3 | Installation
2.1 | Access the address switches
1 | Overview
Caution!
Remove all power (AC and battery) before making any
connections. Failure to do so might result in personal
injury and/or equipment damage.
5 | Status indicators
Status
indicator
Function
Ready to turn on (arm)
Turned on (armed)
GAS Gas alarm
AC (Mains) power present
Fire keypad
indicator
Function
Fire alarm
Silenced
Supervisory condition
System trouble
Adjusting nightlight (for control panels with version 2.01 or
higher):
1. Press [MENU] or press [CMD][8] to open the Main menu.
2. Use [NEXT] to go to the Press 5 for Settings Menu option,
or simply press [5].
3. Use [NEXT] to go to the Press 4 for Keypad Config option,
or simply press [4].
4. Use [NEXT] to go to the Press 4 for Nightlight option, or
simply press [4].
5. Use [PREV] or [NEXT] to toggle between the Yes and No
options.
6. Press [ENTER] while viewing the desired option to save the
programming.
7. Press [ESC] to exit the menu.
Adjusting the brightness:
1. Press [MENU] or press [CMD][8] to open the Main menu.
2. Use [NEXT] to go to the Press 5 for Settings Menu option,
or simply press [5].
3. Use [NEXT] to go to the Press 4 for Keypad Config option,
or simply press [4].
4. Press [1] to adjust the brightness.
5. Use [PREV] or [NEXT] to adjust the brightness level. The
changes apply immediately.
6. Press [ESC] to exit the menu.
4 | Display
3.1 | Install the keypad
3.2 | Attaching to the control panel
You can surface install the keypad, or install it to standard
electrical boxes, including single gang boxes.
1. Use the base as a template to mark surface.
2. Pull the wiring through the opening in the base.
3. Use the mounting hardware to attach.
Use the control panel terminals labeled R, Y, G, B (PWR, A, B,
COM). Connect them to the keypad terminals labeled R, Y, G, B.
Keypads can be wired directly to the control panel or from
keypad to keypad.
Callout ― Description
1 ― Control panel
2 ― Terminal wiring
3 ― Keypad’s wiring terminal block
12
3
R
Y
G
B
SDI2
PWR+/R
A/Y
B/G
COM/B
27
28
29
26
e
SDI2
PWR+/R
A/Y
B/G
COM/B
28
29
30
27
e
Reconnect the keypad to the base by sliding the keypad onto
the base (reverse of Step 2). Apply power to the system.
SDI2
PWR+/R
A/Y
B/G
COM/B
27
28
29
26
e
SDI2
PWR+/R
A/Y
B/G
COM/B
28
29
30
27
e
R
Y
G
B
2 | SDI2 address switches
Two switches set the address for the keypad. The control panel
uses the address for communication.
GAS
GAS
Set the address switches per the control panel configuration.
Each SDI2 keypad must have a unique address. For single-
digit addresses 1 through 9, set the tens switch to 0. The
following illustration shows the address switch setting for
address 1.
Callout ― Description
1 ― Address switches
1
2.2 | Setting the address switches
1. Use a slotted screwdriver. Turn the lock counter-
clockwise.
2. Push down on the keypad to remove it from the base.
3. Find the switches on the back of the keypad.
Refer to the following illustrations.
1
2
This keypad is an SDI2 bus compatible
Callout ― Description
1 ― Wall mount holes
2 ― Single gang box holes
3 ― Double gang box holes
4 ― Wire opening
5 ― Surface mount wire openings
6 ― Gang box holes (3-4 in)
7 ― Surface mount wire channel
8 ― Bubble level
9 ― SDI2 wiring terminal block
10 ― Wire tie posts
R Y G B
62
4
9
12
3
3
7 7 5
5
11
10
665
8
10
10
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
© 2018 Bosch Security Systems, Inc. F.01U.305.193 | 04 | 2018.05
Copyright
This document is the intellectual property of Bosch Security
Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and must be
treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to
the Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
El-gr: Μεταβείτε στη διεύθυνση https://gr.boschsecurity.com/el/ για την
τεκμηρίωση σε αυτήν τη γλώσσα.
Es-es: Visite https://es.boschsecurity.com/es/ para obtener documentación en
este idioma.
Fr-fr: Accédez à l’adresse https://fr.boschsecurity.com/fr/ pour obtenir la
documentation dans cette langue.
Hu-hu: A honosított dokumentációt lásd a https://hu.boschsecurity.com/hu/
oldalon.
It-it: Andare a https://it.boschsecurity.com/it/ per la documentazione in questa
lingua.
Pl-pl: Dokumentacja w tym języku znajduje się w witrynie https://
pl.boschsecurity.com/pl/
Pt-br: Acesse http://pt.boschsecurity.com/pt/ para obter a documentação
neste idioma.
11 | Specifications
Dimensions 6.2 in x 4.7 in x 1 in (158 mm x
120 mm x 26 mm)
Voltage (input) 12 VDC nominal
Current (maximum) Standby: 35 mA
Alarm: 70 mA
Operating temperature 0°C to +50°C (+32°F to +122°F)
Relative humidity 5% to 93% at +32°C (+90°F)
non-condensing
Terminal wire size 12 AWG to 22 AWG (2 mm to
0.65 mm)
SDI2 wiring Maximum distance - wire size
(unshielded wire only):
1000 ft (305 m) - 22 AWG (0.65
mm)
Compatibility B9512G/B9512G-E
B8512G/B8512G-E
(Refer to the compatible control
panel installation document for
device capacity.)
Region Certification
CA Canada CAN/ULC S303 - Local Burglar Alarm
Units and Systems
CAN/ULC S304 - Signal Receiving Centre and
Premise Alarm Control Units
CAN/ULC S545 - Residential Fire Warning System
Control
Units
ULC-ORD C1023 - Household Burglar Alarm
System Units
ULC-ORD C1076 - Proprietary Burglar Alarm
Units and Systems
ICES-003 - Digital Apparatus
10 | Certifications
Region Certification
US UL 365 - Police Station Connected Burglar Alarm
Units and Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and Systems
UL 864 - Control Units and Accessories for Fire
Alarm Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System Units
UL 1076 - Proprietary Burglar Alarm Units and
Systems
UL 1610 - Central Station Burglar Alarm Units
CSFM - California Office of The State Fire
Marshal
FCC Part 15 Class B
8 | Firmware version
NOTICE!
You can also view a keypad’s firmware version in RPS.
1. To remove power to the keypad, remove it from the base.
2. Return the keypad to the base to restore power.
The keypad shows the
model number, keypad address, and
firmware version for 10 seconds.
7 | Supervision
The control panel supervises all SDI2 devices. Any device
that fails to respond will be declared missing.
6 | Audible tones
The keypad has a built-in speaker that produces several distinct
warning tones.
Tone Description
Fire alarm Emits a pulsed, high-pitched bell tone.
Gas alarm Emits a unique high pitched tone.
User alarm The tone sounds for the programmed
amount of time.
Burglary alarm Emits a steady, high pitched bell tone.
Entry delay Emits an intermittent beep tone during entry
delay periods.
Exit delay Emits an intermittent beep tone during exit
delay.
Invalid button
buzz
Emits a flat buzz tone.
Keypress Emits a muted beep tone.
Trouble Emits a two-tone warble until you enter a pro-
grammed passcode.
Watch point
fault
Emits a single clean tweedle tone.
9 | Keypad cleaning
Use a soft cloth or a non-abrasive cleaning solution. Spray the cleaner
onto the cloth, not the keypad.
en Installation Guide
Fire Keypad
B925F/B926F

This manual suits for next models

1

Other Bosch Fire Alarm manuals

Bosch FPC-500 User manual

Bosch

Bosch FPC-500 User manual

Bosch FAP-420 Series User manual

Bosch

Bosch FAP-420 Series User manual

Bosch FMC-420RW-GSRRD User manual

Bosch

Bosch FMC-420RW-GSRRD User manual

Bosch FAP-O 500 Series User manual

Bosch

Bosch FAP-O 500 Series User manual

Bosch FPA-1000-UL Operating instructions

Bosch

Bosch FPA-1000-UL Operating instructions

Bosch FAP-DO420 User manual

Bosch

Bosch FAP-DO420 User manual

Bosch FPA-5000 User guide

Bosch

Bosch FPA-5000 User guide

Bosch D1256 User manual

Bosch

Bosch D1256 User manual

Bosch FPA-1000 Series How to use

Bosch

Bosch FPA-1000 Series How to use

Bosch FSM-2000 User manual

Bosch

Bosch FSM-2000 User manual

Bosch FPC-500-2 User manual

Bosch

Bosch FPC-500-2 User manual

Bosch LSN Operator's manual

Bosch

Bosch LSN Operator's manual

Bosch FPA-5000 User manual

Bosch

Bosch FPA-5000 User manual

Bosch FMM-7045 Series User manual

Bosch

Bosch FMM-7045 Series User manual

Bosch DOW 1171 User manual

Bosch

Bosch DOW 1171 User manual

Bosch FMC-300RW-GSRRD User manual

Bosch

Bosch FMC-300RW-GSRRD User manual

Bosch FMC-420RW-GFRRD User manual

Bosch

Bosch FMC-420RW-GFRRD User manual

Bosch FCP-320 Series User manual

Bosch

Bosch FCP-320 Series User manual

Bosch FPC-500 User manual

Bosch

Bosch FPC-500 User manual

Bosch FAP-DO420 User manual

Bosch

Bosch FAP-DO420 User manual

Bosch FNS-420-R User manual

Bosch

Bosch FNS-420-R User manual

Bosch FMM-7045 User manual

Bosch

Bosch FMM-7045 User manual

Bosch FMC-300RW-GSGYE User manual

Bosch

Bosch FMC-300RW-GSGYE User manual

Bosch AVENAR FAP-425 User manual

Bosch

Bosch AVENAR FAP-425 User manual

Popular Fire Alarm manuals by other brands

Ziton ZP755R-2 Installation sheet

Ziton

Ziton ZP755R-2 Installation sheet

CWSI CP-3000A quick start guide

CWSI

CWSI CP-3000A quick start guide

Honeywell SILENT KNIGHT SWIFT instruction manual

Honeywell

Honeywell SILENT KNIGHT SWIFT instruction manual

Araani FireCatcher user manual

Araani

Araani FireCatcher user manual

Panasonic EBL512 operating instructions

Panasonic

Panasonic EBL512 operating instructions

Siemens FC901 System Installation Instructions

Siemens

Siemens FC901 System Installation Instructions

SilentCall SK2-SS Sidekick II Signature Series user guide

SilentCall

SilentCall SK2-SS Sidekick II Signature Series user guide

Global JUNO-NET Operation & maintenance manual

Global

Global JUNO-NET Operation & maintenance manual

SILENT KNIGHT 4224 installation manual

SILENT KNIGHT

SILENT KNIGHT 4224 installation manual

Monaco C-99A Installation, operation, maitenance manual

Monaco

Monaco C-99A Installation, operation, maitenance manual

Potter FFT-1000 installation manual

Potter

Potter FFT-1000 installation manual

Siemens FS720 Series Commissioning, Maintenance, Troubleshooting

Siemens

Siemens FS720 Series Commissioning, Maintenance, Troubleshooting

Panasonic Firetracker FT1020G3 CIE Operation manual

Panasonic

Panasonic Firetracker FT1020G3 CIE Operation manual

Consilium Salwico CS4000 Service maintenance manual

Consilium

Consilium Salwico CS4000 Service maintenance manual

ICAS 500-ID Series manual

ICAS

ICAS 500-ID Series manual

Zeta QT/1 User manual, maintenance guide & log book

Zeta

Zeta QT/1 User manual, maintenance guide & log book

C-TEC FF596 installation instructions

C-TEC

C-TEC FF596 installation instructions

EST SAN-4 installation manual

EST

EST SAN-4 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.