INSTALLATION INSTRUCTIONS
S6000DE / S6000KDE DELAYED EGRESS DEVICE
Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display
Stop Employee Theft
Stop Retail Shoplifting
Restrict Airport Patrons
Restrict Wandering Patients
The integral verbal message, digital countdown display and sign
provide comprehensive and clear instructions of the door operation
for persons without prior knowledge of the exit delay, including the
sight and hearing impaired.
The digital keypad eliminates the need to carry and locate keys for
reset and bypass functions.
Features:
Egress Delay
15 or 30 second exit delay
1 or 2 second nuisance delay
Built-In 3 Function keypad
Alarm and lock reset
1 to 30 second bypass
Sustained bypass
Additional keyswitch optional
Control Inputs
1 to 30 second request-to-exit and bypass
input with anti-tailgate and jumper
selectable door prop alarm.
Reset
Built-In Annunciation
Armed mode
Nuisance mode
Irreversible egress mode
Release mode
Digital countdown mode
Field selectable voice notification or tone
Field selectable male voice with security
message or female voice with safety
message
Monitoring Outputs
Armed mode
Egress initiation status
Released status
Trigger Modes
Egress alarm triggered by Push Bar
Trigger input from external device field
selectable (N/O or N/C)
Code Compliance
IFC International fire Code
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1 Uniform Fire Code
California Building Code
Field selectable automatic or manual power up after emergency release or power loss.
Use of manual power up complies with California Building Code (OSHPD) requirements.
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Application:
When unauthorized egress is initiated SDC
exit Check delays egress through the door
for 15 seconds (or 30 seconds). Meanwhile,
the person exiting must wait while personnel
or security responds. The door unlocks after
15 seconds have elapsed permitting egress.
When powered by a fire control supervised
power supply, the lock will release
immediately in an emergency.
R
Choice of Mounting
Recessed mounted
(3 gang metal plaster ring included)
Surface mounted with optional 3 gang
box (DEC-J)
Optional shroud (SHD-J) to be used with
DEC-J surface box.
S6000DE
MODELS
S6000KDE
RIM MOUNT
VERTICAL ROD
MORTISE
EXIT DEVICES
NOTE: SDC 600 Series Power Supply required

SURFACE MOUNT 3 GANG BOX OVER
EXISTING RECESSED 2 GANG BOX
2) Carefully insert unit and
secure with screws
supplied.
1) Attach optional 3 Gang Surface
Mount Box to existing recessed 2 gang
box using screws supplied.
RECESSED MOUNTING
DRY WALL
KEY CYLINDER INSTALLATION
WITH KEY CYLINDER IN PROPER
POSITION INSIDE SWITCH BLOCK,
TIGHTEN THE SET SCREW TO
LOCK CYLINDER IN PLACE.
1-1/8” KEY CYLINDER
7185SC1-26D-KD
1-1/4” KEY CYLINDER
REQUIRES COLLAR
3-3/4"
1) Cut hole in dry wall to
dimensions shown.
2) Mount wall bracket
over hole.
3) Carefully insert unit and
secure with screws
supplied.
5-3/4”
PTH-4 = Power Transfer Hinge
PTH-4DPS = Power Transfer Hinge w/DPS
*
PU
SH
UN
T
I
L
AL
AR
M
SO
UN
D
S.
D
OOR
C
A
N
BE
OP
EN
ED
I
N
1
5
SEC
ON
D
S.
*PTH-4
Power Supply
602RF
PU
S
H
U
NT
I
L
A
LAR
M
S
OU
ND
S.
D
OOR
CA
N
B
E O
PEN
ED
IN
15
SE
C
OND
S
.
Power Supply
602RF
*PTH-4
6 Wires
4 Wires
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 2

RECOMMENDED MOUNTING
PROCEDURE
WIRE UNIT AS SHOWN
(SHOWN WITH NO OPTIONS).
SLIDE PACKING FOAM BETWEEN WALL
AND UNIT TO PREVENT DAMAGE TO FACEPLATE
USE 1-1/4” SCREWS SUPPLIED WITH
WALL MOUNT FRAME TO HANG UNIT
TEMPORARILY FOR WIRING PURPOSES
W
H
T
W
H
T
R
E
D
B
L
K
TO
PANIC DEVICE FROM
POWER SUPPLY
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 3

WARNING!
CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL
PRIOR TO SELECTING DELAY TIME OR PWR-UP SETTINGS
101-DE
101-KDE
PWR LOCK RED R
NO C
TRIG REX RESET
C NOC NOC NO-+-+
To
Power
Supply
TANDEM UNIT
(PAIR OF DOORS)
WHT
WHT
BLK
RED
WHT
WHT
BLK
RED
POWER
TRANSFER
HINGE
POWER
TRANSFER
HINGE
DPS
DPS
SDC 600 Series Power Supply required
**
DIP SWITCH
SETTINGS
15 30
12
15 20 30 1
N/CN/O
UNLOCKED LOCKED
VOICE/TONE
TONE
ONLY
FEMALE
MSG
MALE
MSG
ON
DELAY
TIME
[ON]
[OFF]
12345678
NUISANCE
DELAY
REX/BYPASS
PERIOD
TRIGGER
TYPE
PWR UP
STATE
ALARM
TYPE
MESSAGE
JUMPER J1**
24VDC @ 430mA (Single)
@ 680mA (Tandem)
Monitor Relays
Contact Rating
Operating Temp
Range
Power
Requirements
SPDT (Dry)
1 Amp @12/24VDC (Resistive)
0 C to 70 C
Note:
**JUMPER J1 (DOOR PROP)
INSTALLED: The S6000DE/KDE will enter the alarm mode if the
door is held open past the request to exit period.
REMOVED: The S6000DE/KDE will remain unlocked if the door
is held open past the request to exit period. No alarm will sound.
For the S6000DE/KDE to relock and rearm upon closure of the
door, DPS is required.
Door Contact or Power Transfer Hinge by DPS required for Anti-
Tailgate and Door Prop operation.
**
**
To
Power
Supply
101-DE / 101-KDE
PWR LOCK RED ONLY
NO C
TRIG REX RESET
C NOC NOC NO
-+-+
GRN ONLY
WHT
WHT
BLK
RED
POWER
TRANSFER
HINGE
SINGLE
DOOR
DPS
**
}
}
Alarm Secure
}
}
Remote
Access
Remote
Reset
Monitor Relays
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 4

Keypad Programming
KEYPAD STATUS LEDS
YELLOW For ADA requirements, it will light
each time a key is pressed
Flash :
GREEN Power on, No errors,
No outputs are active
Slow :
Flash
Fast :
Flash
Steady :
No errors,
At least one output is active
Keypad is in Programming Mode
RED General error, invalid code
entered
Slow :
Flash
Steady :
Error condition
At least one output is active
FACTORY PROGRAMMED CODES
1234 Master Code (default)
11 Reset
22 Authorized Exit (Rex)
Function
Pin
Code
33 Bypass (toggle on/off)
User
No.
1
2
3
4
Output
Code
NA
1
2
3
*
*
*
*
If the factory programmed codes are acceptable for your
installation, no additional programming is required.
System Operation
The door is unlocked until the REX
timer has expired or until the door
has been opened and then closed.
AUTHORIZED EGRESS [REX] (Green LED Solid)
Door Closed
--
--
--
-- Door has
been opened
Keypad Code 22*
The door is still locked and secure. The display is counting
down with audible alarm/voice instructions. Once the display
reaches “00”, the door will unlock.
15 14 01
DELAYED EGRESS MODE
RESET [Armed] (Green LED solid) Keypad Code 11*
The door is locked
and secure
15 30
or
--
POWER-UP LOCKED
The door is
locked and
secure
15 30
or
POWER-UP UNLOCKED
The door is unlocked. To enter the
Armed Mode, turn the keyswitch to
Reset or enter the Reset Code
“11 ” on the keypad
*
00 00 The door is unlocked and
has been opened
ALARMED UNLOCKED [Alternating Display]
--
--
--
The door is unlocked and the alarm
is sounding. To return to Armed
Mode, close the door and turn the key
to Reset or enter the Reset Code “11 “
on the keypad
*
BYPASS [Extended Unlock] (Green LED Flashing)
Door Closed
--
--
--
-- Door has
been opened
Keypad Code 33*
The door is unlocked indefinitely. To return to
Armed Mode, turn the keyswitch to bypass or
enter the Bypass Code “33 “on the keypad.
*
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 5

*
Deleting a User (Option 2)
To add a user:
Press 2# User Number (2 digits)# .
For example: 2# 05# deletes user 5.
*
*
Erase All Users (Option 8)
To ERASE ALL USERS!!
Press 8# .
All users are erased and the Default Master Code is reset to 1234.
KP
RST
CNO CNO CNO
TRIG REX RESET
*
Returning the Keypad to Factory Default Settings
Short the KP RST terminal located on the main controller board.
Press 99# 1234 8# .
Press 3#1#2# . Sets the Output #1 (Reset) for 2 seconds.
Press 3#2#2# . Sets the Output #2 (Auth Exit) for 2 seconds.
Press 3#3#0# . Sets the Output #3 (Bypass) for latching.
Press 1#02#11#2# . Adds user # 2 with a code of 11. [Reset]
Press 1#03#22#3# . Adds user # 3 with a code of 22. [Auth Exit]
Press 1#04#33#4# . Adds user # 4 with a code of 33. [Bypass]
Press to exit programming mode.
Remove the shorting jumper from the KP RST terminal.
*
*
*
*
*
*
*
**
*
Entering Programming Mode
Press 99# Master Code .
For example: 99# 1234 Enters programming mode using the Default Master Code.
*
**
Exit Programming Mode
Press .
*
*
** *
*
Changing the Master Code
User 1 is always used as the Master Code and is required to access keypad programming. The Factory
Default Master Code is “1234 ”. It is strongly recommended that a new Master Code is assigned after
installation. WRITE DOWN THE NEW CODE. If the master code is lost, you must use the keypad reset jumper
on the main circuit board to enter programming mode by using the Default Master Code.
To Change the Master Code (User 1)
1) Enter Programming Mode: Press 99# Master Code .
2) Assign new Master Code : Press 1# 01# New Pin Code# Output Relay # .
For example: 99# 1234 1# 01# 3871# 0# changes the Master code from 1234 to 3871.
3) Press to exit programming mode.
*
Adding a User / Changing User Pin Codes (Option 1)
To add a user:
Press 1# User Number (2 digits)# New Pin Code# Output Relay # .
For example: 1# 05# 55# 2# adds user 5's pin code as one that will activate authorized exit.
*
Output Relay Codes
2= Reset
3= Authorized Exit
4= Bypass
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 6

User
Number Name PIN
Code
User
Number Name PIN
Code
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 7

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 8

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 9

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 10

P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 11
Other manuals for S6000DE
1
This manual suits for next models
1
Table of contents
Popular Gate Opener manuals by other brands

Chamberlain
Chamberlain RSL12U installation manual

Chamberlain
Chamberlain LiftMaster Professional HS670 user manual

SOMFY
SOMFY Dexxo RTS Pro INSTALLATION INSTRUCTIONS-ILLUSTRATIONS

Vicway
Vicway F-600 Assembling and operating manual

Centurion
Centurion D2 Turbo user guide

Aprimatic
Aprimatic AT 92 T Mechanical installation, Use and Maintenance instructions