Quick-Start Instructions
HINT: As you approach the source of the
leak continue adjusting the wheel without
moving the sensor head to a uniform tick
sound until you locate the exact location of
the leak.
IMPORTANT: When replacing the
gooseneck into the clip on the right side,
wrap the gooseneck in a wide circular
manner counter-clockwise around the back
of the instrument. Bending in the opposite
direction may cause damage over the life of
the product.
WARNINGS:
To prevent ignition of ammable or combustible
atmospheres, disconnect power before servicing.
To reduce the risk of ignition of a ammable
atmosphere, batteries must only be changed in
an area known to be nonammable.
Do not mix batteries of different age or type.
This is not a substitute for the
instruction manual. It is for
reference only.
Read and understand the
instruction manual before use.
MADE IN USA
Distributed by:
851 Transport Drive
Valparaiso, IN 46383-8432
Phone: 219 465 2700
Web: www.gasleaksensors.com
SENSIT®CO
SENSIT®GOLD
SENSIT®GOLD 100
SENSIT®GOLD CGI
SENSIT®GOLD G2
SENSIT®HCN
SENSIT®HXG-2
SENSIT®HXG-2d (2dr)
SENSIT®HXG-3 (3P)
SENSIT®P100
SENSIT®P400
SENSIT®PMD
SENSIT®RLD-2
SENSIT®TKX
TRAK-IT®IIIa
ULTRA-TRAC®MJL
GAS-TRAC®
EX 1000
SMART-CAL
TM
SCAL-100
SCAL-NTM
Innovative Detection Solutions
1. Install the batteries by pushing down
the locking tab and sliding the handle
away from the top of the instrument. When
replacing handle be sure the tab is securely
in place and replace the retaining screw.
2. IMPORTANT: CAREFULLY OBSERVE
POLARITY WHEN CHANGING BATTERIES.
Instrument will not function with improperly
installed batteries.
3. Slide the on/off switch to the right to turn on.
4. Allow unit to go through the warm up
sequence in clean air. The tick will sound
and the leak indication light will ash for a
few moments. This requires up to 60 seconds
to fully warm up.
5. Extend the goose neck (the sensor and
cap is at the tip).
6. You are now ready to use the instrument.
You can now enter the area and detect gases.
7. To locate the source of an odor, rotate the
center wheel until there is a uniform ticking
sound. Increased gas concentration will
cause an increase in the speed of the ticking
sound. As you approach the leak rotate the
wheel counter-clockwise to slow the speed.
Rotate clockwise to increase the speed
(indicating lower gas concentrations).
8. When your investigation is complete slide
the switch to the off position.
SENSIT®TKX
QUICK-START INSTRUCTIONS

Other manuals for CO

3

This manual suits for next models

22

Other Sensit Security Sensor manuals

Sensit TKX User manual

Sensit

Sensit TKX User manual

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Sensit RLD-2 User manual

Sensit

Sensit RLD-2 User manual

Sensit TKX User manual

Sensit

Sensit TKX User manual

Sensit HXG-3 User manual

Sensit

Sensit HXG-3 User manual

Sensit PMD2 User manual

Sensit

Sensit PMD2 User manual

Sensit HXG-3P User manual

Sensit

Sensit HXG-3P User manual

Sensit HXG-2d User manual

Sensit

Sensit HXG-2d User manual

Sensit VMD Operating instructions

Sensit

Sensit VMD Operating instructions

Popular Security Sensor manuals by other brands

Bosch RF940E Installation instructions and operators manual

Bosch

Bosch RF940E Installation instructions and operators manual

Sperian Biosystems NXP Reference manual

Sperian

Sperian Biosystems NXP Reference manual

GJD Quad PIR MX20 HT manual

GJD

GJD Quad PIR MX20 HT manual

Nohken VQ32 instruction manual

Nohken

Nohken VQ32 instruction manual

hager TG551A 3 installation manual

hager

hager TG551A 3 installation manual

Milesight WS202-868M user guide

Milesight

Milesight WS202-868M user guide

Phoenix ISL SP-ARC user manual

Phoenix ISL

Phoenix ISL SP-ARC user manual

Greenlee GT-15 instruction manual

Greenlee

Greenlee GT-15 instruction manual

SGB VL Series Documentation

SGB

SGB VL Series Documentation

BRAHMA RE3 quick start guide

BRAHMA

BRAHMA RE3 quick start guide

Macurco OX-6 User instructions

Macurco

Macurco OX-6 User instructions

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Endress+Hauser

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Mustang Survival RESCUE STICK MRD100 owner's manual

Mustang Survival

Mustang Survival RESCUE STICK MRD100 owner's manual

B.E.G. LUXOMAT PD2-M-2C-24V Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD2-M-2C-24V Installation and operating instruction

Hytronik HIR24 Installation and instruction manual

Hytronik

Hytronik HIR24 Installation and instruction manual

Schaller Automation VN115/87plus EX Operation manual

Schaller Automation

Schaller Automation VN115/87plus EX Operation manual

Greenlee 1110 instruction manual

Greenlee

Greenlee 1110 instruction manual

iRay Technology Venu 1012X Calibration guide

iRay Technology

iRay Technology Venu 1012X Calibration guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.