Summer Time.
Programmable room thermostats need a free ow of air
to sense the temperature, so they must not be covered
by curtains or blocked by furniture. Nearby electric res,
televisions, wall or table lamps may prevent the thermo-
stat from working properly.
Set
Temperature
Day of The
Week
Heating On
Time of Day
Program
Period
Actual Room
Temperature
Programme Settings
Clock Setting
1. Press CLOCK button once, year ashes, press +or -
buttons to set year.
2. Press CLOCK button again, month ashes, press +
or -buttons to set month.
3. Press CLOCK button again, day ashes, press +or -
buttons to set day.
4. Press CLOCK button again, hour ashes, press +or -
buttons to set hour.
5. Press CLOCK button again, minute ashes, press +
or -buttons to set minute.
6. Press SET button to conrm, or just wait 15 seconds,
it will be conrmed automatically.
Program Setting/Review
1. Default program values are:
6. Press PROG button again to display P2 and clock
ashes. Set P2–P6 same as P1
7. After setting P6, press PROG button and the current
day or day group (1-7) will ash again. Return to step 2
to program other days.
8. After setting all programs, press SET button to con-
rm or wait 15 seconds to conrm automatically.
9. In normal running status, you can press the PROG
button to review program information for current day or
day group.
If current day only is shown initially (Unit is programmed
for 7 day cycle).
If day group (1-7) is shown (Unit is programmed for a
24 hour cycle).
Press +or -buttons to change the day to be reviewed.
Copy function
1. Hold COPY button for 3 seconds to display COPY and
day 1 ashes
2. Press +or -buttons to select the day which you want
to copy from, then press COPY button once, the day will
stop ashing.
3. Press +or -buttons to select the day which you want
to copy to, press COPY button once to complete.
4. Press +or -buttons to select next day you want to
copy to, press COPY button again to complete.
5. Repeat above steps to nish, then press SET button to
conrm, or you can wait 15 seconds, it will be conrmed
automatically.
Permanent Hold: Temperature is held indenitely
until user cancels
Press HOLD button once to display symbol,
Press +or -buttons to set the temperature, press PROG
button once.
Then press SET button to conrm or you can wait 15
seconds to conrm automatically.
The setting will be kept until you exit by pressing SET
button.
If 1-7 are all selected then the 24hour cycle option is
active– each days programs will be the same.
If either of 1,2,3,4,5,6,7 is selected then the 7 day cycle
option is active – each days programs can be different.
Dependant on your lifestyle, these default pro-
gram settings may be satisfactory.
2. Hold SET button, then press PROG button once , the
current day or day group (1– 7) will ash;
3. Press +or -buttons to change the day group (1-7) to
individual day to be set (1, 2, 3, 4, 5, 6, 7)
4. Press PROG button once to display P1 and clock
ashes, press +or -buttons to set time (increment
10 minutes)
5. Press PROG button again and temperature ashes,
press +or -buttons to set temperature (increment
0.5°C)
Day Group Cycle P1 P2 P3 P4 P5 P6
1-7 (default) 24hr 6:30 21°C 8:00 18°C 12:00 21°C 14:00 18°C 18:00 21°C 22:30 16°C
1,2,3,4 & 5 7 Day 6:30 21°C 8:00 18°C 12:00 21°C 14:00 18°C 18:00 21°C 22:30 16°C
6 & 7 7 Day 8:00 21°C 10:00 21°C 12:00 21°C 14:00 21°C 18:00 21°C 23:00 16°C
Hold Days: Temperature is held for a number of
days before returning to the programs
Hold HOLD button for 3 seconds to display d:01 and
symbol.
Press +or -buttons to select holding days from d:01
to d:99, then press PROG button once.
Then press SET to conrm or you can wait 15 seconds
to conrm automatically.
Press +or -buttons to set override temperature.
The setting will be kept until nished the holding days,
or you can press SET button to exit manually.
Hold Hours: Temperature is held for a number of
hours before returning to the programs
Press +or -buttons to set temperature,
Press CLOCK button, then +or -buttons to select time
range from 1 – 9 hours. Press PROG button.
Then press SET button to conrm or you can wait 15
seconds to conrm automatically.
The setting will be kept until nished the holding hours,
or you can press SET button to exit manually.
Hold until next program: Make a temporary
change to the temperature
Press +or -buttons to set temperature, press PROG
button once.
Then press SET button to conrm or you can wait 15
seconds to conrm automatically. The setting will be
kept until next program, or you can press SET button to
exit manually.
Set Temporary Temperature Default Settings :
Temperatures initially offered when + or - buttons
are pressed
Default temperatures when rst pressing the +or -
buttons
Hold SET and press + button once to ash 22.0°, press
+or -button to set temporary override temperature (7
- 35°C, default is 22°C).
Hold SET and press - button once to ash 18.0°C, press
+or -button to set temporary override temperature (7
- 35°C, default is 18°C).
SET button to conrm, or just wait 15 seconds, it will
be conrmed automatically
Additional Instructions
Switching Differential (on/off control) : The
tolerance from the set temperature before the
measured temperature signals the thermostat to
switch its output.
Press CLOCK button once, then press COPY button once
to display S: 1, press +or -buttons to change between
S:1 or S: 2, then press SET button to conrm.
S: 1: differential is ±0.2°. When room temperature is
-0.2°C below setting temperature, it will display
symbol and boiler will turn on. When room temperature
is +0.2°C above setting temperature, symbol will
disappear and relay will turn off.
S: 2: differential is +0°C or -0.2°. When room
temperature is -0.2°C below setting temperature, it
will display symbol and boiler will turn on. When
room temperature is reached, i.e. +0.0°C, symbol will
disappear and relay will turn off.
LCD Back-light Operation
Press LIGHT button to turn on back-light. It will turn off
without pressing in 15 seconds.
Receiver Operation
1. Press MANUAL button once, green LED is on, that
means it enters into manual status.
2. Press M/A button once, red LED is on and relay turns
on.
3. Press M/A button again, red LED is off and relay turns
off.
4. Press MANUAL button, green LED is off, it returns to
auto status.
Reset
1. Reset software: Press RESET button to return to
default values.
2. Reset hardware: Press SW11 key on the PCB to reset
the thermostat. The program settings are retained.
Transmitter
Power supply : 2xAA 1.5V batteries
Battery lifespan : 1 year
Temperature display range: 5-40° (increment 0.1)
Temperature control range: 7- 35°C (increment 0.5)
Program time increment: 10 minutes
Temperature accuracy: +/-1°C
Switching differential: +/-0.2°C or +0/-0.2°C
Operating temperature: 0 - 45°C
Clock accuracy: <1sec / day
Protection rating: IP30
Dimensions: 135 x 89 x 32mm
Transmission frequency: 868.35Mhz
Specication
signal automatically sent every 9minutes
Transmission distance ; 80m open, 30m indoors
Mounting : Wall or free standing using table
stand.
Receiver
Power supply : 230Vac, 50Hz
Contact rating ; 6(2), 250Vac(Volt Free contact)
Insulation class ; 2
Flexible wire size : 0.5-1.5mm
Rigid wire size : 0.5-2.5mm
Dimensions : 85x85x38mm
Wall mounting : Industry standard wall-plate
Approval Standards
EN60730-1
EN60730-2-7
EN60730-2-9
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become
defective please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental
recycling, recovery and/or disposal. End of life products should be handled in line with local regulations.
Alternatively return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This
means we welcome your comments and complaints, as it can help us to improve our services to you, our
customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be
subject to change without prior notice.
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Web: www.sangamo.co.uk
WEE/JH0069TY143762 Issue A
If you have a problem or require
any further information please
contact our technical team on:
01475 745131