Seiko Conceptual SNE527P User manual

INSTRUCTION MANUAL FOR WATCH CALIBRE
V158
THIS PRODUCT CONTAINS A BUTTON BATTERY
If swallowed or placed inside any part of the body, the battery can
cause severe or fatal injuries within 2 hours or less.
Button batteries are hazardous whether new or used. Keep batteries
out of reach of children.
If you think the battery may have been swallowed or placed inside any
part of the body, seek immediate medical attention. Contact the
Australian Poisons Information Centre immediately on 13 11 26
(New Zealand 0800 764 766) for 24 / 7 fast, expert advice.

Cal. V110, V111, V114, V115, V116, V117, V137,
V145, V147, V157, V158, V181, V182 & V187
INSTRUCTIONS (P. 4)
BEDIENUNGSANLEITUNG (S. 18)
INSTRUCTIONS (P. 33)
ISTRUZIONI (P. 47)
INSTRUCCIONES (P. 62)
INSTRUÇÕES (P. 76)
ИНСТРУКЦИИ (P. 90)
(106 )

You are now the proud owner of a SEIKO Solar Cal. V110/V111/V114/V115/V116/V117/V137/V145/V147/
V157/V158/V181/V182/V187. For the best results, please read the instructions in this booklet carefully before
using it. Please keep this manual handy for ready reference.
Wir gratulieren Ihnen zum Kauf der SEIKO Solar Kal. V110/V111/V114/V115/V116/ V117/V137/V145/V147/
V157/V158/V181/V182/V187. Lesen Sie diese Bedienungsanleitung vor der Verwendung aufmerksam durch,
um ihre optimale Nutzung zu gewährleisten. Heben Sie diese Bedienungsanleitung gut auf, um jederzeit
wieder nachlesen zu können.
Vous êtes maintenant l’heureux propriétaire d’une montre solaire SEIKO Cal. V110/V111/V114/V115/V116/
V117/V137/V145/V147/V157/V158/V181/V182/ V187. Pour en obtenir des performances optimales, veuillez
lire attentivement cette brochure avant d'utiliser la montre. Conservez ce manuel pour vous y référer en
cas de besoin.
Grazie di aver acquistato questo orologio SEIKO Solar Cal. V110/V111/V114/V115/V116/V117/V137/V145/
V147/V157/V158/V181/V182/V187. Per poter utilizzare l’orologio al massimo delle sue prestazioni leggere
attentamente questo manuale di istruzioni prima di passare all’uso dell’orologio stesso, e conservarlo poi
per qualsiasi eventuale futura consultazione.
Usted es ahora un orgulloso propietario de un SEIKO Solar Cal. V110/V111/V114/V115/V116/V117/V137/
V145/V147/V157/V158/V181/V182/V187. Para los mejores resultados, por favor, lea cuidadosamente las
instrucciones de este panfleto antes utilizar su Reloj SEIKO. Por favor, guarde este manual en un lugar
conveniente para su futura referencia.
Agora pode sentir-se orgulhoso de possuir um SEIKO Solar Cal. V110/V111/V114/V115/V116/V117/V137/
V145/V147/V157/V158/V181/V182/V187.Para obter os melhores resultados, leia atentamente as instruções
contidas neste opúsculo antes de usá-lo. Conserve este manual para consultas futuras.
Теперь Вы являетесь обладателем часов Сейко Соляр (Seiko Solar) Калибра V110/V111/V114/
V115/
V116 / V117
/
V137 /
V145/V147/V157/V158/V181/V182/V187. Перед использованием их, для достижения
лучших результатов, пожалуйста, внимательно ознакомьтесь с данной инструкцией и обязательно
сохраните ее.
歡迎購買精工
V110/V111/V114/V115/V116/V117/V137/V145/V147/V157/V158/V181/V182/V187
機型
太陽能手錶

5
English
4
ENGLISH
IFor the care of your watch, see “TO PRESERVE THE QUALITY OF YOUR
WATCH” in the attached Worldwide Guarantee and Instruction Booklet.
CONTENTS
page
FEATURES...................................................................................................... 5
HOW TO CHARGE AND START THE WATCH .............................................. 6
TIME/CALENDAR SETTING.......................................................................... 8
GUIDELINE OF CHARGING TIME/ACCURACY............................................ 10
ENERGY DEPLETION FOREWARNING FUNCTION .................................... 13
NOTE ON POWER SUPPLY........................................................................... 14
HOW TO OPERATE THE SCREW LOCK TYPE CROWN.............................. 15
ROTATING BEZEL .......................................................................................... 16
SPECIFICATIONS ........................................................................................... 17
FEATURES
nPOWERED BY LIGHT ENERGY
nNO BATTERY CHANGE REQUIRED (Please refer to page 14 "NOTE ON POWER
SU PPLY " )
nLASTS FOR 2 TO 12 MONTHS AFTER FULL CHARGE (DEPENDS ON THE
CALIBRE)
nENERGY DEPLETION FOREWARNING FUNCTION (FOR CAL. V111, V117, V137,
V145, V147, V157, V158, V181, V182, V187 ONLY)
nINSTANT-START FUNCTION (FOR CAL. V145, V147, V157, V158, V181, V182,
V187 ONLY)
nOVERCHARGING PREVENTION FUNCTION
CAL. V110, V111, V114, V115, V116, V117, V137,
V145, V147, V157, V158, V181, V182 & V187
lCalibre number of your watch
Please check the case back of your watch to find
its calibre number inscribed on it. As illustrated at
right, the calibre number of your watch is the 4-digit
number to the left of the hyphen mark.
AQ
V145-0A00
Calibre No.

7
English
English
6
HOW TO CHARGE AND START THE WATCH
lWhen you start the watch or when the energy in the rechargeable battery is
reduced to an extremely low level, charge it sufficiently by exposing the watch
to light.
lInstant-start function:
When the watch is exposed to sunlight or strong artificial light (of more than
1,000 lux), it will start operating immediately with the second hand moving at
2-second intervals.
1 Exp o se t h e w a tc h t o s u nlight or s tron g
artificial light.
• Whenthewatchhasstoppedoperating,thesecond
handwillstartmovingat2-secondintervals.
2 Keep the watch exposed to the light until the
second hand moves at 1-second intervals.
3 When the wat c h is c h ar g ed a fter i t ha s
completely stopped, set the date and time
before wearing the watch.
•
See “GUIDELINE OF CHARGING TIME/ACCURACY” .
▲
▲
NOTES :
1. Ifyourwatchhasasecondhand,whentheinstant-startfunctionisactivatedafter
thewatchisexposedtolight,thesecondhandstartsmovingat2-secondintervals
immediately,buttheenergystoredintherechargeablebatteryisnotsufcient.If
thewatchisturnedawayfromthelight,itmaystopoperating.
2. Itisnotnecessarytochargethewatchfully.Itisimportant,however,tocharge
thewatchsufciently,especiallyincaseofinitialcharge.
Caution for charging
lWhen char ging the wa tch, do not pla ce i t too close to a photof lash
light, spotlight, incandescent light or other light sources as the watch
temperature will become extremely high, causing damage to the parts
inside the watch.
lWhen exposing the watch to sunlight to charge it, do not leave it on the
dashboard of a car, etc. for a long time, as the watch temperature becomes
extremely high.
lWhile charging the watch, make sure the watch temperature does not
exceed 50 °C. (For Cal. V110, V145, V181 and V182)
l
While charging the watch, make sure the watch temperature does not exceed
60 °C. (For Cal. V111, V114, V115, V116, V117, V137, V147, V157, V158 and V187)
CAUTION

9
English
English
8
NOTES :
1. Donotsetthedatebetween9:00p.m.and1:00a.m.Otherwise,itmaynotchangeproperly.
•
Ifitisnecessarytosetthedateduringthattimeperiod,rstchangethetimetoanytime
outside it, set the date and then reset the correct time.
2. Whensettingthehourhand,checkthatAM/PMiscorrectlyset.
•
Thewatchissodesignedthatthedatechangesoncein24hours.Turnthehandspastthe
12o’clockmarkertodeterminewhetherthewatchissetfortheA.M.orP.M.period.Ifthe
datechanges,thetimeissetfortheA.M.period.Ifthedatedoesnotchange,thetimeis
setfortheP.M.period.
3. Whensettingtheminutehand,rstadvanceit4to5minutesaheadofthedesiredtimeandthen
turn it back to the exact minute.
4. ItisnecessarytoadjustthedateattheendofFebruaryand30-daymonths.
TIME/CALENDAR SETTING
1. Pull out the crown to the first click.
2. Turn the crown to set the desired time.
3. Push b a ck the crown comple tely ( in
accordance with a time signal for a three-
hand model.)
lModels with two/three hands
lModels with date
1. Pull out the crown to the first click and set
the previous date.
2. P ull out th e c row n to th e s econd click
when the second hand is at the 12 o'clock
position.
3. Turn th e c row n un t il the de s ire d d a te
appears.
4. Turn the crown to set the hour and minute
hands to the desired time.
5. Push bac k the cr o w n co m p le t e l y in
accordance with a time signal.
Second hand
Minute hand
Hour hand
Date
lModels with day and date
1. Pull out the crown to the first click and set
the previous day and date.
2. Pull out the crown to the s e co n d c lic k
when the second hand is at the 12 o'clock
position.
3. Turn the crown until the desired day and
date appears.
4. Turn the crown to set the hour and minute
hands to the desired time.
5. Push b a ck t h e c r own c o m p l e te l y in
accordance with a time signal.
Date
Day

11
English
English
10
GUIDELINE OF CHARGING TIME/ACCURACY
Environment/Lightsource (lux)
V110 V111/ V117
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
General offices/ Fluorescent light (700)
50 16 140 180 60 -
30W20cm/ Fluorescent light (3000) 11 3.5 30 35 10 180
Cloudy weather/Sunlight (10000) 30.9 812 460
Fair weather/Sunlight (100000) 10.3 2 2 0.5 10
Expected life per charge from full
charge to stoppage 5 months 6 months
Loss/gain (monthly rate)
Less than 20 seconds when the watch
is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC
)
Less than 15 seconds when the watch
is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC)
Operational temperature range -5 ºC to 50 ºC -10 ºC to 60 ºC
A: Time to charge 1 day of power
B: Time required for steady operation
C: Time required for full charge
V114 / V115 / V116 V137 V147/ V157/V158
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
180 60 -110 16 -110 25 -
35 10 180 30 490 30 6120
12 460 81.2 30 10 235
20.5 10 10.1 10 20.4 9
12 months 6 months 10 months
Less than 15 seconds when the watch is worn on your wrist
at a normal temperature range (5 ºC to 35 ºC)
-10 ºC to 60 ºC
vThe above table provides only a general guideline.

13
English
English
12
A: Time to charge 1 day of power
B: Time required for steady operation
C: Time required for full charge
V187 V145 V181/V182
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
A
(minutes)
B
(hours)
C
(hours)
95 8100 50 11 175 75 682
23 1.6 25 10 240 18 1.3 20
60.4 7 3 0.5 10 50.3 5
30.1 3 1 0.1 3 2 0.1 2.1
2 months 6 months 2 months
Less than 15 seconds when the watch
is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC)
Less than 20 seconds when the watch is worn on your wrist at a normal
temperature range (5 ºC to 35 ºC
)
-10 ºC to 60 ºC -5 ºC to 50 ºC
uThe watch operates while charging electricity by converting light received on the dial to electrical
energy. It cannot properly operate unless the remaining energy is sufficient. Place or store the
watch in a location receiving light etc., to sufficiently charge electricity.
•
When the watch is stopped or the second hand starts moving at 2-second intervals (for models
with a second hand,) charge the watch by exposing it to light.
•
The time required for charging the watch varies depending on the calibres. Check the calibre of
your watch engraved on the back cover.
•
It is recommended that the watch be charged for as long as the charging time "B" to assure
the stable movement of the watch.
vThe above table provides only a general guideline.
ENERGY DEPLETION FOREWARNING FUNCTION
vTO PREVENT THE ENERGY DEPLETION
●If your watch has a second hand, when the energy stored in the rechargeable
battery is reduced to an extremely low level, the second hand starts moving
at 2-second intervals instead of the normal 1-second intervals. (Some calibres
have no such function.) The watch remains accurate even while the second
hand is moving at 2-second intervals.
●In that case, recharge the watch as soon as possible by exposing it to light.
Otherwise, the watch may stop operating in about 3 days. (For recharging the
watch, see “HOW TO CHARGE AND START THE WATCH”)
•When wearing the watch, make sure that the watch is not covered by
clothing.
•When the watch is not in use, leave it in a bright place as long as possible.

15
English
English
14
NOTE ON POWER SUPPLY
l The battery used in this watch is a rechargeable battery, which is different
from ordinary silver oxide batteries. Unlike other disposable batteries such as
dry-cell batteries or button cells, this rechargeable battery can be used over
and over again by repeating the cycles of discharging and recharging.
l The capa c i t y or recharging ef ficiency of the rechargeable b a tter y may
gradually deteriorate for various reasons such as long-term use or usage
conditions. Worn or contaminated mechanical parts or degraded oils may
also shorten recharging cycles. If the efficiency of the rechargeable battery
decreases, it is necessary to have the watch repaired.
●Do not remove the rechargeable battery yourself. Replacement of the
rechargeable battery requires professional knowledge and skill. Please
ask a watch retailer for replacement of the rechargeable battery.
●Installation of an ordinary silver oxide battery can generate heat that can
cause bursting and ignition.
CAUTION
lTo unscrew the crown:
Turn the crown counterclockwise. (Then, pull it out for time/calendar setting)
lTo screw in the crown:
With the crown at the normal position, turn it clockwise while pressing it.
HOW TO OPERATE THE SCREW LOCK TYPE
CROWN
(for models with screw lock type crown)

17
English
English
16
ROTATING BEZEL
(for models with rotating bezel)
lThe rotating bezel can show up to 60 minutes of elapsed time.
1 Turn the rotating bezel to align its " "
mark with the minute hand.
Note:Forsomemodels,therotatingbezelrotatesonlycounterclockwise.
Start
Elapsedtime
2 Read the number on the rotating bezel
that the minute hand points to.
30 minutes
haveelapsed.
SPECIFICATIONS
1 Frequency of crystal oscillator ............. 32,768 Hz (Hz = Hertz … Cycles per second)
2 Loss/gain (monthly rate)
For Cal. V110, V145, V181, V182...... ±20 seconds at normal temperature range
(5 °C to 35 °C/ 41 °F to 95 °F)
For Cal. V111, V114, V115, V116, V117, V137, V147, V157, V158, V187
±15 seconds at normal temperature range
(5 °C to 35 °C/ 41 °F to 95 °F)
3 Operational temperature range
For Cal. V110, V145, V181, V182...... –5 °C to 50 °C/ 23 °F to 122 °F
For Cal. V111, V114, V115, V116, V117, V137, V147, V157, V158, V187
–10 °C to 60 °C/ 14 °F to 140 °F
4 Driving system ...................................... Step motor
5 Power supply.........................................
Manganese titanium-lithium rechargeable battery
6 Additional function
For Cal. V145, V147, V157, V158, V181, V182, V187
Instant-start function, energy depletion forewarn-
ing function and overcharging prevention function
For Cal. V111, V117, V137 ................. Energy depletion forewarning function and over-
charging prevention function
For Cal. V110, V114, V115, V116 ......... Overcharging prevention function
7 IC (Integrated Circuit) ........................... C-MOS-IC, 1 piece
• The specications are subject to change without prior notice for product
improvement.
Table of contents
Other Seiko Watch manuals

Seiko
Seiko SSE017J9 User manual

Seiko
Seiko VD 50 B User manual

Seiko
Seiko 7002 User manual

Seiko
Seiko Arctura SKA201 User manual

Seiko
Seiko GRAND SEIKO 9S51 User manual

Seiko
Seiko Presage SPB399J User manual

Seiko
Seiko 8F35 User manual

Seiko
Seiko Astron 3X22 User manual

Seiko
Seiko 7T84 User manual

Seiko
Seiko PRESAGE SRPH78J1 User manual

Seiko
Seiko M-23 2R05 User manual

Seiko
Seiko W850A Quick start guide

Seiko
Seiko Presage SRQ033J User manual

Seiko
Seiko Lorus R23 Series User manual

Seiko
Seiko NH35 User manual

Seiko
Seiko 5M84A User manual

Seiko
Seiko T-4 User manual

Seiko
Seiko 5R64 User manual

Seiko
Seiko GPS SOLAR ASTRON 5X53 User manual

Seiko
Seiko G-8 User manual