2. INTRODUCTION
Twin daylight uorescent tubes suitable for applications where mains power is unavailable. Tubes can be selected to run individually or as
a pair from rechargeable cells. Includes an integrally stored mains cable for recharging only, electronic control allows unit to be used as an
emergency light, switching on the light in the event of mains power failure. Features carry handle and oor stand, can also be wall mounted.
3. SPECIFICATION
Model No: ........................ML18/36.V3
Battery: ............................ 6V 4.5Ah
Charging Time: ...........................20hr
Operating Time: ........1 Tube; 3hr, 2 Tubes; 1.5hr
Power: .............................2 x 20W
Supply: ................................230V
Nett Weight: ........................... 1.92kg
4. OPERATION
4.1. CHARGING THE UNIT
4.1.1. The unit will charge when plugged into mains supply regardless of function switch
position. To achieve fastest charge put function switch to the ‘OFF’ position.
4.1.2. Open the power cable compartment at the back of the light. Uncoil the power
cable and plug it into the mains power supply. The red LED will light to
indicate the presence of mains power.
4.1.3. The battery pack will take approximately 20 hours to charge initially. Subsequent
charging times will depend on the state of discharge of the battery pack.
4.1.4. When charging is complete unplug the mains power cable and stow it back
in the compartment.
4.2. USING THE LIGHT
4.2.1. The function switch has three positions:- 1 Tube - OFF - Both Tubes
4.3.1. Select the required tube combination using the function switch.
4.2.2. The light will function as an emergency light if the function switch is placed in either the 1 or 2 tube position whilst connected to the mains.
In case of a mains electricity failure, the selected number of tubes will light. Restoration of mains power will switch the light off again.
4.2.3. After a full charge the light will run for approximately 1hr 30mins on two tubes and 3hrs on one tube.
NOTE! The green LED will illuminate whenever a tube should be lit. If the tubes DO NOT light and the green LED is illuminated,
suspect an unserviceable tube. The light has a TEST button feature to test the tubes. When the TEST button is pressed the
tubes should light up if connected to the mains. If any tubes fail to light up, they are likely to be unserviceable.
5. MAINTENANCE
WARNING! Before replacing the fluorescent tubes or performing any maintenance the unit must be unplugged from the mains. Allow the
tubes to cool before touching them.
WARNING! DO NOT turn the unit on with the transparent cover removed or with the tubes removed.
5.1. CHANGING THE FLUORESCENT TUBES
5.1.1. Replacement tubes must be the same type and rating as the original tubes supplied.
5.1.2. Remove the transparent cover by removing the two cover screws and lifting it away.
5.1.3. Each tube can be removed by rotating it in either direction until one of the connector pins appears at the top of the tube holder slot. Lift
out the old tube and replace it with a new one. Push the new tube all the way into the tube holder slots at both ends and then rotate
the tube a quarter of a turn in either direction.
5.1.4. Ensure that the tubes are correctly installed and seated before switching on.
5.2. CLEANING
5.2.1. Clean the unit with a damp cloth and a mild soapy solution. DO NOT use solvents or abrasive cleaners.
ML18/36.V3 | Issue 5 (HF,3) 14/05/2019
Original Language Version
© Jack Sealey Limited
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505. Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.