Secutron MR-2312-AT User manual

INSTALLATION
MANUAL
Revision 1 101007
Document #: LT-658SEC
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual should be read carefully.
MR-2312-AT
Fire Alarm Control Unit


MR-2312-AT Remote Annunciator Wiring and Instruction Manual
i
Table of Contents
Introduction ............................................................................................................................. 1
Technical Support................................................................................................................ 1
Installation Instructions.......................................................................................................... 2
Controls and Displays ............................................................................................................ 2
Wiring Instructions.................................................................................................................. 3
DIP Switch Settings................................................................................................................. 4
Jumper Selection ................................................................................................................. 4
Specifications and Features................................................................................................... 5
Enclosure............................................................................................................................. 5
Electrical Specifications ....................................................................................................... 5
Current Drain for Battery Calculations ................................................................................. 5
Warranty and Warning Information ....................................................................................... 6
Warning Please Read Carefully........................................................................................... 6
Limited Warranty.................................................................................................................. 8
Warranty Procedure............................................................................................................. 8
Disclaimer of Warranties...................................................................................................... 8
Out of Warranty Repairs ...................................................................................................... 9


MR-2312-AT Remote Annunciator Wiring and Instruction Manual
1
Introduction
Secutron’s MR-2312-AT Annunciator is a 16-circuit annunciator for use with Secutron’s MR-2300
Series Fire Alarm Control Panels. Annunciators mount into standard four-gang electrical boxes, and
may not be expanded. Control access is by a keyswitch. Each circuit indicator is a bi-colour LED that is
automatically configured to match the fire alarm control panel configuration.
Technical Support
For all technical support inquiries, please contact Secutron’s Technical Support Department between 8
A.M. and 5 P.M. (EDT) Monday through Friday, excluding holidays.
Note: For ULC S527 applications the MR-2312-AT is an ancillary display device.
Local Phone: 905-695-3545 Toll-Free Phone: 1-888SECUTRON
Local Fax: 905-660-4113 Toll-Free Fax: 1-888-660-4113

Installation Instructions
2
Installation Instructions
Controls and Displays
For precise definitions of control & display operation, refer to the manual of the fire alarm control panel that
the annunciator will be connected to.
Notes:
• The MR-2312-AT is supplied with NP-386 paper labels for zone identification.
• This annunciator displays initiating circuit status only (no individual circuit troubles).
Indicating and relay circuits are not remotely displayed. For more details, refer to the
manual of the fire alarm control panel that the annunciator will be connected to.
• The MR-2312-AT has a keyswitch to enable the four slide-switch controls. The key
should be appropriately secured.
Controls Displays
System Reset, Signal Silence Switches AC On, Common Trouble, Signal Silence LEDs
Buzzer Silence, Lamp Test Switches 16 circuit status bi-coloured (red/amber) LEDs
Standard Electrical
Box
Clear Lexan
Flush Mount
Secure
with
#6-32
Screws
Paper Labels
Wall
Std
Elec.
Box
Std
Elec.
Box
Wall
Surface Mount

MR-2312-AT Remote Annunciator Wiring and Instruction Manual
3
Wiring Instructions
The RS-485 Wiring to the MR-2312-
AT Module is recommended to be
twisted shielded pair as shown in
the diagram. The wire gauge may
be:
• 22 AWG up to 2000 ft.
• 20 AWG up to 4000 ft.
The RS-485 wiring from the fire
alarm control panel to the
annunciator(s) must be point-to-
point from the fire alarm panel to the
first annunciator, then to the next
annunciator, and so on. No star
wiring or T-tapping is allowed. Each
MR-2312-AT Annunciator Module
has a 120 ohm end-of-line resistor
on its RS-485 output terminals. This
is removed on all except the last
wired module.
The 24 VDC field wiring needs to be of an appropriate gauge for the number of annunciators and the
total wiring run length. Use the Current Drain for Battery Calculations on page 5 to calculate the
maximum current for all annunciators summed together.
Note: All circuits are power limited and must use type FPL, FPLR, or FPLP power limited
cable.
WARNING: Accidentally connecting any of the 24 VDC wires to the RS-485 wiring will
result in damage to the annunciator and/or to the fire alarm control panel to which it is
connected.
Total
Maximum
Current for all
Annunciators
Maximum Wiring Run to Last Annunciator Max Loop
Resistance
18AWG 16AWG 14AWG 12AWG 0hms
Amperes ft. mft. mft. mft. mOhms
0.12 1180 360 1850 567 3000 915 4250 1296 15
0.30 470 143 750 229 1200 366 1900 579 6
0.60 235 71 375 114 600 183 850 259 3
0.90 156 47 250 76 400 122 570 174 2
1.20 118 36 185 56 300 91 425 129 1.5
1.50 94 29 150 46 240 73 343 105 1.2
1.70 78 24 125 38 200 61 285 87 1.0
+
24 VDC
OUTPUT
-
S
S
-
+
-
+
-
+
RS-485
OUTPUT
RS-485
INPUT
24 VDC
INPUT 24 VDC POWER FROM FIRE ALARM CONTROL
PANEL OR PREVIOUS ANNUNCIATOR
24 VDC POWER TO
NEXT ANNUNCIATOR
RS-485 TO NEXT ANNUNCIATOR
(TWISTED SHIELDED PAIR)
RS-485 FROM FIRE ALARM OR PREVIOUS
ANNUNCIATOR (TWISTED SHIELDED PAIR)

DIP Switch Settings
4
DIP Switch Settings
Each annunciator needs to be assigned a unique, sequential address via DIP switches SW1-1, SW1-2, and
SW1-3. DIP switch SW1-4 is used to allow disabling of some front panel slide switches.
Set the annunciator address (see the manual for the fire alarm control panel being used), as follows in the
table below:
Annunciators on a common RS-485 connection must be numbered sequentially; i.e.: 1,2,3,4, and not
randomly such as 5,3,7. Note that not all annunciator “addresses” are valid for all fire alarm control panels.
Refer to the fire alarm control panel manual for further information.
Jumper Selection
Jumper JP1 connects pins 2 and 3 and thus provides an eight bit checksum.
JW4
Jumper Intact = Buzzer silence & Lamp Test local function only. System Reset & Signal Silence are
disabled.
Cut Jumper to have all remote functions operate.
SW1-1 = Address A0\
>Three digit address of the annunciator (address
range 1 to 7 inclusive)
SW1-2 = Address A1
SW1-3 = Address A2/
SW1-4 =
When SW1-4 is “off”, the System Reset and Signal Silence slide-switches are
always disabled, regardless of the operation of the keyswitch. The Buzzer
Silence and Lamp Test slide-switches will operate with the use of the
keyswitch.
When SW1-4 is “on”, all four slide -switches on the front panel will operate
with the use of the keyswitch.
Annunciator
Address
SW1 DIP Switch Settings
SW1-1 SW1-2 SW1-3
1ONOFFOFF
2 OFF ON OFF
3ONONOFF
4OFFOFFON
5ONOFFON
6 OFF ON ON
7ONONON

MR-2312-AT Remote Annunciator Wiring and Instruction Manual
5
Specifications and Features
Enclosure
• A standard 4-gang electrical box is used.
Electrical Specifications
• 24 VDC nominal voltage
• Slide-switch controls, LED indicators, and keyswitch to enable controls.
• Local buzzer, indicators (ac-on, common trouble, signal silence), and controls (system reset, lamp
test, buzzer silence, signal silence).
• Annunciation of up to 16 points.
• Not expandable.
• Standby 35 mA Max., All LED’s illuminated 140 mA max.
Current Drain for Battery Calculations
The lamp test feature draws the maximum normal current because it illuminates all lamps on one
chassis at a time. Thus the currents are:
Use the “normal standby current” for battery size calculations (see the fire alarm control panel manual
for battery calculations) and includes the current drain for the Trouble Buzzer, Trouble LED, and one
alarm LED. Use the “maximum current” to calculate the wire size (see the wiring instructions on
page 3).
Normal Standby Current = 35 mA Maximum Current = 140 mA

Warranty & Warning Information
6
Warranty & Warning Information
Warning Please Read Carefully
Note to End Users: This equipment is subject to terms and conditions of sale as follows:
Note to Installers
This warning contains vital information. As the only individual in contact with system users, it is your responsibility to
bring each item in this warning to the attention of the users of this system. Failure to properly inform system end-
users of the circumstances in which the system might fail may result in over-reliance upon the system. As a result, it
is imperative that you properly inform each customer for whom you install the system of the possible forms of
failure.
System Failures
This system has been carefully designed to be as effective as possible. There are circumstances, such as fire or
other types of emergencies where it may not provide protection. Alarm systems of any type may be compromised
deliberately or may fail to operate as expected for a variety of reasons. Some reasons for system failure include:
•Inadequate Installation
A Fire Alarm system must be installed in accordance with all the applicable codes and standards in order to provide
adequate protection. An inspection and approval of the initial installation, or, after any changes to the system, must
be conducted by the Local Authority Having Jurisdiction. Such inspections ensure installation has been carried out
properly.
•Power Failure
Control units, smoke detectors and many other connected devices require an adequate power supply for proper
operation. If the system or any device connected to the system operates from batteries, it is possible for the
batteries to fail. Even if the batteries have not failed, they must be fully charged, in good condition and installed
correctly. If a device operates only by AC power, any interruption, however brief, will render that device inoperative
while it does not have power. Power interruptions of any length are often accompanied by voltage fluctuations which
may damage electronic equipment such as a fire alarm system. After a power interruption has occurred,
immediately conduct a complete system test to ensure that the system operates as intended.
•Failure of Replaceable Batteries
Systems with wireless transmitters have been designed to provide several years of battery life under normal
conditions. The expected battery life is a function of the device environment, usage and type. Ambient conditions
such as high humidity, high or low temperatures, or large temperature fluctuations may reduce the expected battery
life. While each transmitting device has a low battery monitor which identifies when the batteries need to be
replaced, this monitor may fail to operate as expected. Regular testing and maintenance will keep the system in
good operating condition.
•Compromise of Radio Frequency (Wireless) Devices
Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the
radio path or deliberate jamming or other inadvertent radio signal interference.
•System Users
A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical
disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is important that all
system users be trained in the correct operation of the alarm system and that they know how to respond when the
system indicates an alarm.
•Automatic Alarm Initiating Devices
Smoke detectors, heat detectors and other alarm initiating devices that are a part of this system may not properly
detect a fire condition or signal the control panel to alert occupants of a fire condition for a number of reasons, such

MR-2312-AT Remote Annunciator Wiring and Instruction Manual
7
as: the smoke detectors or heat detector may have been improperly installed or positioned; smoke or heat may not
be able to reach the alarm initiating device, such as when the fire is in a chimney, walls or roofs, or on the other side
of closed doors; and, smoke and heat detectors may not detect smoke or heat from fires on another level of the
residence or building.
•Software
Most Secutron products contain software. With respect to those products, Secutron does not warranty that the
operation of the software will be uninterrupted or error-free or that the software will meet any other standard of
performance, or that the functions or performance of the software will meet the user’s requirements. Secutron shall
not be liable for any delays, breakdowns, interruptions, loss, destruction, alteration or other problems in the use of a
product arising our of, or caused by, the software.
Every fire is different in the amount and rate at which smoke and heat are generated. Smoke detectors cannot
sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by
carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of
flammable materials, overloaded electrical circuits, children playing with matches or arson.
Even if the smoke detector or heat detector operates as intended, there may be circumstances when there is
insufficient warning to allow all occupants to escape in time to avoid injury or death.
•Alarm Notification Appliances
Alarm Notification Appliances such as sirens, bells, horns, or strobes may not warn people or waken someone
sleeping if there is an intervening wall or door. If notification appliances are located on a different level of the
residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible notification
appliances may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or
other appliances, or passing traffic. Audible notification appliances, however loud, may not be heard by a hearing-
impaired person.
•Telephone Lines
If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also
the telephone lines may be compromised by such things as criminal tampering, local construction, storms or
earthquakes.
•Insufficient Time
There may be circumstances when the system will operate as intended, yet the occupants will not be protected from
the emergency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the
response may not occur in time enough to protect the occupants or their belongings.
•Component Failure
Although every effort has been made to make this system as reliable as possible, the system may fail to function as
intended due to the failure of a component.
•Inadequate Testing
Most problems that would prevent an alarm system from operating as intended can be discovered by regular testing
and maintenance. The complete system should be tested as required by national standards and the Local Authority
Having Jurisdiction and immediately after a fire, storm, earthquake, accident, or any kind of construction activity
inside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm indicating
devices and any other operational devices that are part of the system.
•Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system
also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the
harmful effects of an emergency situation.
IMPORTANT NOTE: End-users of the system must take care to ensure that the system, batteries, telephone lines,
etc. are tested and examined on a regular basis to ensure the minimization of system failure.

Warranty & Warning Information
8
Limited Warranty
Secutron Inc. warrants the original purchaser that for a period of two years from the date of manufacture, the
product shall be free of defects in materials and workmanship under normal use. During the warranty period,
Secutron Inc. shall, at its option, repair or replace any defective product upon return of the product to its factory, at
no charge for labor and materials. Any replacement and/or repaired parts are warranted for the remainder of the
original warranty or ninety (90) days, whichever is longer. The original owner must promptly notify Secutron Inc. in
writing that there is defect in material or workmanship, such written notice to be received in all events prior to
expiration of the warranty period.
International Warranty
The warranty for international customers is the same as for any customer within Canada and the United States, with
the exception that Secutron Inc. shall not be responsible for any customs fees, taxes, or VAT that may be due.
Conditions to Void Warranty
This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover:
•damage incurred in shipping or handling;
•damage caused by disaster such as fire, flood, wind, earthquake or lightning;
•damage due to causes beyond the control of Secutron Inc. such as excessive voltage, mechanical shock or
•water damage;
•damage caused by unauthorized attachment, alterations, modifications or foreign objects;
•damage caused by peripherals (unless such peripherals were supplied by Secutron Inc.);
•defects caused by failure to provide a suitable installation environment for the products;
•damage caused by use of the products for purposes other than those for which it was designed;
•damage from improper maintenance;
•damage arising out of any other abuse, mishandling or improper application of the products.
Warranty Procedure
To obtain service under this warranty, please return the item(s) in question to the point of purchase. All authorized
distributors and dealers have a warranty program. Anyone returning goods to Secutron Inc. must first obtain an
authorization number. Secutron Inc. will not accept any shipment whatsoever for which prior authorization has not
been obtained. NOTE: Unless specific pre-authorization in writing is obtained from Summit management, no credits
will be issued for custom fabricated products or parts or for complete fire alarm system. Summit will at its sole
option, repair or replace parts under warranty. Advance replacements for such items must be purchased.
Note: Secutron Inc.’s liability for failure to repair the product under this warranty after a reasonable number of
attempts will be limited to a replacement of the product, as the exclusive remedy for breach of warranty.

MR-2312-AT Remote Annunciator Wiring and Instruction Manual
9
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether
expressed or implied (including all implied warranties of merchantability or fitness for a particular purpose) And
of all other obligations or liabilities on the part of Secutron Inc. neither assumes nor authorizes any other person
purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or
liability concerning this product.
This disclaimer of warranties and limited warranty are governed by the laws of the province of Ontario, Canada.
Out of Warranty Repairs
Secutron Inc. will at its option repair or replace out-of-warranty products which are returned to its factory
according to the following conditions. Anyone returning goods to Secutron Inc. must first obtain an authorization
number. Secutron Inc. will not accept any shipment whatsoever for which prior authorization has not been
obtained.
Products which Secutron Inc. determines to be repairable will be repaired and returned. A set fee which
Secutron Inc. has predetermined and which may be revised from time to time, will be charged for each unit
repaired.
Products which Secutron Inc. determines not to be repairable will be replaced by the nearest equivalent product
available at that time. The current market price of the replacement product will be charged for each replacement
unit.
WARNING: Secutron Inc. recommends that the entire system be completely tested on a regular basis.
However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical
disruption, it is possible for this product to fail to perform as expected.
NOTE: Under no circumstances shall Secutron Inc. be liable for any special, incidental, or
consequential damages based upon breach of warranty, breach of contract, negligence, strict
liability, or any other legal theory. Such damages include, but are not limited to, loss of profits, loss of
the product or any associated equipment, cost of capital, cost of substitute or replacement
equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including
customers, and injury to property.
SECUTRON MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE WITH RESPECT TO ITS GOODS DELIVERED, NOR IS THERE ANY OTHER WARRANTY,
EXPRESSED OR IMPLIED, EXCEPT FOR THE WARRANTY CONTAINED HEREIN.

Warranty & Warning Information
10

MR-2312-AT Remote Annunciator Wiring and Instruction Manual
11

© 2007 Secutron, Inc.
Canada
25 Interchange Way
Vaughan, ON L4K 5W3
Tel: (888) SECUTRON
(888) 732-8876
Fax: (905) 660-4113
U.S.A
60 Industrial Parkway, PMB 278
Cheektowaga, New York 14227
Tel: (888) SECUTRON
(888) 732-8876
Fax: (905) 660-4113
No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into
any language or computer language, in any form by any
means electronic, magnetic, optical, chemical, manual, or
otherwise without the prior consent of Secutron.
Table of contents
Other Secutron Fire Alarm manuals
Popular Fire Alarm manuals by other brands

olympia electronics
olympia electronics BSR-2104/MAR Operation and installation manual

Brooks
Brooks RFP V2 Series Operation & installation manual

UTC Fire and Security
UTC Fire and Security Aritech DM2010 Installation sheet

Teletek electronics
Teletek electronics TTE Combo Installation instruction

Teknim
Teknim TFS-3191R Installation & operating guide

Bosch
Bosch B925F installation guide

Bosch
Bosch FAP-420 Series quick guide

SILENT KNIGHT
SILENT KNIGHT INTELLIKNIGHT 5820XL Installation and operation manual

LST
LST SIM216-1 Specification sheet

Ampac
Ampac FireFinder NZS 4512 installation guide

Simplex
Simplex 4100ESi installation instructions

Mircom
Mircom RAM-300LCD Series Installation and operation manual