– 3 –
In-ceiling Mount (Closed Type)
Make sure to also consult the In-ceiling Bracket Closed Type Instruction Manual.
1Draw a circumference on the ceiling using the
supplied drop-prevention cable (A) as compass, and
drill a hole for installing the in-ceiling bracket.
●Pull out the cables from the ceiling.
2Pass the supplied screws aand washer bthrough
each of the power board unit screw holes (B) and
fasten them loosely using washers (4 places).
3Align the arrows (C) of the same color (blue) on the
power board unit and the in-ceiling bracket, and
mount the power board unit. Tighten firmly the
screws (B) loosely fastened in the previous step.
●Pass the video cable (D) through the bracket cable
hole as preparation for the next step.
4Attach the supplied safety wire (E) to the ceiling
beam, for example, then connect it to the
bracket-top hook (F).
5Connect the video cable and pass the connection
cables through the bracket.
6Insert the bracket into the ceiling hole and fix it
using screws (G) (2 places).
7Connect the cables and set the switches.
☞See “Connections and Settings” on page 5.
8Align the arrows (C) of the same color (blue) on the
camera unit and the inner side of the bracket, and
push the camera unit until they click.
9Align the SANYO logos on the supplied bracket
cover and the bracket, and push the cover until they
click.
■How to attach the drop-prevention cable
(accessory)
Fasten the drop-prevention cable (A) to the hooks (H) on
the bracket and its cover, then slide the cable as shown in
the figure.
■To remove the camera unit
1. Installing the power board unit
2. Installing on the ceiling
H
AH
B
5
44
6
A
a
b
E
G
G
D
F
FE
GG
2
B
B
B
7
9
6
3C; Blue
C; Blue 8
φ192 mm/7.6”
VA-80ME
Bracket coverSafety wireScrew a, washer b
(for power board unit)
Drop-prevention
cable
Accessories
L5BU2_XE(INSTALLATION).book 3 ページ 2007年8月1日 水曜日 午前11時7分