1. Wiring for 4796
25
7
7
30
7
25
Cable guard
Cable Clamp
N blue
Yellow / green
L brown
Torque Value
0.8Nm
Torque Value
0.4Nm
Torque Value
0.4Nm
4796-01XX:
cut for cables
over Ø 8.5 mm
Cable end sleeves
(Optional, not enclosed)
Applicable Cable Types
IEC
Type
Cable Type1)
WireSize
Cable Ø
min.2)
max.
max.
4796
H05VV -F 3G
3x 1.00mm2
3x 1.50mm2
10.4mm
H05RR-F 3G
3x 1.00mm2
3x 1.50mm2
10.4mm
UL
Type
Cable Type3)
WireSize
Cable Ø
min.
max.
max.
4796
SV…
3x AWG16
3x AWG16
10.4mm
SJ…
3x AWG16
3x AWG14
10.4mm
1) Harmonized w ire codinginaccordance withIEC60227-5 respectively IEC60245-4.
2) If cordhas a length exceeding2m, nominal cross-sectionalareas shallbe1.0mm2or more.
3) Types according to UL 62 w hich begins with the given letters (i.e. SV… includes SV, SVT, SVE etc.).
1. Wiring for 4796
25
7
7
30
7
25
Cable guard
Cable Clamp
N blue
Yellow / green
L brown
Torque Value
0.8Nm
Torque Value
0.4Nm
Torque Value
0.4Nm
4796-01XX:
cut for cables
over Ø 8.5 mm
Cable end sleeves
(Optional, not enclosed)
Applicable Cable Types
IEC
Type
Cable Type1)
WireSize
Cable Ø
min.2)
max.
max.
4796
H05VV -F 3G
3x 1.00mm2
3x 1.50mm2
10.4mm
H05RR-F 3G
3x 1.00mm2
3x 1.50mm2
10.4mm
UL
Type
Cable Type3)
WireSize
Cable Ø
min.
max.
max.
4796
SV…
3x AWG16
3x AWG16
10.4mm
SJ…
3x AWG16
3x AWG14
10.4mm
1) Harmonized w irecodinginaccordance withIEC60227-5 respectively IEC60245-4.
2) If cordhas a length exceeding2m, nominal cross-sectionalareas shallbe1.0mm2or more.
3) Types according to UL 62 w hich begins with the given letters (i.e. SV… includes SV, SVT, SVE etc.).
owner
vettersa creation date
22.10.2019 release date
22.10.2019 released by
vettersa change order no
2018605 rev
Gpage
1 of 2 0115.0049
Operation Manual Wiring for 4796
2. Assembly Instruction
Disconnect power before wiring.
Keep removed piece parts at a safe place to have them ready for reassembling.
1. Loosen cover screw and remove cover.
2. Loosen cable clamp screws and remove cable guard.
3. Insert cord into PVC-cable guard.
4. Remove outer jacket on cord ca. 25 mm. Make sure not to hurt insulation of single conductors.
5. Strip bare each copper conductor 7 mm and crimp on multicore cable ends. Do not strip more than 7 mm.
6. Loosen terminal screws but do not remove screws.
For connecting wires to terminals insert bare ends of conductors from left side of terminal screw according to figure
below. Make sure that no copper strands splice off when connecting conductors to clamps.
correct wrong
P O
7. Connect green or green/yellow (ground) wire to center clamp marked with ground symbol.
8. Connect blue (white or light grey) wire to clamp marked „N“ (neutral).
9. Connect brown (black / “hot”) wire to clamp marked „L“ (line).
10. Tighten all wire clamp screws with a torque of 0,8 Nm.
11. Insert shoulder of PVC-cable guard into cutout of base unit.
12. Assemble cable clamp over cut-off end of outer jacket of the cord and tighten cable clamp screws with a
torque of 0,4 Nm.
13. Assemble cover unit and tighten cover screw with a torque of 0,4 Nm.
Warning: Failure to wire as instructed may cause personal injury or damage to device or equipment.
To be installed or checked by an qualified person only.
For factory assembly only.
2. Assembly Instruction
Disconnect power before wiring.
Keep removed piece parts at a safe place to have them ready for reassembling.
1. Loosen cover screw and remove cover.
2. Loosen cable clamp screws and remove cable guard.
3. Insert cord into PVC-cable guard.
4. Remove outer jacket on cord ca. 25 mm. Make sure not to hurt insulation of single conductors.
5. Strip bare each copper conductor 7 mm and crimp on multicore cable ends. Do not strip more than 7 mm.
6. Loosen terminal screws but do not remove screws.
For connecting wires to terminals insert bare ends of conductors from left side of terminal screw according to figure
below. Make sure that no copper strands splice off when connecting conductors to clamps.
correct wrong
P O
7. Connect green or green/yellow (ground) wire to center clamp marked with ground symbol.
8. Connect blue (white or light grey) wire to clamp marked „N“ (neutral).
9. Connect brown (black / “hot”) wire to clamp marked „L“ (line).
10. Tighten all wire clamp screws with a torque of 0,8 Nm.
11. Insert shoulder of PVC-cable guard into cutout of base unit.
12. Assemble cable clamp over cut-off end of outer jacket of the cord and tighten cable clamp screws with a
torque of 0,4 Nm.
13. Assemble cover unit and tighten cover screw with a torque of 0,4 Nm.
Warning: Failure to wire as instructed may cause personal injury or damage to device or equipment.
To be installed or checked by an qualified person only.
For factory assembly only.
owner
vettersa creation date
22.10.2019 release date
22.10.2019 released by
vettersa change order no
2018605 rev
Gpage
2 of 2 0115.0049
Operation Manual Wiring for 4796

Other SCHURTER Cables And Connectors manuals

SCHURTER 4762 Series User manual

SCHURTER

SCHURTER 4762 Series User manual

SCHURTER 4710-5 User guide

SCHURTER

SCHURTER 4710-5 User guide

SCHURTER 4795 Series User manual

SCHURTER

SCHURTER 4795 Series User manual

SCHURTER 9009 User manual

SCHURTER

SCHURTER 9009 User manual

SCHURTER 4790 Series User manual

SCHURTER

SCHURTER 4790 Series User manual

SCHURTER DS11 User manual

SCHURTER

SCHURTER DS11 User manual

SCHURTER 0104U Series User manual

SCHURTER

SCHURTER 0104U Series User manual

SCHURTER 4781 User manual

SCHURTER

SCHURTER 4781 User manual

SCHURTER 4783 Series User manual

SCHURTER

SCHURTER 4783 Series User manual

Popular Cables And Connectors manuals by other brands

OUNEVA VC02-0004 installation guide

OUNEVA

OUNEVA VC02-0004 installation guide

Sony PS VITA PCH-ZUC1 instruction manual

Sony

Sony PS VITA PCH-ZUC1 instruction manual

Techno TH387 Assembly instructions

Techno

Techno TH387 Assembly instructions

Alcad SCM-051 manual

Alcad

Alcad SCM-051 manual

HRS ZE05 Series instruction sheet

HRS

HRS ZE05 Series instruction sheet

NEUTRIK FIBERFOX NO4M4DW-FX Handling instruction

NEUTRIK

NEUTRIK FIBERFOX NO4M4DW-FX Handling instruction

Hubbell 228FTV Installation & operating instructions

Hubbell

Hubbell 228FTV Installation & operating instructions

Bogen CK10 installation guide

Bogen

Bogen CK10 installation guide

ROSE DISPLAYS CABLE AND CRIMP SLEEVES instruction sheet

ROSE DISPLAYS

ROSE DISPLAYS CABLE AND CRIMP SLEEVES instruction sheet

Philips SWV2023NB Specifications

Philips

Philips SWV2023NB Specifications

Crestron FlipTop CBLR2 Series Do guide

Crestron

Crestron FlipTop CBLR2 Series Do guide

Philips SDW1400GN Specifications

Philips

Philips SDW1400GN Specifications

Alemite 7342 Service guide

Alemite

Alemite 7342 Service guide

CYP CLUX-14E Operation manual

CYP

CYP CLUX-14E Operation manual

Philips SWA2704W Specifications

Philips

Philips SWA2704W Specifications

Ace Plus EX-G048D user manual

Ace Plus

Ace Plus EX-G048D user manual

Hive Plug user guide

Hive

Hive Plug user guide

Radiall SOLYNEO CO15CAN product manual

Radiall

Radiall SOLYNEO CO15CAN product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.