manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Securitron
  6. •
  7. Lock
  8. •
  9. Securitron Vista VM300 Series User manual

Securitron Vista VM300 Series User manual

Hexnut Bolt
Door Spacer
Rubber
Washer
Armature
Screw
Call 1-775-355-5625
For Technical Assistance 550 Vista Blvd., Sparks NV 89434
www.securitron.com/vista
Product Power Input Wiring:
For VM1200 and VM600 Series, this can be wired directly onto the PCB terminal
block that has label + and -.
For VM300 Series, these are ying leads. Red wire is + and black wire is -.
(NO NEED TO REMOVE COVER PLATE FOR VM300)
Wiring for models with MBS:
For VM1200 and VM600 Series, the signal is given out from SPDT relay. Wiring can
be done through PCB 3-block terminal labels NC, COM, and NO.
For VM300 series has 3 ying leads. Black wire is COM, green wire is NO and white
wire is NC.
Wiring for models with DPS:
For VM1200 Series, the signal is given out from the 3 block terminal (NC, COM,
NO) that is labeled Reed on the PCB. For VM600 Series, there are 3 ying leads.
Black wire is COM, green wire is NO and white wire is NC.
Product Specication:
• Holding Force - VM1200 Series: 1200 lbs (544 Kg)
VM600 Series: 600 lbs (272 Kg)
VM300 Series: 300 lbs (136 Kg)
• 12 & 24 volts DC operation (selectable).
Note: Factory default setting is 12VDC.
Product Type:
• Besides unmonitored version, all VM Series locks have either magnetic bond
sensor (MBS) or door position switch (DPS) or both.
• For VM1200 and VM600 Series, magnetic bond sensor uses hall effect
sensor. For VM300 Series, uses change-over reed switch sensor.
• For VM1200 and VM600 Series, door position sensing uses change-over reed
switch sensor.
VM1200 and VM600 Series with MBS:
• For VM1200 and VM600 Series, the LED operation color can be eld set. The
colors can be reversed simply by reversing the 2 pin plug connection on the PCB.
• There is no LED or DPS available on the VM300 Series
• The factory default setting is as follows:
LED indicator off (No power to the magnet)
LED indicator red (Power on magnet, door open)
LED indicator green (Power on magnet, door closed)
• Note: where the Maglock has both MBS and DPS, the LED
indicates as per the MBS model.
Product Dimensions (L x W x H):
VM1200 Series - 10-1/2” x 2-7/8” x 1-9/16” [266mm x 72mm x 40mm]
VM600 Series - 9-3/8” x 1-7/8” x 1-1/6” [238mm x 48mm x 26.5mm]
VM300 Series - 6-11/16” x 1-5/8” x 7/8” [170mm x 41.4mm x 22.8mm]
Installation Requirements:
• Adjust onboard PCB shunt settings for correct operating voltage prior to
applying power to the EML.
For 12 volts two shunts must be installed:
- First shunt joining pins 1 & 2
- Second shunt joining pins 3 & 4.
For a 24 volt system only one shunt is required, joining pins 2 & 3.
1
2
VM300, VM600 & VM1200 Series Maglock Installation Instructions
PRODUCT INFORMATION
PRODUCT INSTALLATION AND WIRING
3
STANDARD MOUNTING METHOD
• Use the supplied template
to determine the correct
location and size of
mounting holes for both
the door and frame
header. Ensure that the
door opens away from the
Maglock. In the case of a
single door, the Maglock is
positioned as close as
possible to the vertical
section of the door jamb.
• Loosely install the mounting plate using two of the supplied philips
head mounting screws in the elongated slots. Attach the Maglock to the
mounting plate.
ADJUST POSITION OF MAGNET RELATIVE TO THE ARMATURE
• Ensure the armature and magnet are aligned. Adjust the
mounting plate to suit and then drill the appropriate sized
holes in the door header for the remaining attachment screws.
• Align the armature plate on
the door using sight or the
template supplied.
• Mark and drill holes then
mount the armature to
the door. Make sure that
the armature plate is not
over tightened and that it is
installed as shown in the
following diagram. The
armature plate must be free
to self align with the door.
Mounting Plate
MOUNTING ARMATURE ON DIFFERENT DOOR TYPES
HOLLOW CORE
DOOR ENLARGE
HOLE TO 5/8in
[16mm]
SOLID CORE
DOOR ENLARGE
HOLE TO 15/32in
[12mm]
REINFORCED
DOOR
TAP 1/4-20 VM600
[M6 X 1.0]
TAP 5/16-18
VM1200
[M8 X 1.25]
Connect electrical wiring according to the local appropriate wiring rules. Make sure
the correct voltage on the PCB has been selected prior to turning on the power.
Failure to do this could damage the unit. Factory default voltage is set to 12volts DC.
Note: If a door closer has been tted then adjust it so that the armature closes
lightly against the magnet. This will avoid damage to the magnet and will also
make the door operation quieter.
The Maglock lock does not require much ongoing maintenance. The custom-
er should be advised to keep the mating faces of the armature and magnet
clean making sure that no abrasive materials are used to clean the faces.
Do not spray the magnet or armature with any
chemicals such as lacquer as the release of the Maglock may
be compromised.
6
7
MOUNTING THE ARMATURE
HOLLOW CORE
DOOR ENLARGE
HOLE TO 5/8in
[16mm]
SOLID CORE
DOOR ENLARGE
HOLE TO 15/32in
[12mm]
MOUNTING ARMATURE
ON DIFFERENT DOOR TYPES
• Ensure the armature and magnet
are aligned. Adjust the mounting plate
to suit and then drill the appropriate
sized holes in the door header for the
remaining attachment screws.
MOUNTING THE MAGLOCK MOUNTING WITH Z BRACKET KITS
Assemble Z Bracket kit as shown
MOUNTING ON GLASS DOORS ELECTRICAL CONNECTION
MAINTENANCE
VM1 Rev. C
REINFORCED
DOOR
TAP 1/4-20 VM600
[M6 X 1.25”]
TAP 5/16-18 VM1200
[M8 X 1.25]
For complete Vista Maglock
Warranty information, please visit
www.securitron.com/vista.
• Align the armature plate on the door using sight or the template supplied.
• Mark and drill holes then mount the armature to the door. Make sure that the
armature plate is not over tightened and that it is installed as shown in the
following diagram. The armature plate must be free to self align with the door.
Adjust position of
Magnet relative to
the Armature as shown
Assemble Glass Door
Brackets as shown

This manual suits for next models

2

Other Securitron Lock manuals

Securitron ASSA ABLOY Magnalock DEM680E Series Manual

Securitron

Securitron ASSA ABLOY Magnalock DEM680E Series Manual

Securitron Magnalock M32 User manual

Securitron

Securitron Magnalock M32 User manual

Securitron Vista V2M1200 User manual

Securitron

Securitron Vista V2M1200 User manual

Popular Lock manuals by other brands

schmersal AZM300Z-I1-ST-SD2P-A Instructions for operation

schmersal

schmersal AZM300Z-I1-ST-SD2P-A Instructions for operation

Lippert 1520 Series owner's manual

Lippert

Lippert 1520 Series owner's manual

TriTeq MicroIQ installation instructions

TriTeq

TriTeq MicroIQ installation instructions

KEYA TRONIC PLUS Assembly

KEYA

KEYA TRONIC PLUS Assembly

Yale 501F installation instructions

Yale

Yale 501F installation instructions

Dorma ARCOS Office Mounting instructions

Dorma

Dorma ARCOS Office Mounting instructions

Nuctech SL3601 user manual

Nuctech

Nuctech SL3601 user manual

Schlage BE489WB user manual

Schlage

Schlage BE489WB user manual

Securam SafeLogic C10 D-Drive operating instructions

Securam

Securam SafeLogic C10 D-Drive operating instructions

COMPX C8142-3 Dimensional drawing

COMPX

COMPX C8142-3 Dimensional drawing

LockMasters X-Lock X-O7 instructions

LockMasters

LockMasters X-Lock X-O7 instructions

Yakima SKS Lock Core quick start guide

Yakima

Yakima SKS Lock Core quick start guide

StarTech.com CONNLOCKPK quick start guide

StarTech.com

StarTech.com CONNLOCKPK quick start guide

Roger SL1000A manual

Roger

Roger SL1000A manual

Igloohome IGP1 manual

Igloohome

Igloohome IGP1 manual

Videx 4900 Installation instruction

Videx

Videx 4900 Installation instruction

D&D Technologies MAGNALATCH RE-KEYING SOP manual

D&D Technologies

D&D Technologies MAGNALATCH RE-KEYING SOP manual

AIRBOLT AirBolt user manual

AIRBOLT

AIRBOLT AirBolt user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.