Sangamo CHPRSTATDP User manual

Features1
Operation Guide
2
CHPRSTATDP is an accurate and very easy to use programmable
room thermostat. It provides you with time and temperature control,
so you remain comfortable but without wasting energy (and money).
24 hour or 7 day programmable
6 time/temperature events per day
Default adjustable program
Permanent hold temperature
Timed hold temperature
Temporary temperature override
Automatic Summer/Winter time change
Low battery voltage indication
Button press back-light operation
TPI control
Optimum Start/Delay Start, Optimum Stop
Open the front cover to show the hidden panel (as below), and
complete all the settings as per below operation guide.
The display will show Cr(cycle rate), within the control proportional
band, the output will be cycled several times per hour, to give precise
Before you set the thermostat, you should fix the time and date
Press and hold Set for 6 seconds.
Choose between °F and °C using+-and press Ok(°C as default).
Choose between 24hr and 12hr clock using+-and press Ok.
Set the Year using+-and press Ok.
Set the Month using+-and press Ok.
Set the Day using+-and press Ok.
Set the Hour using+-and press Ok.
Set the Minute using+-and press Ok.
Choose between 0.5°C and 1.0°C switching differential using+-
and press Ok.
Remark: Cycle Rate & Proportional band settings are only
required at initial installation.

1
The latest ESP product manuals
can be found on-line:
CHPRSTATDP
Digital Programmable Thermostat
User Instructions
4 dashes appear on the display, this can be used to set a reminder
to replace filters in an air conditioning system, press Ok to skip this.
So the thermostat do not need to turn on the load in advance, it only
needs to keep the temperature as 15.5℃after 8.30am.
The CHPRSTATDP comes preset with a default program so that
you can get up and running straight away. Each day is split into 6
parts. Each one can have its time or temperature changed to suit you.
When the DIP switch is set to Optimum Start, the default program
is as the Chart 1 below.Chart 1 shows the target time and target
temperature(i.e.when you require to be warm ).
When The DIP switch is set to Delayed Start, the default program
is as the Chart 2 below.Chart 2 shows the earliest start time and
target temperature. If the temperature of the previous program is
higher, the next program time means the target time. For example ,
the MORN temperature is 21℃, and the Day temperature is 15.5℃.
Press Ok to return to Run Mode.
1. SETTING THE TIME, DATE and PARAMETERS:
2. DEFAULT PROGRAM:
Within programming mode the thermostat will return to normal
operation if no buttons are pressed for 30 seconds.To exit
programming mode either wait 30 seconds or press Set x2 and Ok.
NB: Each day's end time is 11:59 in 12hr or 23:59 in 24hr formats.
P6 cannot be set for midnight.Each day of the week can be
programmed separately, starting with Monday (Mo) .
Press Set to enter programming mode.
Set Mo MORN temperature using+-and press Ok.
Set Mo MORN time using+-and press Ok.
Set Mo DAY temperature using+-and press Ok.
Set Mo DAY time using+-and press Ok.
Repeat procedure for all 6 set points in the day and continue on to
program each day of the week.
At any point Press Set x2 then Ok to return to Run Mode.
3. PROGRAMMING:
temperature control. This can be set to 3, 6 or 12 cycles depending
on the application, every cycle rate matches with different Minimum
ON/OFF time.Recommended settings and Cycle rate vs. Minimum
ON/OFF time are shown in the next table. The default cycle rate is 6
cycles/hour,set the Cycle Rate using+-and press Ok.
The display will show Pb(proportional band width),the default
proportional band width is 1.5 °C , set the proportional band width
using+-(from1.5 °C to 3.0 °C).
Specific Applications Setting
Cycle Rate Minimum ON/OFF(min)
Gas Boiler(<30 kw)
Oil Boiler
61
34
12 1
61
34
34
Thermal actuator
Zone Valve
Heat pump
Air Conditioner
Recommended
Settings
Mo-Fr Time ℃
1:MORN
2:DAY
3:Noon
4:Break
5:EVEN
6:NIGHT
6:00am
8:30am
12:00pm
2:00pm
4:30pm
10:30pm
21℃
15.5 ℃
21℃
15.5 ℃
21℃
18.5 ℃
Sa-Su Time ℃
1:MORN
2:DAY
3:Noon
4:Break
5:EVEN
6:NIGHT
7:00am
8:30am
12:00pm
2:00pm
4:30pm
10:30pm
21℃
21℃
21℃
21℃
21℃
18.5 ℃
Mo-Fr Time ℃
1:MORN
2:DAY
3:Noon
4:Break
5:EVEN
6:NIGHT
5:00am
8:30am
11:00am
2:00pm
3:30pm
10:30pm
21℃
15.5 ℃
21℃
15.5 ℃
21℃
18.5 ℃
Sa-Su Time ℃
1:MORN
2:DAY
3:Noon
4:Break
5:EVEN
6:NIGHT
6:00am
8:30am
12:00pm
2:00pm
4:30pm
10:30pm
21℃
21℃
21℃
21℃
21℃
18.5 ℃
Chart 1
Chart 2
140mm
88.6mm
Ok
Set M
Reset
To speed up the programming sequence you can copy one day into
another, or several other days.
Press Set x2 to enter copy mode.
Choose the 'Copy' day using+and press Ok.
Choose the 'Paste' day using+and press Ok.
Repeat step as required for further 'Paste' days.
At any point Press Ok x2 to return to Run Mode.
2
Health & Safety
Regulations.
proceeding.
may be subject to change without prior notice.
Health & Safety
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring
Regulations.
Isolate mains supply before commencing installation. Please read all installation instructions before
proceeding.
Example circuit diagrams for typical installations are shown. These diagrams are schematic and should
be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For
reasons of space and clarity not every system has been included and the diagrams have been simplified,
for instance some Earth connections have been omitted. Other control components shown in the
diagrams i.e. Valves, Room Stats etc. are general representations only. However, the wiring detail can
be applied to the corresponding models of most manufacturers.
Your product is not user serviceable. Do not dismantle this product.
Due to our policy of continuous product improvement and development, the specifications in this guide
may be subject to change without prior notice.
Elite Security Products
Unit 7, Target Park, Shawbank Road,
Lakeside, Redditch, B98 8YN
Tel: 01527 515150
Fax: 01527 515143
Email: [email protected]
Web: www.espuk.com
4. COPY/PASTE DAY:
To manually change the temperature temporarily you simply press
the raise or lower buttons to the desired level, if left alone this will
stay set until the next programmed change at which point it returns
back to the original schedule.
Choose desired temperature using+-and press Ok.
To cancel setting early and return to normal operation press Ok.
5. CHANGE THE TEMPERATURE:
You can also set the thermostat to hold at the temperature you want
for a defined number of hours.
Press M to enter override mode then select temperature using+-
and press Ok.
Select number of hoursusing+-(max 23 hours) and press Ok.
Comfort Override, Temp. Set & Hours, with the hours remaining,are
shown on the display.
To cancel setting and return to normal operation press Ok.
6. CHANGE THE TEMPERATURE FOR A SET NUMBER OF HOURS:
Hold the thermostat at a desired temperature until manually
cancelled by you.
Press M x2 to enter permanent override mode then select tem-
perature using+- and press Ok.
Permanent Hold and Temp. Set are displayed.To cancel setting
and return to normal operation press Ok.
7. HOLD TEMPERATURE PERMANENTLY:
Hold the temperature at a desired set point until a specific date.
Press M x3 to enter holiday mode then select temperature using+-
and press Ok.
Select the Month and Year using+-and press Ok.
Select the Day using+-and press Ok.
Hold Temp Until, Temp. Set & Hours are displayed.
To cancel setting and return to normal operation press Ok.
To erase all current settings and return to it’s factory default settings
& programs.
Press and hold Ok and-for 6 seconds.
When Reset is displayed push in the Reset button.
All segments on the display are shown to confirm reset has taken
place.
8. HOLIDAY MODE:
9. RESET UNIT:
Date Issued
J20 A30-CHPRSTATDP-01-2 Rev.1
Issue No Description

Other Sangamo Thermostat manuals

Sangamo Choice RSTAT5 RF User manual

Sangamo

Sangamo Choice RSTAT5 RF User manual

Sangamo CHPWIFI User manual

Sangamo

Sangamo CHPWIFI User manual

Sangamo Rstat8 User manual

Sangamo

Sangamo Rstat8 User manual

Sangamo CHOICE RSTAT5 Guide

Sangamo

Sangamo CHOICE RSTAT5 Guide

Sangamo RSTAT1 Guide

Sangamo

Sangamo RSTAT1 Guide

Sangamo Choice RSTAT5 RF User manual

Sangamo

Sangamo Choice RSTAT5 RF User manual

Sangamo choice pr 3 User manual

Sangamo

Sangamo choice pr 3 User manual

Sangamo Choice Rstat 7 Guide

Sangamo

Sangamo Choice Rstat 7 Guide

Sangamo CHOICE RSTAT9 User manual

Sangamo

Sangamo CHOICE RSTAT9 User manual

Sangamo RSTAT5 RF Quick start guide

Sangamo

Sangamo RSTAT5 RF Quick start guide

Sangamo CHOICE RSTAT8 User manual

Sangamo

Sangamo CHOICE RSTAT8 User manual

Sangamo Choice Rstat 3 Assembly Instructions

Sangamo

Sangamo Choice Rstat 3 Assembly Instructions

Popular Thermostat manuals by other brands

Theben RAMSES 831 top operating instructions

Theben

Theben RAMSES 831 top operating instructions

Silvercrest Classic Model L Operating instructions and safety advices

Silvercrest

Silvercrest Classic Model L Operating instructions and safety advices

Sears 1F86-382 Nstallation and operating instructions

Sears

Sears 1F86-382 Nstallation and operating instructions

Salus RT510LG5V quick guide

Salus

Salus RT510LG5V quick guide

DIVERSITECH 675-TS32 instruction manual

DIVERSITECH

DIVERSITECH 675-TS32 instruction manual

Homematic IP HmIP-WTH-B-2 Installation and operating manual

Homematic IP

Homematic IP HmIP-WTH-B-2 Installation and operating manual

Honeywell Home CM900 installation guide

Honeywell Home

Honeywell Home CM900 installation guide

Worcester DT10RF Operating and installation

Worcester

Worcester DT10RF Operating and installation

Honeywell CT62A installation instructions

Honeywell

Honeywell CT62A installation instructions

Braeburn 7300 user manual

Braeburn

Braeburn 7300 user manual

Honeywell RTH1100 series operating manual

Honeywell

Honeywell RTH1100 series operating manual

HomeMatic HMIP-WTH Mounting instruction and operating manual

HomeMatic

HomeMatic HMIP-WTH Mounting instruction and operating manual

Hunter 44259 owner's manual

Hunter

Hunter 44259 owner's manual

Siemens RDF302/VB manual

Siemens

Siemens RDF302/VB manual

Habitat HTE-01 Operation manual

Habitat

Habitat HTE-01 Operation manual

Honeywell CT62A installation instructions

Honeywell

Honeywell CT62A installation instructions

REMKO ATR-4 operating instructions

REMKO

REMKO ATR-4 operating instructions

Honeywell t7100f installation instructions

Honeywell

Honeywell t7100f installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.