Sangamo Choice Rstat 7 Guide

INSTALLATION AND USER INSTRUCTIONS
DIGITAL, RF DELUXE PROGRAMMABLE ROOM THERMOSTAT
This programmable room thermostat has been designed to bring you comfort and energy economy.
It allows you to program and regulate your heating system at 3 temperature levels:
•Comfort
•Comfort2
•Economy
plus
•FrostProtection
It alsoenablesyoutoprogramandregulateair-conditioningat2temperaturelevels:
•Comfort
•Economy
AlargebacklitLCDonthethermostatprovidesclearfeedbackfortheuserandinresponsetoprogram
settings,transmitsRFsignalstothewallmountedreceiverinstallednexttotheboilerthatisbeing
controlled.
Eachdayisconvenientlysplitinto48timeperiodsforyoutoprogrammeaccordingtoyourlifestyle.
ok
–+
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 3 years from the Date of Manufacture. If it should become
defective, please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the Company operates a Customer Care Policy.
This means that we welcome your comments and complaints, as it can help us to improve our services to you,
our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to
change without prior notice.
Sangamo Limited, Industrial Estate, Port Glasgow, Renfrewshire PA14 5XG
Tel: 01475 745131 Fax: 01475 744567
143712_A
CHOICE RSTAT 7
Technical Helpline: 01475 745131
Features
• Wireless radio communication between thermostat
andreceiverbox
•24hr,5/2dayor7dayprogrammable
•3offpreset&nonadjustableprogrammes
•1offfreeuseradjustableprogramme
•Programmablein30minsteps
•3offtemperaturelevels,Comfort,Comfort2,
EconomyplusFrostProtection
•Batterypowered(withlow-powerindicator)
•AutomaticorManualModeselection
•StandbyModewithFrostProtection
•HolidayModewithFrostProtection
•Temporarytemperatureoverride
•Timedtemperatureoverride
•AutomaticSummer/Wintertimechange
•OptimisationandAnticipationfunctions
•Heating,AirConditioningorbothmodeoptions
•Largeclearbacklitdisplayshowingprogrammeproleforcurrentday
•Temperatureadjustmentrange5to30°C

Temporary Override–enablesyoutoadjustcurrenttemperaturesetpointuntilthenextprogramstep.During
theoverridethecurrentsetpointtemperatureashes
Timed Override-allowstimedmodicationoftheroomtemperatureatanytime.Thetimemaybesetfrom
15minutesto12hoursusingparameterPA:1
What to do if
The symbol is displayed : change the batteries.
Theheatingwillnotstart:thereceiverisoutofrangeofthethermostat(transmitter).Moveitcloser.
ThereceiverdoesnotrecognisetheThermostats(transmitters)code:recongurethereceiver
Theapplicationdoesnotstartordoesnotstop:thereceiverorThermostat(transmitter)isinanarea
disturbedbyradioemissions(radio,television,etc):movethereceiverorthermostat(transmitter)fromthe
disturbed area.
If problems persist, contact your electrician
211
Technical Characteristics
Transmitter
Powersupply: 2Alkalinebatteries1.5V(typeAAA)
Batterylifespan: 2years
Powerreserve: 10mins
Temperatureadjustmentrange: 5to30°C(alltemperaturelevels)
Temperaturedisplayrange: 0to40°C
Operatingtemperature: 0to45°C
Storagetemperature: -25to70°C
Clockaccuracy: <1sec/day
Protectionrating: IP30
Pollutionclass: 3
Dimensions(LxHxD): 97x138x30mm
Transmissionfrequency: 868.3Mhz
Receiver
Powersupply: 230Vac50Hz
Contactrating: 8(3)A,250Vac(Voltfreechangeovercontacts)
Radiofrequency: 868.3Mhz
Receivercategory: 2
Protectionrating: IP43
Insulation class: 11
Operatingtemperature: -10to60°C
Storagetemperature: -20to70°C
Flexiblewiresize: 0.5-1.5mm2
Rigidwiresize: 0.5-2.5mm2
Dimensions(LxHxD): 130x60x27mm
Typicalrange: >150muninterruptedand50minbuilding
Complieswith: EN60730-1,EN60730-2-1,EN60730-2-7,EN60730-2-9,
EN60730-2-11,EN60950-1,EN60950-1/A11,EN12098-2,
EN12098-5,EN301-489-3,EN300-220-1,EN300-220-2
andEN301-489-1
PressMENU,cursorunderPROG Day/DayGroupindicatorsash Adjustby+/-
PressOK Programnumberashes Adjustby+/-
PressOK NextDay/DayGroupindicatorsash,ifappropriateor
returnstoAutoMode
Adjustby+/-
PressOK Programnumberashes Adjustby+/-
PressOK RepeatprocedureforallremainingDaysifappropriate
Press+/-toadjustTempSet TempSetashing
PressMENUx7 Tocancel&returntoAutomode
Press TimeCountashing Adjustby+/-
PressOK TempSetashing Adjustby+/-
PressOK Timeperiodashesonprogrammeproleforday
PressMENU Tocancel&returntoAutomode
PressOK 1stperiodonProgrammeProleashing SelectTempSetpointforthisperiod
Press+/-,, Gotoperiodinprogrammetobechanged SelectTempSetpointforthisperiod
Press , or button Nextperiodonprogrammeproleashes Repeatprocedureforremainderof24hrprole
PressOK NextDay/DayGroupindicatorsashesif
necessaryorreturnstoAutoMode

Thewallmountedreceivershouldbeinstalledclosetotheboiler.IttakestheRFsignalsfromthethermostat
and switches the boiler accordingly.
Important : The thermostat and receiver are paired in the factory and are ready for use.
ok
–+
1)Keyformenuaccess
2)Keytoaccessholiday
3)Keytoaccessthetemporayoverride
4)ConrmationkeyOK
5)Adjustmentkeys+and -
6)Indicatorfordaysoftheweek
7)Automaticmode/manualmode(thermostatwithout
program)
8)Temperatureset-pointsadjustment
9)Standby
10)Heating/Air-conselector
11)Programming/programselection
12)Timeanddateadjustment
13)Adjustmentofsettings
14)Ambienttemperature
15)Heatingorairconditioningindicator
16)Currentmode(heatingorairconditioning)
17)Currentsetting( , , , )
18)Temperatureofcurrentsetting
19)Telephonic remote-control
20)Batteryuseindicator
21)Proleoftoday’sprogram
22)Currenttime
Adjusting the temperature set points
Heating(H)defaults:Comfort =19°C,Comfort2 =20°C,Eco =16°C
Air-con(C)defaults:Comfort =24°C,Eco =29°C
Programming
There are four program choices
P1,P2,P3arepre-recordedandcannotbemodied
P4isfreeforapersonalisedprogram
NoteP1oisonlyavailablewhentheoptimisationparameterisactive,settoAuto(PA:9)
P1isactivated7daysperweekbydefault.Ifthiststherhythmofyourlifethenremaininautomaticmode;
if not, continue
NoteP4Aisonlyactivewhentheanticipationparameterisactive,setto1hr,2hror3hr(PA:9)
30
min.
in
Eco
30
min.
in
Comfort
30
min.
in
Comfort
2
3
10
Thermostat Description
Receiver Description
A-Functionbutton,fct
B-Operatingindicatorlight.Thislightislitwhentheoutputcontactof
thereceiverisclosed=ON.
C-Codingindicator:THislightashesduringcodingoperations
D-Conguationbutton,cfg.
fct cfg
fct
LED
cfg
LED
PressMENU,cursorunder Comfort1Tempashing Adjustby+/-
PressOK Comfort2Tempashing Adjustby+/-
PressOK EcoTempashing Adjustby+/-
PressOK Return to Auto mode
P1=Comforttemperturefrom06:00to23:00.
Ecotemperaturefrom23:00to06:00.
P1o = Optimisation(onlywithP1).
Comforttemperturefrom07:00to23:00.
Ecotemperaturefrom23:00to07:00.
P2= Comforttemperturefrom06:00to08:30andfrom
16:30to23:00.
Ecotemperaturefrom08:30to16:30andfrom23:00
to06:00.
P3= Comforttemperturefrom06:00to08:30from11:30
to13:30andfrom16:30to23:00.
Ecotemperaturefrom08:30to11:30andfrom13:30to
16:30andfrom23:00to06:00.
P4= afreeprogramwhichallowsyoutocreateupto5
Comforttemperatureperiodsand5Ecotemperature
periods, for each of the days of the week.

Deleting a wireless link
ForFactoryresettingofthereceiver(deletionofallradiolinks);Givealongpress(>10secs)
onbutton(D)cfg.
Heating/Air Con reversibility
ThisfunctionallowsyourinstallationtoswitchfromHeatingtoAirConditioningmode.(PA5=HConly)
PressingA(fct)buttonwillmodifythecurrentmode
Toensureitscorrectoperationthethermostatshouldbesituatedapproximately1.3mabovetheooraway
from direct sunlight, heat sources and drafts.
The thermostat may be surface mounted to a wall using its surface mounted back plate or remain portable
using the table stand provided. Insert batteries into thermostat and then locate into
position .
ThisproductmustbeinstalledbyasuitablycompetentpersoninlinewiththelatestIEEregulations.
The receiver is normally located close to the boiler and a length of four core cable is provided for
connection.
Brown–Live
Blue–Neutral
Grey&Black–connectiontotheboiler
4 9
Technical Characteristics
Thermostat Installation
–+
ok
–+
ok
–+
ok
1 2
3 4
Receiver Installation
Selectparameter usingthemenukey(1)
GivealongpressonOK:PA:1displays
GiveashortpressonOKuntilCF9(cfg)displays
OFFblinks
Press+,ONiscontinuous
GiveashortpressonOK:CH1(=zone1)displays
Thereceiverswitchestoconguarationmode.LED(C)(cfg)iscontinuouslylitred
LED(B)(fct)blinksinred/green
Selectthereceivertounlink:giveashortpressonbutton(A)(fct)ofthereceiver
LED(B)(fct)blinksgoesout
CH1(=zone1)ONdisplayonthetransmitterforseveralseconds
Deletionofthelink:givealongpressonbutton(A)(fct)untilLED(C)(cfg)startsto
blink,thenreleasebutton(A)(fct).LED(B)(fct)goesout,LED(C)(cfg)iscontinuously
red : the link is deleted.
TRANSMITTER
TR RECEIVER
ON
OFF
GreenxedLED
Pressingpush-buttonA(fct)
RedxedLED
Pressingpush-buttonA(fct)
PressMENU,
Cursorunder
ashes Thermostat
regulates the
heating.
Press ashes To change from
Heatingmodeto
Air-conditioning
mode.
Press
MENU
Tocancel&
return to Auto
mode

PA:9 OptimisationandAnticipation Off,Auto,
1hr,2hr,3hr
OFf Optimisation(Auto-P1oprogram
only).Thermostatautomaticallyesti-
mates the time required to reach the
Comforttemperatureandadjusts
the switch on time. A learning period
of10daysmaybenecessaryto
reach full optimisation. Anticipation
(1hr,2hr,3hr–P4Aprogramonly)
ThisfunctionallowstheComfort
orComfort2 to be applied in
advance.
PA:10 Return to factory settings YEs/nO nO Yes-Reset,No=Noreset
CF9 Radio Links Off/On OFf Off=nocongurationtakingplace
On=congurationtakingplace
CH1=Establishmentofradiolinks
PA:11 ReturntofactoryRFlinksettings YEs/nO nO
Softwareversioninformation
Displayswhichversionofthe
software is installed in the product
Associating the thermostat (transmitter) and receiver
Selectparameter usingthemenukey(1)
GivealongpressonOK:PA:1displays
GiveashortpressonOKuntilCF9(cfg)displays
OFFblinks
Press+,ONblinks
GiveashortpressonOK:CH1(=zone1)displays
Thereceiverswitchestoconguarationmode.LED(C)(cfg)iscontinuouslylitred
Selectthereceivertolink:giveashortpressonbutton(A)(fct)ofthereceiver
LED(B)(fct)blinksred/green
Creationofthelink:givealongpressonbutton(A)(fct)untilLED(C)(cfg)startstoblink,
thenreleasebutton(A)(fct)
LED(B)(fct)blinksred/green,LED(C)(cfg)iscontinuouslyred:thelinkiscreated
CH1(=zone1)ONdisplaysonthetransmitterforseveralseconds
The transmitter and receiver are now paired
Returntoautomaticmode:giveashortpressonthemenukey(1)
5
8
85 mm
remote room thermostat input
remote room thermostat input
ok
–+
Connectionofthethermostatreceivertoa
thermostat input of the boiler.
Connectionofthethermostatreceivertothe
thermostat input of a reversible or irreversible
heat pump.
Connectionofaheatingorairconditioning
circulator.
TRANSMITTER
TT RECEIVER

6 7
Holiday Mode -unitremainspowered,butinactiveexceptforfrostprotection.Thefrostprotection
temperaturecanbeadjustedbetween5degC&30degC.Aholidayperiodcanbesetfrom1-99dayswith
the current day counting as 1.
Parameters
To access all of the parameters press key menu to place the cursor under thengiveonelongpress(>5s)
onOK.
Toonlyaccessparametersfrom(PA:1toPA:4),presskeymenutoplacethecursorunder andconrm
usingtheOKkey.
Press+or–tochangeparametersettingandOKtoacceptandmovetonextparameter.
UserParameterDescription Options Default Notes
PA:1 Defaultdurationoftimedoverride 1,2,3,4,5or
12hours
1hour
PA:2 Backlightingofdisplay OFf/ON ON
PA:3 Temperature
Calibration
+/-3degC 0degC Adjustvaluedisplayedifyou
measure a different ambient to that
the thermostat measures
PA:4 2ndComfort
Temperature level
1or2 1Allowsa2ndcomforttemperature
leveltobeused.Onlyapplicableto
freeprogram(P4)
InstallerParameterDescription
PA:5 Heating/AirConInstallationMode H,CorHC H H=Heating,C=AirConditioningor
HC=ReversibleHeating/Air-Con.
InHCmodecareshouldbetaken
toswitchtheHeatPumpsuitablyfor
the chosen thermostat mode.
PA:6 Degummingthepump OFf/ON OFf Activate/De-activateautomatic
start-up of the pump at
midnight everyday to avoid
jammingduringthesummer.
PA:7 Inertia type of heating installation SLo/FAs FAs SLo=slowinertia
(eg;underoorheating)
FAs=fastinertia
(eg;radiators)
PA:8 Inertia of air-conditioning
installation
SLo/FAs FAs SLo=slowinertia
(eg;underoorcooling)
FAs=fastinertia
(eg;convectorfans)
Initial Set Up & Set Clock Description
PressMENU,cursorunder Yearashing Adjustby+/-
PressOK Monthashing Adjustby+/-
PressOK Dayashing Adjustby+/-
PressOK Hourashing Adjustby+/-
PressOK Minutesashing Adjustby+/-
PressOK(Summer/Wintertimechange) Autoashing AdjusttoOFFby+/-
PressOK(Hourformat) 24Hashing Adjustto12Hby+/-
PressOK Return to Auto mode
Automatic Mode (auto) - operate according to program selected or set.
Manual Mode (manu) - operate as a simple thermostat
PressMENU,cursorunderMANU Programmedprolefordaynotdisplayed AdjustSetTempby+/-
PressMENU,cursorunderAUTO Return to Auto mode
Standby Mode -unitremainspowered,butinactiveexceptforfrostprotection.
PressMENU,cursorunder Programmedproleforday&SetTempnotdisplayed FrostModeActive
PressMENU,cursorunderAUTO Return to Auto mode
Press Daycountashing Adjustby+/-
PressOK FrostTempashing Adjustby+/-
PressOK HolidayModeactive
PressMENU Tocancel&returntoAutomode
CursorunderAUTO Programprolefordaydisplayed
Table of contents
Other Sangamo Thermostat manuals

Sangamo
Sangamo Rstat8 User manual

Sangamo
Sangamo CHOICE RSTAT8 User manual

Sangamo
Sangamo RSTAT1 Guide

Sangamo
Sangamo choice pr 3 User manual

Sangamo
Sangamo CHOICE RSTAT5 Guide

Sangamo
Sangamo CHOICE RSTAT9 User manual

Sangamo
Sangamo RSTAT5 RF Quick start guide

Sangamo
Sangamo Choice Rstat 3 Assembly Instructions

Sangamo
Sangamo Choice RSTAT5 RF User manual

Sangamo
Sangamo Choice RSTAT5 RF User manual
Popular Thermostat manuals by other brands

Eurotronic
Eurotronic SPARmatic premium user manual

ApenGroup
ApenGroup SMART WEB Series Operating, Installation and Programming Manual

Robertshaw
Robertshaw RS9110 installation manual

HaiLin Controls
HaiLin Controls HL8002-MD Series user manual

BN Thermic
BN Thermic W16CW instructions

Nibe
Nibe RMU 40 Installer manual