3/11
[4] Environment and Mechanical characteristics
Item Specifications Conditions
1 High temperature storage Δf/f0 = ±10×10-6 After storage under 125℃ for 1000 hours, *1
measure at room temperature. *3
2 Low temperature storage Δf/f0 = ±10×10-6 After storage under -40℃ for 1000 hours, *1
measure at room temperature. *3
3 High temperature and Δf/f0 = ±10×10-6 After storage under +85±2℃ , *1
high humidity storage 85 % RH for 1000h, measure at room *3
temperature.
4 Thermal shock resistance Δf/f0 = ±10×10-6 Measure at room temperature after *1
100 cycles. *3
-55℃ ⇔ +125℃ for 30 minutes.
5 Mechanical shock Δf/f0 = ±10×10-6 *2
resistance
6 Vibration resistance Δf/f0 = ±10×10-6 Amplitude 1.5mm and 10~60Hz with *2
cycle time 2~3 minutes in 3 direction
(X,Y,and Z axis) each for 2 h.
7 IR Reflow Δf/f0 = ±10×10-6 Measure after 2 time reflow under *1
reflow profile specified in page 10
8 Shear strength No peeling-off Pressuring force 10N×10±1sec. *2
according to IEC60068-2-21
9 Peel strength No peeling-off Pressuring force 10N×10±1sec. *2
according to IEC60068-2-21
10 Bending test No peeling-off Bending: 3mm×5±1sec. *2
Thickness of the testing board: 1mm
Note:
1. Each test shall be done independently. (not in series tests)
2. *1: Measure after 24 hours left at room temperature.
3. *2: Measure after 2 hours left at room temperature.
4. *3: Pre conditions
(1) IR Reflow : 2 times
(2) Initial values shall be measured after 24 hours at room temperature.
5. Shift in series resistance after the above tests shall be less than ±20% or less than ±15kΩ.
In case of resistance to IR reflow and high temperature storage(±125℃ for 1000 hours), shift in
series resistance after the above tests shall be less than ±30% or ±20kΩ.
Measure after 100g-dummy(SII Standard)
drop from 1500mm height on the concrete
3directions 10times.