TORQUE ADAPTOR DIGITAL 3/4” SQ. DRIVE
200-1000NM (147.5 - 737.5LB.FT)
MODEL NO: STW292.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! DO NOT use the digital torque adaptor if damaged or thought to be faulty.
8DO NOT apply force to the digital torque adaptor when the power is off. Always turn it on before using it, otherwise it will be damaged.
8DO NOT turn off the digital torque adaptor while torque force is being applied to it.
8DO NOT exceed the permitted maximum torque value. To do so will cause it to break.
8DO NOT subject the 3/4” connectors to any force other than a rotational one.
9Ensure that all components including all adaptors, extensions, drivers and sockets are rated to match or exceed the torque being
applied.
9Observe all equipment, system and manufacturer’s warnings, cautions and procedures when using this digital torque adaptor.
9Use the correct size socket for the xing.
8DO NOT use sockets that are worn or cracked.
9Check that the digital torque adaptor capacity matches or exceeds each application before proceeding.
9Ensure all workshop safety rules, regulations, and conditions are complied with when using this digital torque adaptor.
9Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9Keep children and unauthorised persons away from the working area.
8DO NOT press, pressure, or damage the LCD display.
8DO NOT use near strong magnetic elds.
8DO NOT subject to excessive force or shocks.
8DO NOT drop or throw the digital torque adaptor.
8DO NOT leave the digital torque adaptor in any place exposed to excessive heat, humidity or direct sunlight.
8DO NOT use organic solvents such as alcohol or thinners for cleaning.
8DO NOT submerge in water or any other liquid.
8DO NOT disassemble the digital torque adaptor.
9To ensure accurate measurement, periodic re-calibration is necessary.
9After use, clean with a soft dry cloth and store in a safe, dry, childproof location away from any heat sources.
9Avoid any dusty, damp or humid conditions.
2. INTRODUCTION
Designed for use with a standard ratchet or breaker bar. Ideal for work around the engine bay and the tightening of wheel nuts to factory
specifications. Large LCD display with LED/audible alarm indicating achieved and target torque levels. Selectable readings in Nm, lb.ft or
kg.m and accurate to ±2% of stated capacity. Memory stores up to 50 readings and features auto shut off after 70 seconds. Supplied
with test certificate and storage case.
3. SPECIFICATION
Model no .............................................................STW292.V2
Range ................................... 200-1000Nm (147.5-737.5lb.ft)
Accuracy .........................................................................±2%
Resolution ......................................................................... 0.1
Drive .......................................................................... 3/4”sq.
Units.................................................................. Nm/lb.ft/kg.m
Size (L x W)...................................................110mm x 56mm
Weight......................................................................... 0.72kg
Operating modes............................................ trace and peak
Memory space.................................................................... 50
Battery ................................................................. 2 x AA type
Battery life......................................................up to 110 hours
Operating temp ............................ -10°C~60°C/13.9~139.9°F
Storage temp ................................... -20°C~70°C/-4~157.9°F
Refer to
instruction
manual
Wear eye
protection
Original Language Version
© Jack Sealey Limited STW292.V2| Issue:1 20/08/18