The SZW-02 code lock is designed to control the alarm system, electric strike, electromagnetic lock or
another device.
Fig. 1: SZW-02 code lock with open and closed flip cover.
1 Features
Relay output for control of devices with current consumption up to 2 A.
–output type: NO or NC,
–operating mode: bistable or monostable.
ALM output (OC type) turned on when an invalid code is entered three times.
Ability to change the code by the user.
LED indicators.
Control input for the LED.
12 keys with backlighting.
Built-in piezoelectric transducer for acoustic signaling.
Tamper protection against enclosure opening and removal from the wall.
2 Installation
The lock should be installed by qualified personnel.
Disconnect power before making any electrical connections.
The code lock is designed for indoor installation. The place of installation should be readily accessible
to the users.
1. Place the enclosure base on the wall and mark the location of mounting holes.
2. Drill the holes for wall plugs (anchors).
3. Run the wires through the opening in the enclosure base.
4. Using wall plugs (anchors) and screws, fasten the enclosure base to the wall. Select wall plugs
specifically intended for the mounting surface (different for concrete or brick wall, different for
drywall, etc.).
5. Connect the wires for device control to the C terminals (relay output).
6. You can connect the ALM terminals to the alarm control panel zone.
7. You can connect the TMP terminals to the alarm control panel zone.

SATEL SZW-02 2
8. Connect the power wires to the +12V and GND terminals.
9. Close the enclosure.
10. Turn the power on.
Fig. 2. Example of connecting the actuator to the code lock.
2.1 Terminals
GND –common ground
C –relay output
+12V –power input
TMP –tamper output (NC)
ALM –output indicating that invalid code has been entered three times (OC type output –
shorted to common ground when active)
+LD, -LD –control input for the SYSTEM LED
3 Using
3.1 LED indicators
LED
Color
Description
SYSTEM
yellow
function determined by the installer
ON
red
relay output turned on
OFF
green
relay output turned off
3.2 Code
In order to be able to use the lock, enter the code on the numerical keypad.
By factory default, the following codes are programmed in the code lock:
service code: 12345
user code: 1234
Change the factory default codes before you start using the code lock.
Do not make your code available to other people.

3 SZW-02 SATEL
Entering an invalid code is indicated by two beeps. After an invalid code is entered three times,
the ALM output will turn on. The ALM output will be turned off when the valid code is entered.
3.3 Controlling the relay output
Enter the code and press . The output will be turned on for a preset time (monostable mode) or
switched (bistable mode).
3.4 Changing the user code
1. Enter the code and press . The red and green LEDs will start flashing.
2. Enter the new code (from 1 to 12 digits) and press . The change of code will be confirmed by
four short and one long beep.
A secure code should contain at least 4 digits.
3.5 Service mode
Starting the service mode from keypad
1. Enter the service code.
2. Press .
Starting the service mode from pins
1. Power down the code lock.
2. Put a jumper on the RESET pins.
3. Power on the code lock.
4. Remove the jumper from the RESET pins.
Starting the service mode will be confirmed by four short and one long beep. When the lock operates
in the service mode, the green and red LEDs are flashing alternately and short intermittent beeps are
generated.
Service functions
Starting of a function is confirmed by three short beeps. Exiting the function after confirmation of
changes is indicated by four short and one long beep.
If no key is pressed for 45 seconds after the function was called, the lock will exit the function without
saving the changes.
Pressing will exit the function without saving the changes.
exit service mode
change service code –after the function is started, the red LED will be flashing
rapidly. Enter the new code (1...12 digits) and press .
relay output operating mode –after the function is started, the LED indicating the
current configuration will go on (green –bistable mode; red –monostable mode).
Change the configuration by pressing:
–bistable mode;
–monostable mode.
Press to confirm changes.
relay output type –after the function is started, the LED indicating the current
configuration will go on (green –NO; red –NC). Change the configuration by pressing:
–NO (contacts open);
–NC (contacts closed).

SATEL SZW-02 4
Press to confirm changes.
operating time in monostable mode –after the function is started, the green LED will
be flashing rapidly. Use the keypad to enter the length of time for which the relay output
is to remain in the monostable mode (1...999 seconds). Press to confirm
changes.
keypad backlighting mode –after the function is started, press:
–always off;
–automatically on (after pressing any key);
–always on.
Press to confirm changes.
restore default settings
4 Factory default settings
Factory default codes:
user: 1234,
service: 12345.
Relay output operating mode: monostable.
Relay output type: NO.
Operating time in monostable mode: 5 seconds.
Keypad backlighting mode: automatic.
5 Specifications
Supply voltage....................................................................................................................... 9…16 VDC
Standby current consumption........................................................................................................18 mA
Maximum current consumption .....................................................................................................58 mA
ALM output (OC type).....................................................................................................30 mA / 12 VDC
Relay output ........................................................................................................................2 A / 28 VDC
Weight .............................................................................................................................................156 g
The declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o. •ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Table of contents
Other Satel Lock manuals