SENSIT RLD-2
Refrigerant Gas Detector
Read and understand
instructions before use.
INSTRUCTION MANUAL
SENSIT Technologies
851 Transport Drive • Valparaiso IN 46383
(219) 465-2700 • Fax: (219) 465-2701
www.gasleaksensors.com
SPECIFICATIONS
Power Supply: 3 “C” alkaline batteries
Sensor: Conductive Polymer
Ionization (CPI)
Sensitivity: Selectable to 0.25 oz
/yr 134a
Warm up: Approx. 3 seconds
Response Time: Instantaneous
Duty Cycle: Continuous
Battery Life: Approx. 24 Hours
Size: 3.5” x 10” x 1.6”
(89 x 254 x 40 mm)
Weight: 1.3 lbs. (591 g)
Probe Length: 16”
ACCESSORIES
REPLACEMENT PARTS
PRD0110 Sensor
ISRLD0500 Instruction Manual
ACCESSORIES
PHXG0260 Hard Carrying Case
P014091 Earphone
GENERAL DESCRIPTION
The SENSIT®RLD-2 is a state-of-the-
art refrigerant leak detector capable of
detecting all halogen based gases.
Selectablesensitivitycombinedwithan
adjustable tick rate will allow any
service professional to pinpoint those
tough to find leaks even when the
environment is contaminated by other
gases.
BATTERY REPLACEMENT
If the green light fails to illuminate, the
batteries need replacement. Depress
the latch using a coin and slide the
battery compartment cover off.
Replace the batteries with 3
“C”alkaline batteries.
When replacing the batteries observe
thepolaritymarkingsonthesidesofthe
battery holder. A fresh set of alkaline
batteries should operate the unit for
approximately24hours.
SENSOR REPLACEMENT
Replace the sensor when:
a)The red light remains illuminated at
all times.
b)The response is erratic.
c)There is reduced sensitivity.
1.Turn the unit off.
2.Remove the old sensor by
unscrewing in a counterclockwise
direction.
3.Install a replacement sensor by
screwing in a clockwise direction until
FINGER TIGHT.
4.Do not change the sensor in a
hazardous environment.
WARNING: Turn unit off before
cleaning or replacing the sensor.
Failure to do so may result in a mild
electrical shock.
SCAN MODE
(MOST SENSITIVE)
NORMAL
SENSITIVITY
PRODUCT FEATURES
POWER OFF/ON
VISUAL LEAK
INDICATOR
SENSOR
GOOSENECK
CLIP
EARPHONE
JACK
SPEAKER
(ON BACK)
GREEN
READY
LED
TICK
ADJUST
GOOSENECK
BATTERY
COMPARTMENT
Instrument Operations on other side.
®
SENSIT RLD-2
Refrigerant Gas Detector
INSTRUCTION MANUAL page 2
SENSIT Technologies
851 Transport Drive • Valparaiso IN 46383
(219) 465-2700 • Fax: (219) 465-2701
www.gasleaksensors.com
8/08 V2
OPERATIONS
1. Turn the unit on in an
uncontaminated environment by
moving the switch from the “OFF” to
the “NORM” position.
2. The green ready light will illuminate
if there is ample battery power. The
red LED may flicker and the tick may
sound during the warm up. To silence
the tick, rotate the tick wheel fully
counterclockwise.
3. Adjust the “TICK ADJUST” by
rotating it in a clockwise direction until
a uniform tick begins to sound. The
red light will flash at the same time
the tick sounds.
4. Approach suspected leak areas
with the sensor until the tick begins to
increase. When the tick increases do
not move the sensor from the
suspected leak area, rotate the tick
adjust slightly counterclockwise to
slow the ticking sound and continue to
approach the leak. Continue to slow
the tick until the leak is found.
REMEMBER: An increase in tick
indicates you are approaching a leak,
a decrease in tick indicates you are
moving away.
5. To find extremely small leaks use
the same procedure but operate the
unit in the “SCAN” mode.
6. If the green light does not
illuminate, the batteries must be
replaced.
OPERATIONS continued
7. An earphone can be plugged into
the earphone jack when using this
instrument in noisy areas.
8. If the response is erratic, check the
sensor for tightness and cleanliness.
Cleaning the sensor with alcohol is
permitted with the instrument off.
9. If the instrument does not perform,
replace the sensor. We recommend
sensor replacement before every
season.
WARRANTY AND REPAIR POLICY
Your SENSIT®RLD-2 is warranted to
be free from defects in materials and
workmanship for a period of one year
after purchase (excluding sensor and
batteries).
If within the warranty period your
instrument should become inoperative
from such defects, the unit will be
repairedorreplacedatouroption.
This warranty covers normal use and
doesnotcoverdamagewhichoccursin
shipment or failure which results from
alteration, tampering, accident,
misuse, abuse, neglect, or improper
maintenance.
A purchase receipt or other proof of
date of original purchase will be
required before warranty performance
will be rendered. Instruments out of
warranty will be repaired for a service
charge.
Returntheunitpostpaidandinsuredto:
SENSIT TECHNOLOGIES
851 Transport Drive
Valparaiso, IN 46383
(219) 465-2700
This warranty gives you specific legal
rights and you may also have other
rights which vary from state to state.
SCAN MODE
(MOST SENSITIVE)
NORMAL
SENSITIVITY
PRODUCT FEATURES
POWER OFF/ON
VISUAL LEAK
INDICATOR
SENSOR
GOOSENECK
CLIP
EARPHONE
JACK
SPEAKER
(ON BACK)
GREEN
READY
LED
TICK
ADJUST
GOOSENECK
BATTERY
COMPARTMENT

Other Sensit Security Sensor manuals

Sensit HXG-3P User manual

Sensit

Sensit HXG-3P User manual

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Sensit PMD2 User manual

Sensit

Sensit PMD2 User manual

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Sensit CO Programming manual

Sensit

Sensit CO Programming manual

Sensit TKX User manual

Sensit

Sensit TKX User manual

Sensit HXG-3 User manual

Sensit

Sensit HXG-3 User manual

Sensit TKX User manual

Sensit

Sensit TKX User manual

Sensit VMD Operating instructions

Sensit

Sensit VMD Operating instructions

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Popular Security Sensor manuals by other brands

NuAire 230-PIR installation manual

NuAire

NuAire 230-PIR installation manual

Siemens SLD4 Application notes

Siemens

Siemens SLD4 Application notes

Bentel Security ZT100H quick start guide

Bentel Security

Bentel Security ZT100H quick start guide

Metrotech 9800XT SFL2 Series Operation manual

Metrotech

Metrotech 9800XT SFL2 Series Operation manual

EDWARDS SYSTEMS TECHNOLOGY CRC Technical reference manual

EDWARDS SYSTEMS TECHNOLOGY

EDWARDS SYSTEMS TECHNOLOGY CRC Technical reference manual

Niko 350-20071 manual

Niko

Niko 350-20071 manual

LST B524IEFT-1 Specification sheet

LST

LST B524IEFT-1 Specification sheet

König SAS-DVRPIR10 manual

König

König SAS-DVRPIR10 manual

Pilz PSENslock PSEN sl-1.0p 1.1 VA operating instructions

Pilz

Pilz PSENslock PSEN sl-1.0p 1.1 VA operating instructions

Aegisound DANR THP Operation manual

Aegisound

Aegisound DANR THP Operation manual

Milesight WS302-868M user guide

Milesight

Milesight WS302-868M user guide

SECUMAR SECULUX CFX-II FITTING INSTRUCTION

SECUMAR

SECUMAR SECULUX CFX-II FITTING INSTRUCTION

CNDINGTEK DF703 manual

CNDINGTEK

CNDINGTEK DF703 manual

PCE Americas PCE-191 CB instruction manual

PCE Americas

PCE Americas PCE-191 CB instruction manual

Amprobe RLD-1 user manual

Amprobe

Amprobe RLD-1 user manual

ZyAura ZGw19 operating instructions

ZyAura

ZyAura ZGw19 operating instructions

Weatherdock easyONE-DSC-CL  A10901 user manual

Weatherdock

Weatherdock easyONE-DSC-CL A10901 user manual

WOOX R7046 quick guide

WOOX

WOOX R7046 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.