manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Santec
  6. •
  7. Plumbing Product
  8. •
  9. Santec KLASSICA 9570KL User manual

Santec KLASSICA 9570KL User manual

KLASSICA COLLECTION
MODEL: 9570KL
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
Important : Please register your product online at www.santecfaucet.com within
30 days of purchase. Santec reserves the right to request additional documents
before servicing warranty requests.
0 1
MODEL: 9570KR
MODEL: 9570KT
BIDET
02
Vacuum Breaker
NOTE: See diagram on next page for removing and reinstalling the
complete trim.
Remove the complete trim from the Vacuum Breaker valve.
Insert Vacuum Breaker valve up from below and reinstall complete trim
except for the handle cap. Make sure to install the black plastic lock
nut in the position shown in the diagram on the next page. Snugly
tighten down the black plastic lock nut and trim cylinder by hand
tightening only.
until it stops. Pop the handle cap into the handle with the “spritzer”
icon facing frontwards or at the 6 o’clock position (see handle cap
diagram below).
supply lines.
Hole size for the spout and Handle Trim is a minimum of 1-1/4” and a
maximum of 1-1/2”.
Vacuum Breaker Installation
6
1 2
3
9
Spritzer
Handle Cap
9570 KL, KR, KT _ _
03
9570 KL, KR, KT _ _
Black plastic lock nut
Trim Cylinder
Handle
Screw
Handle Cap
Black Soft Seating China Seals
Black Soft Seating China Seals
White Nylon Slip Washer
Vacuum Breaker Valve
Elbow
Wye
Complete Trim
04
9570KL, KR, KT _ _
Handle Tr i m
Remove the Valve Body Mounting Hardware from the valve body. Slip
appropriate hole next to the vacuum breaker (HOT-left & COLD-right).
Apply a ring of silicone caulking around the handle hole on the bidet
top. DO NOT USE PLUMBER’S PUTTY, WHICH CAN DAMAGE FINISH.
Connecting Hoses toward Wye Connector.
For proper handle turning direction, install the handle with the “COLD”
blue label at the right side of the sink (front view) and the handle with
the “HOT” red label at the left side of thesink.
HANDLE TRIM IS READY FOR DROP-IN INSTALLATION. DO NOT
DISASSEMBLE HANDLE TRIM.
Handle Trim Installation (1)
Valve Body
Mounting Hardware
Washer
Brass Lock Nut
Wye connecting hoses
0 5
9570KL, KR, KT _ _
From beneath of the bidet, screw the Valve Body Mounting Hardware
back onto the valve body. First the washer, then the brass locknut.
Align the lever or cross handle properly against the vacuum breaker
the Inlet Hoses to the Supply Lines. Tighten to avoid leakage.
Handle Tr i m
Washer
Brass lock nut
Handle Trim Installation (2)
Inlet Hose
Supply Line
0 60 6
9570KL, KR, KT _ _
Sprit z e r
Apply a ring of silicone caulking around the hole designated for Spritzer
Slip Spritzer through the appropriate hole in bidet. From underneath
attach the Rubber Washer, Metal Washer and Shank Lock Nut. Tighten
Attach 24” hose from Spritzer to bidet elbow and tighten both ends
Spritzer Installation
Bidet
Basin
Rubber washer
Shank lock nut
Metal washer
Housin g
Basket
Wash e r
Spritzer Assembly
Spritzer
Front View
07
9570KL, KR, KT _ _
Pop U p Drai n
Remove Drain Flange and Drain Plug from pop-up assembly.
Apply a ring of silicone caulking to underside of Drain Flange. Do not use
Insert the threaded end of the assembly up from below and into thepop up
drain hole.
Completely thread the drain body into the Drain Flange and align with the Ball
Rod Hole facing back. Then tighten lock nut from below. Clean excess silicone
with paper towel.
Pop Up Drain Installation (1)
Drain Plug
Drain Flange
Ball Rod Hole
Gasket
Washer
Lock nut
08
9570KL, KR, KT _ _
Remove the Brass Lock Nut, Rubber Washer and Metal Washer from the
lift rod assembly. Inser t Lift Rod Flange into designated hole and
reassemble the Metal Washer, Rubber Washer and Brass Lock Nut from
below the bidet basin. Firmly tighten the Brass Lock Nut to secure Lift
Rod Flange.
Insert theLift Rod into Lift RodFlange from above.
Pop Up D rai n
PopUpDrainInstallation(2)
Metal Washer
Rubber Washer
Brass Lock Nut
Lift Rod
Lift Rod Flange
09
9570KL, KR, KT _ _
Insert Drain Plug into Drain Flange. Make sure the adjustable eye-screw
it.
Insert Ball Rod Washer into drain body followed by the Ball Rod, 2nd
Washer and Ball RodNut. Tighten the Ball Rod Nut until snug.
Gently push the Horizontal Ball Rod down to place the plunger in the
up position.
Connect the Lift Rod with the Ball Rod using the Pop-up connection and
tighten securely with screwdriver.
Test Pop-up for smoothoperation and adjust if necessar y.
Drain plug
Drain tube
Lift rod
Pop-up connection
Pop UpDr a i n
PopUpDrainInstallation(2)
Ball rod
assembly
(ball rod, ball rod
nut, & 2 washers)
10
9570KL, KR, KT _ _
Flu s h T h e Lin e
After all connections have been made from inlet supplies to angle
stops, remove Spritzer Housing, Basket and Washer (see Spritzer
Installation on page 5).
Open both hot and cold valves. Slowly open angle stops from below
Turn water off and reinstall Spritzer Housing, Basket and Washer.
INLET HOSEINLET HOSE
WARNING
: Do not clean yourSANTECproduct with ammonia (Window cleaner), bleach, soaps, acids,
abrasives, harsh polishes, harsh cleaners, a coarse surfaced cloth, coarse sponge, or any type of scouring
Polished & Satin 24K Gold:
The Karat mark states the percentage of pure gold -- 24K is 100 percent gold. As one of
the Earth's most precious metals, gold is the most supple and malleable of all metals. Gold-plated faucets scratch easily. To
clean, wipe down with a dry soft cloth after each use. Gold surfaces should be coated with a thin layer of non-abrasive carnauba
wax or liquid car wax up to 3 or 4 times per year. This will prevent water spotting and water deposit buildup. We recommend
using SANTEC’s Polish which has been formulated to clean and seal, leaving behind a protective coating that will resist
tarnishing and improvewater repellency.
Antique Bronze :
Antique bronze simulates the antiquity of Old-World craftsmanship with a golden base color and a blend
of dark undertones. To clean, wipe down with a dry soft cloth after each use. Antique Bronze should be coated with a thin layer
of non-abrasive carnauba wax or liquid car wax up to 3 or 4 times per year. We recommend using SANTEC’s Polish which has
been formulated to clean and seal,leavingbehind a protectivecoating that will resist tarnishing andimprove water repellency.
Oil Rubbed Bronze :
Oil-rubbed bronze simulates the antiquity of Old-World craftsmanship with its warm, dark brown
color and copper undertones. To clean, wipe down with a dry soft cloth after each use. Oil-rubbed bronze should be coated with
a thin layer of non-abrasive carnauba wax or liquid car wax up to 3 or 4 times per year. We recommend using SANTEC Polish
which has been formulated to clean and seal, leaving behind a protective coating that will resist tarnishing and improve water
repellency.
Polished Chrome:
use. A non-abrasive all-metal cleaner can then be applied to restore the shine. The surface can also be coated with a thin layer of non-abrasive
carnauba wax or liquid car wax. This will prevent water spotting and water deposit buildup. We recommend using SANTEC’s Polishwhich
has been formulated to clean and seal, leaving behind a protective coating that will resist tarnishing and improve water repellency.
Polished and Satin Nickel
Thank you for making SANTEC a part of your lifestyle and luxury spa experience. Our products have been created as works of
CLEAR CO ATED F I N ISHES
N O N-CLEAR COATED FINISHE S
FINISH CARE INFORMATIO N
PLEASE REGISTER YOUR PRODUCT ONLINE FOR WARRANTY SERVICES
www.santecfaucet.com/registration
SANTEC
SANTEC
A non-abrasive all-metal cleaner can then be applied to restore the shine. The surface can also be coated with a thin layer of non-abrasive
carnauba wax or liquid car wax. This will prevent water spotting and water deposit buildup. We recommend using SANTEC’s Polishwhich
has been formulated to clean and seal, leaving behind a protective coating that will resist tarnishing and improve water repellency.
:
use.
This warranty does not cover:
SANTEC res
erves the right to examine any product claimed defective prior to any warranty claim being accepted or processed,
o
state.
Damage due to negligence, accident, abuse, improper installation, or improper maintenance such as, but not limited to: heat
from soldering during installation, the use of plumber’s putty, damage from tools used during installation, the use or exposure
to chemicals or cleaning products either abrasive or non-abrasive, or the use of any cleaning tool or product other than a
altered or used in a manner not typical for the product.
Loss, damages, or expense, incidental or consequential whatsoever, originating from the purchase, installation, use, repair,
failure, or replacement of any
SANTEC pro
ductorpart, allowed by law.
Commercial and/or Industrial installationsand use of the product.
This warranty does not include labor, travel charges, or any costs incurred for repair, removal, installation, servicing,
diagnosing, or handling of either defective or replacement parts.
1.
2.
3.
4.
5.
SANTEC is committed to enhancing your bathroom experience by creating luxury products that will provide enduring
satisfaction. Every effort has been made to satisfy the highest standards of design and production, to create lasting peace of
mind for our customers. We provide the following limited warranties on ourproducts:
Limited Warranty against all manufacturer’s defects and tarnish.
Finishes:
Mechanical:
A Lifetime Limited Warranty is provided on parts to be free from failure related to defects in materials and
workmanship.
SANTEC
cartridges carry a Five (5) Year Limited Warranty against manufacturer’s defects.
This warranty extends to the original consumer purchaser only and extends for as long as the original purchaser owns the
product and the home in which the product is installed.
Please read ‘WHAT IS COVERED BY OUR WARRANTY’ and ‘EXCLUSIONS AND LIMITATIONS OF WARRANTY’ sections to
understand what is and what is not covered.Please have ready the proof of purchase (original sales receipt), description of the
problem, and carefully package the product or defective part with postage prepaid. Then, please contact your local
SANTEC
Showroom or write to
SANTEC
Technical Services.
LIFET I ME LIMITE D WARRANTY
LENGTH OF WA RRANTY & WHO IS COVERED BY O U R WARRANTY
WHAT IS COVERED BY OUR WA RRANTY
EXCLUSIONS ANDLIMITATIONS OF WARRANTY
TO OB TAIN WARRANTY SERVICE
SANTEC
Access should be provided to the roman tub valves for future service or repair to valves and piping. Under no
circumstances will Santec Faucet, Inc. be liable for anycosts associated with the removal of materials for future
access to the tub valves or piping for service or repair.

This manual suits for next models

2

Other Santec Plumbing Product manuals

Santec EBIS E Series User manual

Santec

Santec EBIS E Series User manual

Santec FLUID IMAGINATION CHADWICK 4320GL User manual

Santec

Santec FLUID IMAGINATION CHADWICK 4320GL User manual

Santec E-Series User manual

Santec

Santec E-Series User manual

Santec ATHENA 3450HO-TM User manual

Santec

Santec ATHENA 3450HO-TM User manual

Santec TH-8010 User manual

Santec

Santec TH-8010 User manual

Santec Enzo 3655EN-TM User manual

Santec

Santec Enzo 3655EN-TM User manual

Santec E-Series User manual

Santec

Santec E-Series User manual

Santec Caprie 9470EZ User manual

Santec

Santec Caprie 9470EZ User manual

Santec 7089SE User manual

Santec

Santec 7089SE User manual

Santec E-Series User manual

Santec

Santec E-Series User manual

Santec Barosa 2429MC User manual

Santec

Santec Barosa 2429MC User manual

Santec TH-8010 User manual

Santec

Santec TH-8010 User manual

Santec FLUID IMAGINATION BRAVO 6620BO User manual

Santec

Santec FLUID IMAGINATION BRAVO 6620BO User manual

Santec E-Series User manual

Santec

Santec E-Series User manual

Santec AVA Series User manual

Santec

Santec AVA Series User manual

Santec Heritage I 2970EY User manual

Santec

Santec Heritage I 2970EY User manual

Santec FLUID IMAGINATION Lutti 4820PT User manual

Santec

Santec FLUID IMAGINATION Lutti 4820PT User manual

Santec KARLIE 1870EP User manual

Santec

Santec KARLIE 1870EP User manual

Santec Athena 3470HO User manual

Santec

Santec Athena 3470HO User manual

Santec BAROSA 2455MC-TM User manual

Santec

Santec BAROSA 2455MC-TM User manual

Santec ESTATE 6665BO10 User manual

Santec

Santec ESTATE 6665BO10 User manual

Santec Widespread 9220ED User manual

Santec

Santec Widespread 9220ED User manual

Santec ENZO COLLECTIONS 3670EN User manual

Santec

Santec ENZO COLLECTIONS 3670EN User manual

Santec MONARCH CRYSTAL Series User manual

Santec

Santec MONARCH CRYSTAL Series User manual

Popular Plumbing Product manuals by other brands

Moen T6620BN manual

Moen

Moen T6620BN manual

American Standard 2798 Series parts list

American Standard

American Standard 2798 Series parts list

Sterling Plumbing 71140115 Specification sheet

Sterling Plumbing

Sterling Plumbing 71140115 Specification sheet

Hans Grohe Croma 160 27450000 Assembly instructions

Hans Grohe

Hans Grohe Croma 160 27450000 Assembly instructions

Leisure Sinks Velstra Installation details

Leisure Sinks

Leisure Sinks Velstra Installation details

Delabie 130320 manual

Delabie

Delabie 130320 manual

Bradley Express MG-2/NDT Installation

Bradley

Bradley Express MG-2/NDT Installation

abi 14404 quick start guide

abi

abi 14404 quick start guide

Toto NEOREST MS990CG instruction manual

Toto

Toto NEOREST MS990CG instruction manual

Schell LINUS D-C-T Assembly instructions

Schell

Schell LINUS D-C-T Assembly instructions

Presenza Milan QF45BR user manual

Presenza

Presenza Milan QF45BR user manual

American Standard One Spread Lavatory Faucet 2064.408 installation instructions

American Standard

American Standard One Spread Lavatory Faucet 2064.408 installation instructions

Villeroy & Boch ProDetect 2 installation instructions

Villeroy & Boch

Villeroy & Boch ProDetect 2 installation instructions

Glacier bay 67099-0A01 Installation and care guide

Glacier bay

Glacier bay 67099-0A01 Installation and care guide

Kohler K-72218 Installation and care guide

Kohler

Kohler K-72218 Installation and care guide

Toto MONO TX116LMN quick start guide

Toto

Toto MONO TX116LMN quick start guide

Omnires AD5115BR Installation and Maintenance

Omnires

Omnires AD5115BR Installation and Maintenance

Graff 7090 installation instructions

Graff

Graff 7090 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.