950-0234revC - 9 - June 7, 2021
COOL mode –Unit cools room to set point temperature. Set point temperature can be set
from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures of +4 to +118 ºF in the
cooling mode. Indoor fan does not turn off in the cooling mode when temperature set point
has been satisfied. It will continue to run to keep the room temperature consistent.
•HEAT mode (for Heat Pump units only) - Unit heats room to set point temperature. Set point
temperature can be set from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures
of -5 ºF to +75 ºF in the heating mode. Indoor fan will turn off in heating mode when
temperature set point has been satisfied.
•DRY mode –Set point temperature can be set from 61°F to 86°F. Unit cools at 90% capacity
while the FAN runs in LOW speed only (FAN speed cannot be changed).
•FAN mode –Selects fan only operation. Set point temperature can be set from 61 °F to 86 °F.
Fan speed can be set to AUTO, HIGH, MEDIUM or LOW.
SLEEP –In the COOL mode adjust the set-point temperature to a comfortable setting, and then
press the SLEEP button. After 1 hour, the set-point will increase by 1.8 ºF (1 ºC). After 2 hours have
passed temperature is increased by 3.6 ºF (2 ºC). Temperature will never increase more than 3.6 ºF
(2 ºC) from set-point or beyond 86 ºF (30 ºC). The temperature will stay at this setting until the unit is
turned off or the SLEEP function is disabled.
In the HEAT mode adjust the set-point temperature to a comfortable setting, and then press the
SLEEP button. After 1 hour the set-point will decrease by 1.8 ºF (1 ºC). After 2 hours have passed
temperature is decreased by 3.6 ºF (2 ºC). Temperature will never decrease more than 3.6 ºF (2 ºC)
from set point or below 61 ºF (16 ºC). The temperature will stay at this setting until the unit is turned
off or the SLEEP function is disabled.
The SLEEP mode does not work in the FAN or AUTO modes and is deactivated when the unit is
turned off or power is lost. On power up, the SLEEP mode must be turned on again if needed. Press
the SLEEP mode button to toggle SLEEP mode off and return to normal operation.
FAN –Press this button to change fan speeds, AUTO, HIGH, MEDIUM or LOW, while in the
HEAT, COOL, FAN modes. When in the AUTO setting, the fan will run faster the further away from
the set point it gets. On the other hand the closer it gets to the set point the slower it will run.
CLOCK –Press the CLOCK button, the clock ICON will start to blink. It will only blink for 5
seconds. While blinking press and hold down the + or - keys to adjust the 24H time of day clock to
the correct time. You must immediately press the CLOCK button to set the time. If the CLOCK button
is not pressed within 5 seconds, the clock time will revert back to the original setting and clock will
have to be set again.
TEMP –Press this button, the icons will be cycled between , and in the remote display.
displays set temperature always. displays room temperature for a few seconds then display
set temperature. displays set temperature.
PURGE / BLOW –When in the COOL or DRY mode and the PURGE function is enabled, the
fan will continue to operate for 10 minutes after the unit is turned off. This function dries the
evaporation coil to prevent mold and mildew. The PURGE function will remain enabled in DRY and
COOL unless power is interrupted or is disabled by the button. PURGE will not work in AUTO, FAN
or HEAT modes.
TURBO –The TURBO function will only run while in the HEAT or COOL mode. TURBO
increases indoor fan speed (more than high fan speed).
+/ -Raises or Lowers the set point temperature. Holding the button down for more than 2
seconds will cause the set point to auto increment or decrement. This does not function in the AUTO
mode since the temperature set point cannot be changed.
DISPLAY –Turns the display on or off on the indoor unit. None of the lights will be illuminated
when off is selected.