manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Santon
  6. •
  7. Water Heater
  8. •
  9. Santon Aquarius AU7/3 Guide

Santon Aquarius AU7/3 Guide

This manual suits for next models

3

Other Santon Water Heater manuals

Santon Premier Plus 120 User guide

Santon

Santon Premier Plus 120 User guide

Santon PremierPlus User guide

Santon

Santon PremierPlus User guide

Santon Aquaheat SS V 100 Guide

Santon

Santon Aquaheat SS V 100 Guide

Santon Power Pack HP/S Assembly instructions

Santon

Santon Power Pack HP/S Assembly instructions

Santon Aqualine ALK02 User manual

Santon

Santon Aqualine ALK02 User manual

Santon Aquaheat AH30V Guide

Santon

Santon Aquaheat AH30V Guide

Santon SP2.5 Guide

Santon

Santon SP2.5 Guide

Santon PremierPlus 100 User guide

Santon

Santon PremierPlus 100 User guide

Santon EV 2008 Guide

Santon

Santon EV 2008 Guide

Santon A7/3 Guide

Santon

Santon A7/3 Guide

Santon PowerPack Guide

Santon

Santon PowerPack Guide

Santon Aquarius A7/3 Guide

Santon

Santon Aquarius A7/3 Guide

Santon Aquarius AU7/3 Guide

Santon

Santon Aquarius AU7/3 Guide

Santon PowerPack User manual

Santon

Santon PowerPack User manual

Santon PREMIER PLUS User guide

Santon

Santon PREMIER PLUS User guide

Santon AH7/2.2 Guide

Santon

Santon AH7/2.2 Guide

Santon SP2.5 Guide

Santon

Santon SP2.5 Guide

Santon PES170D User guide

Santon

Santon PES170D User guide

Santon PP100E User guide

Santon

Santon PP100E User guide

Santon AL07/3 Guide

Santon

Santon AL07/3 Guide

Santon EV 2008 Guide

Santon

Santon EV 2008 Guide

Santon R25 Guide

Santon

Santon R25 Guide

Santon AH10/2.2 Guide

Santon

Santon AH10/2.2 Guide

Popular Water Heater manuals by other brands

clage German pool CEX13 operating instructions

clage

clage German pool CEX13 operating instructions

Noritz proTough NR98SV installation manual

Noritz

Noritz proTough NR98SV installation manual

DeDietrich KALIKO TWH 200 EV Installation and service manual

DeDietrich

DeDietrich KALIKO TWH 200 EV Installation and service manual

veito FLOW Installation and operating instructions

veito

veito FLOW Installation and operating instructions

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

ICI Caldaie

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

Savio Laser 11 A Instruction manual for installation and use

Savio

Savio Laser 11 A Instruction manual for installation and use

Kenmore 153.582400 Use & care guide

Kenmore

Kenmore 153.582400 Use & care guide

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

clage E-Mini Series Operating and installation instructions

clage

clage E-Mini Series Operating and installation instructions

Solar SunX 317365-002 instruction manual

Solar

Solar SunX 317365-002 instruction manual

Bradford White EF Series Service manual

Bradford White

Bradford White EF Series Service manual

Dimplex ECSd125-580 Installation and user instructions

Dimplex

Dimplex ECSd125-580 Installation and user instructions

Dux 32FCR6N installation manual

Dux

Dux 32FCR6N installation manual

Noritz N-132M Owner's guide and installation manual

Noritz

Noritz N-132M Owner's guide and installation manual

TESY GCV7/4S 10047 Instructions for use and maintenance

TESY

TESY GCV7/4S 10047 Instructions for use and maintenance

A.O. Smith Gphe 50 instruction manual

A.O. Smith

A.O. Smith Gphe 50 instruction manual

Rinnai REP199i Installation and operation manual

Rinnai

Rinnai REP199i Installation and operation manual

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

Toyotomi

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Hurricane Way,
Norwich
Norfolk, NR6 6EA.
www.santon.co.uk
Installation and User Instructions
Aquarius Undersink Vented Water Heaters
Models: AU7/3, AU7/1, AU10/3, AU10/1.
Customer Service:
Tel: (0844) 8711530
Fax: (0844) 8711528
Email: [email protected]
Please read and understand these instructions before starting work.
Please leave this leaet with the user following installation
PACK CONTENTS
Heater, Fixing screws and plugs,
Installation and User Instructions, and
Guarantee card.
WARNING
This water heater must only be installed by
competent persons
36005806 Issue 6
Your Aquarius water heater should give you trouble free operation, however, should a problem
occur the table below should enable most faults to be identied with ease.
Fault nding should only be carried out by a competent person and any replacement part should
be authorised Santon spare parts.
SYMPTOM PROBABLE CAUSE ACTION
No hot water 1. Check power Check and replace as necessary.
2. Faulty cut out
3. Faulty thermostat
4. Faulty element
Water too hot 1. Thermostat set to wrong Adjust thermostat.
/cold temperature
2. Faulty thermostat Switch off, check and replace.
No water ow 1. Frozen Switch off electrical power and
allow to thaw at room temperature.
Do not switch on again until full water
ow restored and full checks made for
leaks and electrical safety.
2. No mains supply Check mains.
Continuous water Faulty valve/tap Check and replace.
ow
3.3.7 Secure the cable in the cable grip by tightening the two screws.
3.3.8 Set the adjustable thermostat by rotating the control to the required temperature. It is
recommended that it is set to lowest acceptable temperature to meet user requirements. This
will minimise the risk of scalding and reduce the level of scaling in hard water areas.
3.3.9 Replace terminal cover by locating the hinge at the rear. Slide the snaps into place.
Apply pressure to the front of the cover, pushing back and down until it snaps securely in
place.
4.0 COMMISSIONING
4.1 DO NOT SWITCH ON HEATER UNTIL IT IS FILLED WITH WATER
Fill with water by opening tap and leaving open until a full bore of water ows from
the outlet.
4.2 Switch on water heater at double pole isolating switch. The heater will heat water to
the temperature set on the thermostat.
4.3 Check water is heating correctly.
7 litre 1.2kW - after 10 mins water temperature will increase by 20°C•
7 litre 3kW - after 10 mins water temperature will increase by 60°C•
10 litre 1.2kW - after 10 mins water temperature will increase by 15°C•
10 litre 3kW - after 10 mins water temperature will increase by 40°C•
4.4 Pass instruction leaet to user and draw their attention to the following two statements:
DO NOT USE HEATER IF THE WATER IS THOUGHT TO BE FROZEN•
Switch off immediately at the isolating switch if the water does not ow freely.
Any damage resulting from freezing will not be covered by the guarantee.
DURING HEATING THE OUTLET WILL DRIP•
This is due to the expansion of water inside the heater and is normal for heaters of
this type. It does not indicate that the valve is faulty and over tightening of the valve
can result in damage.
5.0 FAULT FINDING
6.0 SPARE PARTS
In the unlikely event of your Water Heater developing a fault, the following spare parts are
available:
Element plate assembly 7 litre 1.2kW 95 606 902
Element plate assembly 7 litre 3kW 95 606 903
Element plate assembly 10 litre 1.2kW 95 606 904
Element plate assembly 10 litre 3kW 95 606 905
Element plate assembly gasket 95 611 021
Capillary thermostat 95 612 051
Over temperature cut-out 95 612 050
Top cover moulding 95 614 272
Terminal cover 95 614 273
Adaptor long 95 607 954
Adaptor o-ring 95 607 955
Fixing fork 95 607 956
7.0 GUARANTEE
This product is guaranteed against faulty materials and manufacture for a period of 2 years from
the date of purchase provided that:
The unit has been installed in accordance with the Installation and User Instructions and all1.
relevant Codes of Practice and Regulations in force at the time of Installation, and that all
necessary controls and safety valves have been tted correctly.
Any valves and controls are of the Santon recommended type and specication.2.
The unit has not been modied or tampered with in any way, and has been regularly maintained 3.
as detailed in the Installation and User Instructions.
The unit has been used only for heating potable water.4.
The unit is not guaranteed against damage by frost, and the inner container with integral
immersion heater is not guaranteed against excessive scale build-up.
This Guarantee in no way affects the statutory rights of the consumer.
Santon’s policy is one of continuous product development and, as such, we reserve the right to
change specications without notice.
8.0 ENVIRONMENTAL INFORMATION
This product is manufactured from many recyclable materials.
At the end of its useful life it should be disposed of at a Local Authority Recycling Centre in order
to realise the full environmental benets. Insulation is by means of CFC-free polyurethane foam.
This product does not contain any substances harmful to health; it does not contain any asbestos.
©2011
PART OF BDR THERMEA
Thankyou for purchasing a Santon Aquarius water heater. The Aquarius water heater is
manufactured in the UK to the highest standards and has been designed to meet all the latest
relevant safety specications.
This Aquarius water heater must be installed and maintained by a competent person only. Please
read and understand these instructions prior to installing your Aquarius water heater. Particular
attention should be paid to section three headed INSTALLATION. Following installation the
operation of the heater should be explained to the user and these instructions left with them for
future reference.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with
the appliance.
Electrical rating ........................................................... 1.17/1.2kW@230/240V~
2.75/3.0kW@230/240V~
Capacities .................................................................... 7 & 10 litres
Weight ......................................................................... 7 litre - 9.3kg, 10 litre - 12.5kg
Rated Pressure.............................................................. 0Mpa (0bar)
Minimum recommended supply pressure ................... Mains fed or cistern fed
(3m head required)
Temperature range .......................................................10 to 70°C
1.0 INTRODUCTION
2.0 TECHNICAL SPECIFICATION
240 240
57
120
100
X
Y
FIGURE 01: DIMENSIONS
2 KEYHOLE
FIXING SLOTS
FOR UNDERSINK
FIXING
120
3rd FIXING
HOLE
DIMENSION X Y
7 LITRE 356 349
10 LITRE 442 435
3.0 INSTALLATION
3.1 LOCATION
3.1.1 Inlet must always be on the right.
3.1.2 The outlet of this water heater acts as a vent and must not be blocked or restricted in any
way.
3.1.3 Only Santon open outlet accessories must be used with this water heater. A full range is
available, please consult your distributor or Santon for further information.
3.1.4 The installation must be carried out in accordance with the relevant requirements of the
appropriate Building Regulations, either:
The Building Regulations•
The Building Regulations (Scotland) or Building Regulations (Northern Ireland)•
The Water Fittings Regulations or water Byelaws in Scotland•
3.1.5 Select a suitable site but check that:
a) There is enough clearance above the heater to allow for pipe connections and
removal of the element plate.
b) There are no hidden services where the wall is to be drilled.
3.1.6 Mark the position of the xing holes (as shown in Figure 01).
3.1.7 Drill and plug the hole positions.
3.1.8 Screw in the lower two screws leaving heads 3mm from the wall.
3.1.9 Hang the heater on the two screws.
3.1.10 Screw in top screw to secure heater.
3.2 PLUMBING
3.2.1 This water heater is designed for cistern-fed application in conjunction with a separate
cistern and vent pipe (see Figure 02).
3.2.2 Alternatively the heater can be connected directly to the water mains provided that a
Santon ‘vented tap’ is used (see Figure 03).
3.2.3 Both inlet and outlet pipes are clearly labelled. The pipes are 15mm tube and are suitable
for compression ttings.
3.2.4 It is recommended that a WRAS listed isolating valve (not supplied) be tted in the water
supply pipe to the heater to allow for servicing.
3.3 ELECTRICAL
3.3.1 Warning: this appliance must be earthed. It is suitable for a.c. supply only. Electrical
installation must be carried out by a competent electrician and be in accordance with the
latest I.E.E. regulations.
3.3.2 Nominal cross-section of supply cable must be at least 1.5mm2. A double pole isolating
switch with a contact separation of at least 3mm in each pole must be incorporated in the
supply.
3.3.3 Remove the terminal cover using a large at bladed screwdriver to relieve the snaps
located towards the front at either side of the cover. Gripping the cover at the front, pull
upwards.
3.3.4 Strip the outer sheath and insulation on the cable to the required lengths, push the cable
through the grommet provided, this will be held in the cable grip when the connections are
made (see Figure 04).
3.3.5 Pass the cable underneath the cable grip and through the top moulding.
3.3.6 Make the connections to the terminal block as follows:
Live (brown or red wire) to terminal marked “L”•
Neutral (blue or black wire) to terminal marked “N”•
Earth (green or green/yellow wire) to terminal marked .•
HOTCOLD
MAINS
STOP CO CK
SI N K
CI ST ERN
FIGURE 02:
CISTERN FED APPLICATION
FIGURE 03:
OPEN OUTLET APPLICATION
(USING 'VENTED TAP')
MAINS
HOTCOLD
STOP CO CK
VEN T ED H OTTAP
FIGURE 05: WIRING DIAGRAM.
OUTLET
INLET CABLE CLAMP
TERMINAL BLOCK
EARTH POST
ELEMENT
THERMOSTAT CONTROL
FIGURE 04: INTERNAL LAYOUT
THERMAL CUT-OUT
CAPILLARY STAT
TO ELEMENT
GREEN&YELLOW
BROWN/RED
BLUE/BLACK
EARTH
LIVE (RED)
NEUTRAL (BLACK)
THERMAL FUSE
THERMOSTAT
TERMINAL BLOCK
THERMOSTAT BULB
GROMET
CABLE