Sealey STW292.V2 User manual

TORQUE ADAPTOR DIGITAL 3/4” SQ. DRIVE
200-1000NM (147.5 - 737.5LB.FT)
MODEL NO: STW292.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! DO NOT use the digital torque adaptor if damaged or thought to be faulty.
8DO NOT apply force to the digital torque adaptor when the power is off. Always turn it on before using it, otherwise it will be damaged.
8DO NOT turn off the digital torque adaptor while torque force is being applied to it.
8DO NOT exceed the permitted maximum torque value. To do so will cause it to break.
8DO NOT subject the 3/4” connectors to any force other than a rotational one.
9Ensure that all components including all adaptors, extensions, drivers and sockets are rated to match or exceed the torque being
applied.
9Observe all equipment, system and manufacturer’s warnings, cautions and procedures when using this digital torque adaptor.
9Use the correct size socket for the xing.
8DO NOT use sockets that are worn or cracked.
9Check that the digital torque adaptor capacity matches or exceeds each application before proceeding.
9Ensure all workshop safety rules, regulations, and conditions are complied with when using this digital torque adaptor.
9Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9Keep children and unauthorised persons away from the working area.
8DO NOT press, pressure, or damage the LCD display.
8DO NOT use near strong magnetic elds.
8DO NOT subject to excessive force or shocks.
8DO NOT drop or throw the digital torque adaptor.
8DO NOT leave the digital torque adaptor in any place exposed to excessive heat, humidity or direct sunlight.
8DO NOT use organic solvents such as alcohol or thinners for cleaning.
8DO NOT submerge in water or any other liquid.
8DO NOT disassemble the digital torque adaptor.
9To ensure accurate measurement, periodic re-calibration is necessary.
9After use, clean with a soft dry cloth and store in a safe, dry, childproof location away from any heat sources.
9Avoid any dusty, damp or humid conditions.
2. INTRODUCTION
Designed for use with a standard ratchet or breaker bar. Ideal for work around the engine bay and the tightening of wheel nuts to factory
specifications. Large LCD display with LED/audible alarm indicating achieved and target torque levels. Selectable readings in Nm, lb.ft or
kg.m and accurate to ±2% of stated capacity. Memory stores up to 50 readings and features auto shut off after 70 seconds. Supplied
with test certificate and storage case.
3. SPECIFICATION
Model no .............................................................STW292.V2
Range ................................... 200-1000Nm (147.5-737.5lb.ft)
Accuracy .........................................................................±2%
Resolution ......................................................................... 0.1
Drive .......................................................................... 3/4”sq.
Units.................................................................. Nm/lb.ft/kg.m
Size (L x W)...................................................110mm x 56mm
Weight......................................................................... 0.72kg
Operating modes............................................ trace and peak
Memory space.................................................................... 50
Battery ................................................................. 2 x AA type
Battery life......................................................up to 110 hours
Operating temp ............................ -10°C~60°C/13.9~139.9°F
Storage temp ................................... -20°C~70°C/-4~157.9°F
Refer to
instruction
manual
Wear eye
protection
Original Language Version
© Jack Sealey Limited STW292.V2| Issue:1 20/08/18

Original Language Version
© Jack Sealey Limited
4. OPERATION
NOTE: DO NOT press the Mem and Power buttons at the same time as this will enter calibration mode.
4.1. PREPARATION
4.1.1. Unscrew the four cross-head screws holding the rear battery cover and remove the battery cover (g.1). Install two AA batteries,
ensuring correct polarity. Ret the battery cover and ret and tighten the four cross-head screws.
NOTE: When battery power is low, a low battery icon will be displayed.
NOTE: DO NOT use the digital torque adaptor when the battery is in a low state of charge as this will affect the torque adaptor’s
accuracy.
4.2. POWER ON
4.2.1. Press the Power button once (g.2) to turn the digital torque adaptor on. The display will initially show “trACE” or “PtoP”. After 2
seconds the LCD panel will show “0.0”.
NOTE: If left unused, the digital torque adaptor will automatically turn off after 70 seconds.
4.2.2. Ascertain the correct size and type of socket for the xing to be tightened and attach it to the square drive connector (3/4”) at the base
of the adaptor.
4.2.3. Insert the required ratchet wrench/drive bar into the socket at the top of the adaptor. DO NOT use a tool that will allow you to apply
excessive force through the adaptor.
4.3. SELECTING UNIT OF MEASUREMENT
4.3.1. Press Mem and Peak/Trace buttons together (g.3) and release to select different units of torque measurement (Nm/lb.in/kg.m) in
rotation.
4.3.2. When the units are changed, the target setting will also be changed to the new unit value.
4.4. SETTING THE TARGET TORQUE VALUE
4.4.1. To increase the value, press and hold the (+) button (g.4), the target value will display for 10 seconds then the LCD will display 0.0.
4.4.2. To decrease the value, press and hold the (-) button (g.4), the target value will display for 10 seconds then the LCD will display 0.0.
NOTE: In use, when the torque is approaching within 20% of the target value, the red LED will ash and an intermittent buzzer warning
will be heard, indicating that the target torque value is nearing. When the target torque value is reached, the red LED will illuminate
and the buzzer will sound. Immediately stop applying pressure to the xing.
4.5. SELECTING PEAK OR TRACE
4.5.1. Selecting Peak:
Press and release Peak/Trace button (g.5), the LCD panel shows “PtoP“, after 2 seconds the LCD panel shows 0.0.
4.5.2. Selecting Trace:
Press and release Peak/Trace button (g.5), the LCD panel shows “trACE“, after 2 seconds the LCD panel shows 0.0.
4.6. MEMORY
4.6.1. Store reading must be under the “PtoP” mode.
4.6.2. Press “Mem” button for at least 1 second and release (g.6), the LCD display shows the memory number “P01” then the torque value
for this.
fig.1fig.2
fig.5fig.6fig.7
fig.3fig.4
STW292.V2| Issue:1 20/08/18

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
4.6.3. Pressing the “Mem” button again for at least 1 second, the LCD display shows the memory number “P02” and then the torque value.
Repeat to cycle through all memory values (“P01” is the latest reading, “P50” is the oldest). The digital torque adaptor stores the last 50
torque value readings.
4.7. TURNING ADAPTOR OFF
4.7.1. If the digital torque adaptor is not used for 70 seconds, it will automatically switch off, otherwise manually turn it off by pressing and
releasing the power button (g.7).
5. MAINTENANCE
5.1. BATTERY CARE AND USE
5.1.1. Keep the batteries dry at all times.
8DO NOT combine used batteries with new ones or mix battery types.
5.1.2. Insert/remove the batteries carefully as described in Section 4.1.1.
5.1.3. Never use a battery if it is cracked, broken or leaking.
5.1.4. Never heat or incinerate batteries.
5.1.5. See battery disposal information below.
5.1.6. If the digital torque adaptor is not being used for a longer period of time, remove the batteries to prevent damage from leakage.
5.2. CALIBRATION
5.2.1. Periodic calibration is required for this product, contact your Sealey stockist for details.
5.2.2. Use only a damp cloth for cleaning. Never use any type of liquid, aerosol cleaner, or any type of organic solvent.
Original Language Version
© Jack Sealey Limited STW292.V2| Issue:1 20/08/18
BATTERY REMOVAL REFER TO 4.1.1.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
Table of contents
Other Sealey Receiver manuals

Sealey
Sealey VS820UA.V3 User manual

Sealey