Frequency: ................................................................ 50Hz
- Overload protection: .............. front Mounted Circuit Breaker
TEMPERATURE
- Performance: .......................................................... 5-40°C
- Operating: .............................................................. 0-50°C

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
11
Routing switchers
III
30
ANALOG AUDIO ROUTING SWITCHERS
• Sams elektronik d.o.o. • 48 Zivka Davidovica st. • 11050 Belgrade • Serbia •
The SAM-88a2 is a 2ch 8x8 audio routing switcher. High performance circuits in SMD technology assure undiminished
signal quality. The SAM-88 is well suited for all demanding routing tasks in studio or broadcast applications. The built-
in RS-232 interface allows the user to control the router via RS-88 PC-Software. The control bus technology allows
the linking of the unit with the SVM-88 to create an audio-follow-video router.
TECHNICAL SPECIFICATIONS
GENERAL INFORMATION
- Code: ....................................................................003.131
- Weight: ................................................................... 2.5 Kg
- Type: .........................................................1RU rack frame
- Dimensions: ........................................ 1RU x 19” x 250mm
- Required: ....remote control CP-88, cable for connection with
remote control
- Delivery includes: ............. device, power corde, user manual
INPUT
- Number: ..........................................................................8
- Impedance: ............................................ > 40KΩ, balanced
- Connectors: ........................................ 25-pin SUB D female
- Common mode rejection: ............................> 40dB at 50Hz
OUTPUT
- Number: ..........................................................................8
- Connectors: ........................................... 25-pin SUB D male
- Impedance: .................................................................10Ω
- Output to output isolation: ............ > 70dB at 20Hz to 20KHz
- Maximum output level: .............................................+24dB
Specications and designs are subject to change without notice
SAM-88a2
2ch analog audio routing switcher 8x8
- High quality
- 8x8 2ch analog audio routing switcher
- Balanced signals
- Can function independently or be linked with other
8x8 routing switchers
- Power down memory recovery
- PC control
ORDERING INFORMATION
Code Name Description
003.131 SAM-88a2 2ch audio routing switcher 8x8
003.901 CP-88 Remote control 8x8
front side
rear side
PERFORMANCE
- Gain: .............................................................-6dB to +6dB
- Frequency response: ................. < ± 0.1dB (20Hz to 20KHz)
- S/N ratio: ....................... > 100dB unity gain 20Hz to 20KHz
- TDH: ........................................... 0.01 % @ 20Hz to 20KHz
- Inter channer cross talk:............... > 90dB @ 20Hz to 20KHz
POWER
- Voltage: ................................................. ~230V AC ± 10%
- Power: .......................................................................30W
- Frequency: ................................................................ 50Hz
- Overload protection: .............. front Mounted Circuit Breaker
TEMPERATURE
- Performance: .......................................................... 5-40°C
- Operating: .............................................................. 0-50°C

8x8
elektronik
FUSE: 500mA
AC ~230V/50Hz
www.sams.rs
Made in Serbia
HDV-88
SN:
HD / SD INPUTEXT. REF.
REMOTE
HD / SD OUTPUT
1
2
3
4
5
6
7
8
24 6 8
1 3 5 7
USE ONLY WITH A250V FUSE
1
2
eksterna
referenca
FUSE: 500mA
AC ~230V/50Hz
POWER
VIDEO INPUTEXT. REF. VIDEO OUTPUT
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
REMOTEINPUT OUTPUT
USE ONLY WITH A250V FUSE
3
FUSE: 500mA
AC ~230V/50Hz
POWER
AUDIO INPUT AUDIO OUTPUT
1-8 CH 1 1-8 CH 2 1-8 CH 1 1-8 CH 2
REMOTEINPUT OUTPUT
USE ONLY WITH A250V FUSE
FUSE: 500mA
AC ~230V/50Hz
POWER
REMOTEINPUT OUTPUT VIDEO INPUT
1
REF
3
2 4
5 7
6 8
VIDEO OUTPUT
1 3
2 4
5 7
6 8 www.sams.rs
Made in Serbia
SVM-88
CODE: 003.120
SN:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
USE ONLY WITH A 250V FUSE
Connect the power cord.
The device works only on AC ~ 230 V / 50 Hz.
video outputs
video outputs
video outputs
audio outputs CH1/CH2
connection
with
remote
control
connection
with
remote
control
connection
with
remote
control
connection
with
remote
control
external
reference
video inputs
video inputs
video inputs
audio inputs CH1/CH2
Connect all necessary connectors
before the unit is turned on.
HDV-88, rear side
DVM-88, rear side
SVM-88, rear side
SAM-88a2, rear side
Turn on the device by pressing
power switch.
external
reference (1st input)
For best signal quality, use:
- Belden 1694A coaxial cable for SDI
- Belden 8281 or better coaxial cable for analog video
INSTALLATION

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
13
Routing switchers
HD/SD SDI routing switcher 8x8 HDV-88
www.sams.rs
1080i 1080p720pPALNTSC
REMOTE
EXT. REF. SD HD
4
REMOTE - RED - remote is ON / FLASH - remote is OFF
NTSC, PAL - YELLOW - reference is ON / FLASH - reference is OFF
720p, 1080i, 1080p - GREEN - reference is ON / flash - reference is OFF
REF WDT +5V
REF
WDT
-V +V WDT
HDV-88
DVM-88
SVM-88
SAM-88 (a1 i a2)
SDI routing switcher 8x8 DVM-88
www.sams.rs
REF WDT +5V
SVM-88
www.sams.rs
REF
WDT
CVBS routing switcher 8x8
2ch balanced analog audio routing switcher 8x8 SAM-88a2
www.sams.rs
-V +V WDT
1080i 1080p720pPALNTSC
REMOTE
EXT. REF. SD HD
Status is represented by LEDs on the front side
HDV-88, front side
DVM-88, front side
SVM-88, front side
SAM-88a2, front side
REF - YELLOW - reference is ON / YELLOW FLASH - reference is OFF
WDT - RED - remote is ON / RED FLASH - remote is OFF
+5V - RED - power indication
REF - YELLOW - reference is ON / YELLOW FLASH - reference is OFF
WDT - RED - remote is ON / RED FLASH - remote is OFF
-V - SVETLI ZELENO - power indication
+V - SVETLI CRVENO - power indication
WDT - SVETLI CRVENO - remote is ON / RED FLASH - remote is OFF

8x8
elektronik
FUSE: 500mA
AC~230V/50Hz
POWER
www.sams.rs
Made in Serbia
CP-88
CODE: 003.901
SN:
RISK OF ELECTRIC SHOCK
DO NOTOPEN
CAUTION
ROUTERRS-232
4321
SLAVE REMOTE CONTROL
USE ONLY WITH A 250V FUSE
CONNECTION TO SLAVE REMOTE CONTROLS
CONNECTION
TO PC
CONNECTION
TO ROUTING
SWITCHER POWER
SWITCH
POWER
SOCKET
UNDO LOCK PANEL
LOCK
INPUTS OUTPUTS VIDEO AUDIO 2
AUDIO 1
Remote control panel 8x8
CP-88
www.sams.rs
SOURCE
SOURCE
DESTINATION
DESTINATION
PC
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
VIDEO AUDIO 1 AUDIO 2
UNDO LOCK PAN. LOCK
INPUTS - source keys
OUTPUTS - destination keys
VIDEO - control of video router
AUDIO 1 - control of audio 1 router
AUDIO 2 - control of audio 2 router
UNDO - one step back
LOCK - destination lock
PANEL LOCK - remote control lock
SLAVE REMOTE CONTROLS - to connect slave
remote controls
PC - connection to PC
ROUTER - connection to routing switcher
CP-88 is master remote control for video, audio and data routing switchers 88.
There are two types of remote controls:
1. X-Y command where “X” is source, a “Y” is destination;
2. X-1 command where “X” is source, a “1” is destination (in this case there is only one destination).
CONNECTIONS TO X-Y COMMAND
On the front panel there are buttons to select the type of signal (audio, video, data). The command
connects in three levels, therefore press if necessary VIDEO-AUDIO1-AUDIO2 (DATA) ENABLE button.
If the button is illuminated, you can use this audio, video, or data source. When the VIDEO and AUDIO
ENABLE buttons are included, routing switcher operate in either an audio-follow-video. To link the
source and destination, rst press and hold the desired destination, and then press the desired source.
Connection can be made also vice versa.
If you notice that the LOCK button is illuminated when you press a destination, that destination is locked
for use. To connect a source to a destination you have to unlock it rst.
The keys are numerically dened. It can connect one source to multiple destinations (except in the
case of the DATA matrix, which connects one source to a single destination. To check that the source is
connected to that destination, simply press the desired source and destination buttons will illuminate. If
the destination is not illuminated, that source is not used. In the same way, you can press a destination
and check to which the source is connected. Before checking ensure it is turned on the appropriate
video, audio or data signal level. In a system where are slave controls, the master command has control
over all destinations and can connect and those destinations that are assigned to slave commands.
LOCK
Use this option when you want to lock destination. To lock the destination, press and hold the desired
destination it then press LOCK. In the same way, it unlocks the destination. From that moment that
destination button ashes, which indicates that it is locked. On that destination nothing else can be
brought as a source until destination is unlocked.
UNDO
Use this option if you want to restore the previous state of the connection. When you press a destination
and if UNDO button is illuminated, then it is possible to return to the previous state of the connection.
UNDO option saves only one step in all three levels (Video-Audio1-Audio2) and each level can be
called independent. UNDO option may not be called if the routing switcher powered on for the rst
time. Remote control saves the previous state connections in the event of a power failure or deliberate
shutdown. In a system where two or more commands can control the same destination, return to the
previous state can be made with any such command.
PANEL LOCK
Use this option when you want to lock the entire panel. In this case, the control of the routing switcher
takes the PC. When PANEL LOCK is off, the software on the PC is used only for monitoring and PC
ENABLE LED ashes.
PC ENABLE
LED ashes when the PC software is active. Control from the PC is used to connect XY and has the same
functions as the master command.
CP-88, MASTER REMOTE CONTROL 8x8

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
15
Routing switchers
REMOTE
www.sams.rs
Made in Serbia
SN:
ADDRESS:
SLAVE REMOTE FOR:
32x32
NO USER - SERVICEABLE PARTS INSIDE!
REFER SERVICING TO QUALIFIED PERSONNEL!
16x16
64x64
OTHER
UNDO LOCK PANEL
LOCK
INPUTS
REMOTE
VIDEO AUDIO 2
AUDIO 1
Remote control panel 8x1
CP-8
www.sams.rs
SOURCE
SOURCE
PC
1 3 5 7
2 4 6 8
VIDEO AUDIO 1 AUDIO 2
UNDO LOCK PAN. LOCK
CP-8 is slave remote control for routing switchers 8x8.
Connect slave command to master. Press and hold button PANEL LOCK for a few seconds. While hold
PANEL LOCK select the desired destination by pressing the source (SOURCE). Make sure that the
selected destinations do not match with already selected on the master or another previously set slave
commands. Pressed keys will start blinking. In this way, you will notice that the selected destinations will
be used only to this command. Select one destination. After selecting release PANEL LOCK key.
LOCK
Use this option when you want to lock destination. To lock the destination, press and hold the desired
destination it then press LOCK. In the same way, it unlocks the destination. From that moment that
destination button ashes, which indicates that it is locked. On that destination nothing else can be
brought as a source until destination is unlocked.
UNDO
Use this option if you want to restore the previous state of the connection. Since this type of commands
uses only one destination if UNDO button is illuminated, then it is possible to return to the previous
state of the connection. UNDO option saves only one step in all three levels (Video-Audio1-Audio2) and
each level can be called independent. UNDO option may not be called if the routing switcher powered
on for the rst time. Remote control saves the previous state connections in the event of a power failure
or deliberate shutdown. In a system where two or more commands can control the same destination,
return to the previous state can be made with any such command.
PANEL LOCK
Use this option when you want to lock the entire panel. In this case, the control of the routing switcher
takes the PC. When PANEL LOCK is off, the software on the PC is used only for monitoring and PC
ENABLE LED ashes.
PC ENABLE
LED ashes when the PC software is active.
INPUTS - source keys
OUTPUTS - destination keys
VIDEO - control of video router
AUDIO 1 - control of audio 1 router
AUDIO 2 - control of audio 2 router
UNDO - one step back
LOCK - destination lock
PANEL LOCK - remote control lock
REMOTE - connection to master remote control
CP-8, SLAVE REMOTE CONTROL 8X1

8x8
elektronik
INPUT (Female connector on back panel) OUTPUT (male connector on back panel)
G G G G NC
GGGG
1
25
1 3 5 7
2 4 6 8
GGGG
NC
G G G G
1
25
1357
2468
13
14
13
14
Connector for Control Panel
(male/female) SUB D9 pin
Connector for PC (male/female) SUB D9 pin
1 1
55
99
66
G G
V+ V+
TX TX
RX RX
female male
1 1
55
99
66
GND
female male
PC TX
PC RX
2 3 4
78
2
3
4
7
8
2
3
4
7
8
2 3 4
78
PC
CONNECTORS
CONFIGURATION AND CONNECTION, GRAPHIC EXAMPLE
Slave remote
controls
Master remote
control
Audio and video
routing switchers

8x8 Sams elektronik d.o.o. • [email protected] • www.sams.rs
elektronik
17
Routing switchers
This program controls the routing switcher.
Designed as a replacement of the main commands.
The program is used only in Windows OS. It is recommended to be used on newer types of
computers.
To view the entire program window minimum screen resolution must be 1024x768px.
Also, the computer must have a free serial port (RS-232) to communicate with the routing switcher.
Installation is simple. Insert the installation CD into the CD-ROM. If the installation itself does not start,
open the contents of the disc and double-click setup.exe.
Start the program (Figure 1). Press the “Properties” button (Figure 2) to set the communication
parameters. It is very important to choose the correct serial port to COM selection. If the correct port is
selected and if routing switcher is connected to a PC, the “COM OK” green colors will appear. It will not
be included if you do not connect properly or if routing switcher is turned off.
SOFTWARE
# 1 # 2
Loading status Saving status
Panel is LOCKED Naming inputs / outputs. Double click on eld

8x8
elektronik
Sams elektronik d.o.o. • [email protected] • www.sams.rs
18
Routing switchers
NOTES
If you want to control the routing switcher using a PC, press PANEL LOCK on the front panel of the
remote control. Red indicator “PC ENABLE” will appear instead of “OK COM”. Destinations that were
previously locked will not be used.
Using the program is simple. Place the arrow at the intersection (XY) and press the left mouse button.
The parameters for this intersection will appear with the selection VIDEO-AUDIO 1-AUDIO 2. When you
choose press the OK button. The connection is established and it can be seen on the screen. If you want
to save your connections status press the SAVE button. If you want to load some of the saved status of
the connections, press LOAD button.
You can lock the PC panel by pressing the LOCK button on the menu. Unlocking is done closing window
UNLOCK on the center of the screen. If you want to lock certain destinations press button KEY. In the
same way it unlocks. By pressing UNDO return to the previous state of the selected intersection.
This manual suits for next models
4
Table of contents
Other Sams Switch manuals
Popular Switch manuals by other brands

Alpha Power
Alpha Power TST200 series user manual

Philips
Philips SWV2052W/10 instruction sheet

NTI
NTI RACKMUX-V15-N-PRIMUX Installation and operation manual

MikroTik
MikroTik RB2011iL-IN manual

Phoenix Contact
Phoenix Contact 1001T-4POE Installation notes for electricians

MobileView
MobileView 3200 quick reference