manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. schmersal
  6. •
  7. Switch
  8. •
  9. schmersal TQ 700 S User manual

schmersal TQ 700 S User manual

Other schmersal Switch manuals

schmersal AZM150 User manual

schmersal

schmersal AZM150 User manual

schmersal AZ 415-33ZPDK User manual

schmersal

schmersal AZ 415-33ZPDK User manual

schmersal ZQ 700-11 User manual

schmersal

schmersal ZQ 700-11 User manual

schmersal AZM400Z-ST-I2-1P2P-BOW User manual

schmersal

schmersal AZM400Z-ST-I2-1P2P-BOW User manual

schmersal AZM300B-ST-1P2P-N User manual

schmersal

schmersal AZM300B-ST-1P2P-N User manual

schmersal AZM300B-I2-ST-SD2P User manual

schmersal

schmersal AZM300B-I2-ST-SD2P User manual

schmersal TZG User manual

schmersal

schmersal TZG User manual

schmersal ZQ 700 AS User manual

schmersal

schmersal ZQ 700 AS User manual

schmersal TZG User manual

schmersal

schmersal TZG User manual

schmersal AZM300B-I2-ST-SD2P-A User manual

schmersal

schmersal AZM300B-I2-ST-SD2P-A User manual

schmersal TESF series User manual

schmersal

schmersal TESF series User manual

schmersal TV8S 521 User manual

schmersal

schmersal TV8S 521 User manual

schmersal IFL 333 Installation manual

schmersal

schmersal IFL 333 Installation manual

schmersal SHGV User manual

schmersal

schmersal SHGV User manual

schmersal AZ201ST2-T-1P2P-DU User manual

schmersal

schmersal AZ201ST2-T-1P2P-DU User manual

schmersal ZSD1 User manual

schmersal

schmersal ZSD1 User manual

schmersal T3Z 068 User manual

schmersal

schmersal T3Z 068 User manual

schmersal EX-AZM 161 User manual

schmersal

schmersal EX-AZM 161 User manual

schmersal AZM201Z-ST-T-1P2PW-2965-1 Service manual

schmersal

schmersal AZM201Z-ST-T-1P2PW-2965-1 Service manual

schmersal BN 325-R User manual

schmersal

schmersal BN 325-R User manual

schmersal AZM201Z-I2-CC-T-1P2PW-A Operation and maintenance manual

schmersal

schmersal AZM201Z-I2-CC-T-1P2PW-A Operation and maintenance manual

schmersal AZM 161 Series User manual

schmersal

schmersal AZM 161 Series User manual

schmersal AZ 200 T User manual

schmersal

schmersal AZ 200 T User manual

schmersal AZM300B-ST-SD2P-T Operation and maintenance manual

schmersal

schmersal AZM300B-ST-SD2P-T Operation and maintenance manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
TQ 700 S
Operating instructions
Pull-wire switches
EN
1. About this document
1.1 Function
This operating instructions manual provides all the information required
for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The product must be exclusively used in accordance with the versions
listed below or for the applications authorised by the manufacturer.
Detailed information regarding the range of applications can be found in
the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of
the component, personal hazards or damage to machinery or
plant components cannot be excluded.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................1
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Destination and use .....................................2
2.4 Technical data .........................................2
3 Mounting
3.1 General mounting instructions .............................2
3.2 Assembly layout........................................2
3.3 Dimensions ...........................................3
4 Electrical connection
4.1 General information for electrical connection..................3
4.2 Contact variants........................................3
4.3 Switch travel diagrams...................................3
5 Set-up and maintenance
5.1 Functional testing.......................................3
5.2 Maintenance ..........................................3
6 Disassembly and disposal
6.1 Disassembly...........................................3
6.2 Disposal ..............................................3
7 EU Declaration of conformity
01.2017 / 574454-EN / F
EN Operating instructions. . . . . . . . . . . . .pages 1 to 4
Original
2
Operating instructions
Pull-wire switches TQ 700 S
EN
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
kTQ 700-
➀
S-
➁
-
➂
No. Option Description
➀
11 1 NO/1 NC contacts
20 2 NO contacts
02 2 NC contacts
➁
Traction force 88 N
40N Traction force 40 N
➂
cable entry M20
ST Connector plug M12 (A-coding)
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Destination and use
Pull-wire switches are used to give signals to start machines and to
open or close electrically-driven doors and gates. If the pull-wire is
pulled, the switching function of the pull-wire switch is activated.
2.4 Technical data
Standards: IEC 60947-5-1
Enclosure: thermoplastic
Cover: thermoplastic
Protection class: IP67 to IEC 60529
Protection rating: II,
X
Degree of pollution: 3
Contact material: Silver
Switching system: slow action with double break,
NC contact with positive break
A
Connection: screw terminal, connector plug M12
Cable section: 2.5 mm² (incl. conductor ferrules)
Cable entry: 1 x M20 x 1.5
Rated impulse withstand voltage Uimp:
- screw terminal: 6 kV
- connector plug M12: 0.8 kV
Rated insulation voltage Ui:
- screw terminal: 500 V
- connector plug M12: 50 V
Thermal test current Ithe:10 A
Rated operating current/voltage Ie/Ue:4 A / 230 VAC,
4 A / 24 VDC
Utilisation category: AC-15, DC-13
Required short-circuit current: 1000 A
Max. fuse rating: 6 A gG D-fuse (IEC 60269-1)
Ambient temperature: –25 °C … +70 °C
Relative humidity: 30 … 95%,
no condensation,
no icing
Mechanical life: >1 million operations
Traction force F: 88 N (± 15 %)
- version TQ 700-..S-40N: 40 N (± 15%)
AWG 14, Solid/Stranded. Max. torque: 7 in. lb.
Use copper conductors only.
3. Mounting
3.1 General mounting instructions
The installation may only be carried out by authorised personnel.
The pull-wire switch is fitted by means of four screws (distance of the
drill holes 30 mm or 60 mm).
3.2 Assembly layout
The pull-wire switch must be fitted vertically. (Pull wire with ball
available as accessory.)
Traction force F
3
TQ 700 S
Operating instructions
Pull-wire switches
EN
3.3 Dimensions
All measurements in mm.
TQ 700 S
2
60
160
17
30,5
40,5
42,2
30
40,5
p/M5
M20x1,5
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised
personnel in a de-energised condition.
1. Cover screws must be loosened
2. Dust shield cap remove
3. Cable glands M20 x 1.5 with an appropriate degree of protection
must be used
4. When wiring, please ensure that no cables are located within the
range of the lever system
5. The inside of the switch must be imperatively cleaned (e.g. removal
of cable residues), considering that foreign bodies can affect the
switching behaviour
6. The cover screws must be tightened uniformly (tightening torque 0.5 Nm)
Accessories cable gland:
Ordering code: 103006013
Authorised cable diameter: 6 - 12 mm
Tightening torque: 4.5 Nm
4.2 Contact variants
The symbols are shown for the switch in non-actuated condition.
TQ 700-11S TQ 700-02S TQ 700-20S
14
13
22
21
12
11
22
21
14
13
24
23
Connector
TQ 700-11S-...-ST TQ 700-02S-...-ST TQ 700-20S-...-ST
12
34
21
13
22
14
12
34
21
11
22
12
12
34
23
13
24
14
Key
A
Positive break NC contact
4.3 Switch travel diagrams
TQ 700-11S TQ 700-02S
04
33,7
5
13-14
21-22
0
33,7
5
11-12
21-22
TQ 700-20S
045
13-14
23-24
TQ 700-11S-40N TQ 700-02S-40N
03
2
5
13-14
21-22
0
2
5
11-12
21-22
TQ 700-20S-40N
035
13-14
23-24
5. Set-up and maintenance
5.1 Functional testing
The function of the component must be tested. The following conditions
must be previously checked and met:
1. Correct fixing of the pull-wire switch
2. Check the integrity of the cable entry and connections
3. Check the switch enclosure for damage
4. Check the functionality of the switch by actuating the wire
5.2 Maintenance
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check the functionality of the switch by actuating the wire
2. Check the cable entries and the wire connections
3. Remove particles of dust and soiling
Do not open the device when live.
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The switch must be disassembled in a de-energised condition only.
6.2 Disposal
The switch must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
4EN
TQ700S-F-EN
Operating instructions
Pull-wire switches TQ 700 S
7. EU Declaration of conformity
Place and date of issue: Boituva, 11. Januar 2017
Authorised signature
Marco Antonio De Dato
Head of Engineering and Design
EU Declaration of conformity
Original ACE Schmersal
Eletroeletrônica Industrial Ltda.
Av. Brasil, nº 815
Jardim Esplanada
CEP: 18550-000 Boituva – SP
Brazil
Internet: www.schmersal.com.br
We hereby certify that the hereafter described components both in their basic design and construction conform
to the applicable European Directives.
Name of the component: TQ 700 S
Type: See ordering code
Description of the component: Pull-wire switches
Relevant Directives: Low Voltage Directive
RoHS-Directive
2014/35/EU
2011/65/EU
Applied standards: DIN EN 60947-5-1:2010
Person authorised for the compilation
of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone +49 - (0)2 02 - 64 74 - 0
Telefax: +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com
Production site:
ACE Schmersal
Eletroeletrônica Industrial Ltda.
Av. Brasil, nº 815
Jardim Esplanada – CEP: 18550-000, Boituva – SP
Brazil
Phone +55 - (0)15 - 32 63 - 9866
Fax +55 - (0)15 - 32 63 - 9890
E-Mail: [email protected]
Internet: http://www.schmersal.com.br