3 SZW-02 SATEL
Entering an invalid code is indicated by two beeps. After an invalid code is entered three times,
the ALM output will turn on. The ALM output will be turned off when the valid code is entered.
3.3 Controlling the relay output
Enter the code and press . The output will be turned on for a preset time (monostable mode) or
switched (bistable mode).
3.4 Changing the user code
1. Enter the code and press . The red and green LEDs will start flashing.
2. Enter the new code (from 1 to 12 digits) and press . The change of code will be confirmed by
four short and one long beep.
A secure code should contain at least 4 digits.
3.5 Service mode
Starting the service mode from keypad
1. Enter the service code.
2. Press .
Starting the service mode from pins
1. Power down the code lock.
2. Put a jumper on the RESET pins.
3. Power on the code lock.
4. Remove the jumper from the RESET pins.
Starting the service mode will be confirmed by four short and one long beep. When the lock operates
in the service mode, the green and red LEDs are flashing alternately and short intermittent beeps are
generated.
Service functions
Starting of a function is confirmed by three short beeps. Exiting the function after confirmation of
changes is indicated by four short and one long beep.
If no key is pressed for 45 seconds after the function was called, the lock will exit the function without
saving the changes.
Pressing will exit the function without saving the changes.
exit service mode
change service code –after the function is started, the red LED will be flashing
rapidly. Enter the new code (1...12 digits) and press .
relay output operating mode –after the function is started, the LED indicating the
current configuration will go on (green –bistable mode; red –monostable mode).
Change the configuration by pressing:
–bistable mode;
–monostable mode.
Press to confirm changes.
relay output type –after the function is started, the LED indicating the current
configuration will go on (green –NO; red –NC). Change the configuration by pressing:
–NO (contacts open);
–NC (contacts closed).