2.5 DO NOT operate the appliance if:
1. Water ceases to ow during use.
2. Water has entered inside the unit because of an incorrectly tted cover.
3. If the appliance is damaged.
(in all cases turn off mains power and isolate water supply)
2.6 ISOLATE the electrical and water supplies before removing the cover.
2.7 ISOLATE the electrical and water supplies BEFORE proceeding with
installation or servicing.
2.8 The product is NOT SUITABLE for mounting into steam rooms or
steam cubicles.
2.9 The installation must be carried out in accordance with the relevant
requirements of:
• The appropriate Building Regulations either The Building Regulations,
The Building Regulations (Scotland) or Building Regulations (Northern
Ireland).
• The Water Fittings Regulations or Water Byelaws in Scotland.
• The IEE Wiring Regulations - BS7671.
CAUTION
2.10 It is recommended that persons who may have difculty understanding or
operating the controls should not be left unattended whilst using the appliance.
Special consideration should be given to young children and persons with
reduced physical, sensory or mental capabilities.
2.11 Only use designated entry points for cable and pipe.
PLUMBING
2.12 The plumbing installation must comply with Water Regulations.
2.13 The supply pipe must be ushed to clear debris.
2.14 DO NOT solder pipes or ttings within 300mm of the heater once the pipe
work is located in the appliance, as heat transfer can damage components.
2.15 All plumbing connections must be completed and checked for leaks before
making the electrical connections.
ELECTRICAL
2.16 Before tting the appliance, ensure that the consumer unit and any
switches are suitable for the additional load. If in doubt, contact your electricity supplier or a qualied
electrician.
2.17 The installation must comply with the latest BS 7671 ‘Requirements for
Electrical Installations’ (IEE Wiring Regulations).
2.18 This appliance must be earthed.
2.19 A residual current device (rcd), formerly known as an earth leakage circuit
breaker (elcb), with a tripping current of 30mA must be incorporated in the circuit.
IMPORTANT INFORMATION
2.1 Products manufactured by Santon are to British and European Standards.
These appliances are safe and without risk, provided they are installed, used
and maintained in good working order in accordance with our instructions and recommendations.
2.2 Please read and understand these instructions before starting work
and retain them for later use.
2.3 DO NOT operate the appliance if it is frozen, or suspected of being
frozen. See Fault Finding table (section 7.0).
2.4 These heaters are of the closed outlet type (unvented pressure system) and
are suitable for connection to normal cold water mains supplies up to a
maximum of 0.7MPa (7.0bar) for 7/9kW and12kW
2.0 SAFETY