Sharp R-305EW User manual

R-305EW
Intheinterestofuser-safetytheovenshouldberestoredtoitsoriginal
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
fier Assembly, High Voltage Harness etc..)
TABLE OF CONTENTS Page
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................1
MICROWAVE MEASUREMENT PROCEDURE ...................................................................................................2
FOREWORD AND WARNING...............................................................................................................................3
PRODUCT SPECIFICATIONS ..............................................................................................................................4
GENERAL INFORMATION...................................................................................................................................4
OPERATION..........................................................................................................................................................6
TROUBLESHOOTING GUIDE ..............................................................................................................................9
TEST PROCEDURE............................................................................................................................................10
TOUCH CONTROL PANEL.................................................................................................................................18
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE................................................................22
PICTORIAL DIAGRAM ........................................................................................................................................28
POWER UNIT CIRCUIT ......................................................................................................................................29
CPU UNIT CIRCUIT ............................................................................................................................................30
PRINTED WIRING BOARD .................................................................................................................................31
PARTS LIST ........................................................................................................................................................32
PACKING AND ACCESSORIES .........................................................................................................................36
S2104R305EPW/
MICROWAVEOVEN
MODEL R-305EW
SERVICEMANUAL
SHARP CORPORATION This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
POWER
LEVEL TIMER
CLOCK
1 2 3
4 5 6
7 8
09
TO ADJUST QUANTITY TOUCH PAD AGAIN
1 GROUND MEAT
2 STEAKS/CHOPS
3 CHICKEN PIECES
STOP
CLEAR
START
DEFOST
COOK
NO.
LBS.
CUPS.
OZ.
MINUTE PLUS
INSTANT ACTION
COMPU
DEFROST
POPCORN DINNER PLATE CASSEROLE
BAKED POTATOES FRESH VEGETABLE GROUND MEAT
FROZEN ENTREES BEVERAGE ROLLS / MUFFINS

R-305EW
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described
in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave
Measurement Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS
CORPORATION immediately @1-800-237-4277.
If the unit operates with the door open, service person should 1) tell the user not to operate the oven
and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's
Center for Devices and Radiological Health immediately.
ServicepersonnelshouldinformSHARPELECTRONICSCORPORATIONofanycertifiedunitfound
with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit
until the oven has been brought into compliance.

1
R-305EW
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts
may result in a severe, possibly
fatal, electrical shock.
(Example)
HighVoltageCapacitor,HighVoltagePowerTrans-
former,Magnetron,HighVoltageRectifierAssem-
bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconnectthepowersupplycord ¬,andthenremove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
WARNING:RISK OF ELECTRIC SHOCK.
DISCHARGE THE HIGH-VOLTAGE
CAPACITOR BEFORE SERVICING.
The high-voltage capacitor remains charged about 60
secondsaftertheovenhasbeenswitchedoff.Waitfor60
secondsandthenshort-circuittheconnectionofthehigh-
voltagecapacitor(thatistheconnectinglead of the high-
voltage rectifier) against the chassis with the use of an
insulated screwdriver.
Whenever troubleshooting is performed the power supply
mustbedisconnected.Itmay,insomecases,benecessary
to connect the power supply after the outer case has been
removed, in this event,
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power
transformer.
5. Ensure that the leads remain isolated from other
components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power
transformer.
5. Reinstall the outer case (cabinet).
6. Reconnectthe power supply cordaftertheouter case is
installed.
7. Run the oven and check all functions.
After repairing
1. Reconnect all leads removed from components during
testing.
2. Reinstall the outer case (cabinet).
3. Reconnectthe power supply cordaftertheouter case is
installed.
4. Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the
presence of microwave energy within a cavity, place a cup
of cold water on the oven turntable, close the door and set
the power to HIGH and set the microwave timer for two (2)
minutes.When the twominuteshas elapsed (timeratzero)
carefully check that the water is now hot. If the water
remainscoldcarryoutBeforeServicingprocedureandre-
examine the connections to the component being tested.
When all service work is completed and the oven is fully
assembled,themicrowavepoweroutputshouldbechecked
and a microwave leakage test should be carried out.
Don't Touch !
Danger High Voltage

2
R-305EW
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
shouldnotexceed1mW/cm2atanypoint5cmormorefromtheexternalsurfaceoftheoven,measuredpriortoacquisition
byapurchaser,andthereafter(throughtheusefullifeoftheoven),5mW/cm2atany point 5cm or more fromtheexternal
surface of the oven.
2) Safety interlock switches Primary interlock relay and door sensing switch shall prevent microwave radiation emission in
excess of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission
in excess of 5 mW/cm2at any point 5cm or more from the external surface of the oven.
B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for
microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5˚C (68˚F) in the center of the oven cavity.
The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.)
and made of an electrically nonconductive material such as glass or plastic.
Theplacing of thisstandardloadin the ovenisimportantnot only toprotecttheoven, but alsotoinsure that any leakage
is measured accurately.
4) Set the cooking control on Full Power Cooking Mode.
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed,
replace it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasptheprobeofthesurveyinstrumentandholditperpendiculartothegapbetweenthedoorandthebodyoftheoven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on
the meter.
3) Checkforleakageatthedoorscreen,sheetmetalseamsandotheraccessiblepositionswherethecontinuityofthemetal
has been breached (eg., around the switches, indicator, and vents).
Whiletestingforleakagearoundthedoorpullthedoorawayfromthefrontoftheovenasfarasispermittedbytheclosed
latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm2,
and that the secondary interlock switch does turn the oven OFF before any door movement.
NOTE: After servicing, record data on service invoice and microwave leakage report.

3
R-305EW
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
MICROWAVE OVEN
R-305EW
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp.
Service Personnel with Operation and Service Information for the
SHARP MICROWAVE OVEN, R-305EW.
It is recommended that service personnel carefully study the entire
text of this manual so that they will be qualified to render satisfactory
customer service.
Check the interlock switches and the door seal carefully. Special
attention should be given to avoid electrical shock and microwave
radiation hazard.
WARNING
Never operate the oven until the following points are ensured.
(A) The door is tightly closed.
(B) The door brackets and hinges are not defective.
(C) The door packing is not damaged.
(D) The door is not deformed or warped.
(E) There is no other visible damage with the oven.
Servicing and repair work must be carried out only by trained service
personnel. DANGER
Certaininitialpartsareintentionallynotgroundedandpresent
a risk of electrical shock only during servicing. Service
personnel - Do not contact the following parts while the
appliance is energized;
HighVoltageCapacitor,PowerTransformer,Magnetron,High
Voltage Rectifier Assembly, High Voltage Harness;
If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
Allthepartsmarked“*”onpartslistareusedatvoltagesmorethan
250V.
Removal of the outer wrap gives access to voltage above 250V.
Allthepartsmarked“∆”onpartslistmaycauseunduemicrowave
exposure, by themselves, or when they are damaged, loosened
or removed.
PRODUCT DESCRIPTION
GENERAL INFORMATION
OPERATION
TROUBLESHOOTING GUIDE AND
TEST PROCEDURE
TOUCH CONTROL PANEL
COMPONENT REPLACEMENT
AND ADJUSTMENT PROCEDURE
WIRING DIAGRAM
PARTS LIST

4
R-305EW
ITEM DESCRIPTION
Power Requirements 120 Volts / 13 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output 1100 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions Width 20-1/2"
Height 11-7/8"
Depth 17-1/8"
Cooking Cavity Dimensions Width 14-3/4"
Height 8-3/4"
1.2 Cubic Feet Depth 15-3/4"
Control Complement Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
P-HI..................................................Full power throughout the cooking time
P-90 .................................................................... approx. 90% of Full Power
P-80 .................................................................... approx. 80% of Full Power
P-70 .................................................................... approx. 70% of Full Power
P-60 .................................................................... approx. 60% of Full Power
P-50 .................................................................... approx. 50% of Full Power
P-40 .................................................................... approx. 40% of Full Power
P-30 .................................................................... approx. 30% of Full Power
P-20 .................................................................... approx. 20% of Full Power
P-10 .................................................................... approx. 10% of Full Power
P-0 .................................................... No power throughout the cooking time
MINUTE PLUS pad, INSTANT ACTION pads
COMPU DEFROST pad, Number selection pads
POWER LEVEL pad, TIMER/CLOCK pad
STOP/CLEAR pad, START pad
Oven Cavity Light Yes
Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 120 volt 60 Hz, AC only,
15or20amp.fusedelectricalsupply.Itisrecommendedthataseparatecircuitservingonlythisappliancebeprovided.When
installing this appliance, observe all applicable codes and ordinances.
A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord.
Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to

5
R-305EW
contact a qualified electrician and have it replaced with a properly
grounded three-pronged wall receptacle or have a grounding adapter
properly grounded and polarized. If the extension cord must be used, it
should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a
countertopor table whereitcan be pulledonby children ortrippedover
accidentally.
CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE-
MOVE THE ROUND GROUNDING PRONG FROM THIS
PLUG.
3-Pronged Plug Grounded
Receptacle Box
Grounding Pin
3-Pronged Receptacle
OVEN DIAGRAM
1. Door open handle.
Pull to open door.
2. Door latches.
The oven will not operate unless the
door is securely closed.
3. Removable turntable support.
4. Removable turntable.
The turntable will rotate clockwise or
counterclockwise.
5. Oven lamp.
It will light when oven is operating or
door is opened.
6. Oven door with see-through window.
7. Ventilation openings. (Rear)
8. Auto-Touch control panel.
9. Timedisplay:Digitaldisplay,99minutes99seconds.
10.Coupling.
4
3
1
12
7
28
9
6
10 511
11.Wave guide cover.
12.Power supply cord
TOUCH CONTROL PANEL
NOTE:
The directed features are disabled after three minutes
when the oven is not in use. These features are auto-
matically enabled when the door is opened and closed
or the STOP/ CLEAR pad is pressed.
POWER
LEVEL TIMER
CLOCK
1 2 3
4 5 6
7 8
09
TO ADJUST QUANTITY TOUCH PAD AGAIN
1 Ground Meat
2 Steaks/Chops
3 Chicken Pieces
STOP
CLEAR
START
DEFROST
COOK
NO.
LBS.
CUPS.
OZ.
INSTANT ACTION
COMPU
DEFROST
See note.
See note.
POPCORN DINNER PLATE CASSEROLE
BAKED POTATOES FRESH VEGETABLES GROUND MEAT
FROZEN ENTREES BEVERAGE ROLLS / MUFFINS
MINUTE PLUS

6
R-305EW
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
Thefollowingisadescriptionofcomponentfunctionsduring
oven operation.
OFF CONDITION
Closing the door activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (Figure O-1).
1. The display will show flashing "88:88".
2. Tosetanyprogramorsettheclock,youmustfirsttouch
theSTOP/CLEAR pad. Thedisplay will clear,and" : "
will appear.
COOKING CONDITION
Program desired cooking time by touching the NUMBER
pads. Program the power level by touching the POWER
LEVEL pad.
When the START pad is touched, the following operations
occur:
1. The contacts of relays are closed and components
connected to the relays are turned on as follows.
(For details, refer to Figure O-2)
RELAY CONNECTED COMPONENTS
RY-1 oven lamp/turntable motor/fan motor
RY-2 power transformer
2. 120 volts A.C. is supplied to the primary winding of the
power transformer and is converted to about 3.1 volts
A.C. output on the filament winding, and approximately
2370 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron
filamentandtheH.V.windingvoltageissenttoavoltage
doubler circuit.
4. The microwave energy produced by the magnetron is
channelled through the waveguide into the cavity feed-
box, and then into the cavity where the food is placed to
be cooked.
5. Upon completion of the cooking time, the power
transformer, oven lamp, etc. are turned off, and the
generation of microwave energy is stopped. The oven
will revert to the OFF condition.
6. When the door is opened during a cook cycle, the
monitorswitch,doorsensingswitch,secondaryinterlock
switch, relay (RY1) and primary interlock relay are
activated with the following results. The circuits to the
turntable motor, the cooling fan motor, and the high
voltage components are de-energized, the oven lamp
remainson,andthedigitalread-outdisplaysthetimestill
remaining in the cook cycle when the door was opened.
7. Themonitorswitchelectricallymonitors theoperationof
the secondary interlock switch and primary interlock
relay and is mechanically associated with the door so
that it will function in the following sequence.
(1)When the door opens from the closed position, the
primary interlock relay (RY2) and secondary interlock
switch open their contacts. And contacts of the relay
(RY1)remainsclosed.Thenthemonitorswitchcontacts
close.
(2)When the door is closed from the open position, the
monitor switch contacts open first. Then the contacts of
the secondary interlock switch and door sensing switch
close. And contacts of the relay (RY1) open.
Ifthesecondaryinterlockswitch andprimaryinterlockrelay
(RY2)failwiththecontactsclosedwhenthedoorisopened,
the closing of the monitor switch contacts will form a short
circuitthroughthemonitorfuse,secondaryinterlockswitch,
relay (RY1) and primary interlock relay (RY2), causing the
monitor fuse to blow.
POWER LEVEL P-0 TO P-90 COOKING
When Variable Cooking Power is programmed, the 120
voltsA.C.issuppliedtothepowertransformerintermittently
throughthecontactsofrelay(RY-2)whichisoperatedbythe
controlunitwithina32secondtimebase.Microwavepower
operation is as follows:
VARI-MODE ON TIME OFF TIME
P-HI (100% power) 32 sec. 0 sec.
P-90 (approx. 90% power) 30 sec. 2 sec.
P-80 (approx. 80% power) 26 sec. 6 sec.
P-70 (approx. 70% power) 24 sec. 8 sec.
P-60 (approx. 60% power) 22 sec. 10 sec.
P-50 (approx. 50% power) 18 sec. 14 sec.
P-40 (approx. 40% power) 16 sec. 16 sec.
P-30 (approx. 30% power) 12 sec. 20 sec.
P-20 (approx. 20% power) 8 sec. 24 sec.
P-10 (approx. 10% power) 6 sec. 26 sec.
P-0 (approx. 0% power) 0 sec. 32 sec.
Note: The ON/OFF time ratio does not correspond with
the percentage of microwave power, because
approx. 2 seconds are needed for heating of the
magnetron filament.

7
R-305EW
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED
2. CLOCK APPEARS ON DISPLAY
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED
2. COOKING TIME PROGRAMMED
3. VARIABLE COOKING CONTROL "P-HI"
4. "START" PAD TOUCHED
Figure O-2. Oven Schematic-Cooking Condition
NOTE: Indicates components with potential above 250 V.
120V AC
60 Hz
OVEN
LAMP TURN-
TABLE
MOTOR FAN
MOTOR
POWER
TRANSFORMER
CAPACITOR 0.94µF
AC 2200V
MONITOR
SWITCH
RECTIFIER
MAGNETRON
SECONDARY
INTERLOCK
SWITCH
TTM
OL FM
MONITOR
FUSE 20A
A1
A2
N.O.
COM.COM.
N.O.
DOOR
SENSING
SWITCH
(RY-1) (RY-2)
CONTROL UNIT
PRIMARY
INTERLOCK
RELAY
THERMAL
CUT-OUT (OVEN) THERMAL
CUT-OUT (MG.)
SH-B SH-A
GRN
OVEN
LAMP TURN-
TABLE
MOTOR FAN
MOTOR
POWER
TRANSFORMER
MONITOR
SWITCH
RECTIFIER
SECONDARY
INTERLOCK
SWITCH
TTM
OL FM
N.O. N.O.
DOOR
SENSING
SWITCH
SH-B SH-A
(RY-1) (RY-2)
CONTROL UNIT
PRIMARY
INTERLOCK
RELAY
120V AC
60 Hz
GRN
MONITOR
FUSE 20A THERMAL
CUT-OUT (OVEN) THERMAL
CUT-OUT (MG.)
COM.
CAPACITOR 0.94µF
AC 2200V
A1
A2
COM
RECTIFIER
MAGNETRON

8
R-305EW
DESCRIPTION AND FUNCTION OF COMPONENTS
DOOR OPEN MECHANISM
The door is opened by pulling the door. Refer to the Figure
D-1.
Figure D-1. Door Open Mechanis
DOOR SENSING AND SECONDARY INTERLOCK
SWITCHES
The secondary interlock switch is mounted in the lower
positionofthelatchhookandthedoorsensingswitchinthe
primaryinterlocksystemismountedintheupperpositionof
thelatchhook.Theyareactivatedbythelatchheadsonthe
door. When the door is opened, the switches interrupt the
power to all high voltage components. A cook cycle cannot
take place until the door is firmly closed thereby activating
both interlock switches. The primary interlock system con-
sists of the door sensing switch and primary interlock relay
located on the control circuit board.
MONITOR SWITCH
Themonitorswitchisactivated(thecontactsopened)bythe
latch head on the door while the door is closed. The switch
is intended to render the oven inoperative, by means of
blowing the monitor fuse, when the contacts of the primary
interlock relay (RY2) and secondary interlock switch fail to
open when the door is opened.
Functions:
1. When the door is opened, the monitor switch contact
close (to the ON condition) due to their being normally
closed.Atthistimetheprimaryinterlockrelay(RY2)and
secondary interlock switch are in the OFF condition
(contactsopen)duetotheirbeingnormallyopencontact
switches.
2. Asthedoorgoestoaclosedposition,themonitorswitch
contacts are first opened and then the door sensing
switchandthesecondaryinterlockswitchcontactsclose.
(On opening the door, each of these switches operate
inversely.)
3. If the door is opened, and the primary interlock relay
(RY2) and secondary interlock switch contacts fail to
open,themonitorfuseblowssimultaneouslywithclosing
of the monitor switch contacts.
CAUTION: BEFORE REPLACING A BLOWN MONITOR
FUSE TEST THE DOOR SENSING SWITCH,
PRIMARYINTERLOCKRELAY(RY2),RELAY
(RY1), SECONDARY INTERLOCK SWITCH
AND MONITOR SWITCH FOR PROPER OP-
ERATION.(REFERTOCHAPTER"TESTPRO-
CEDURE").
NOTE: MONITOR FUSE AND MONITOR SWITCH ARE
REPLACED AS AN ASSEMBLY.
TURNTABLE MOTOR
The turntable motor rotates the turntable located on the
bottomof the oven cavity,sothatthe foods ontheturntable
cookevenlyduringcooking.Theturntablemayturnineither
direction.
COOLING FAN MOTOR
The cooling fan motor drives a blade which draws external
cool air. This cool air is directed through the air vants
surrounding the magnetron and cools the magnetron. This
air is channelled through the oven cavity to remove steam
and vapors given off from the heating foods. It is then
exhausted through the exhausting air vents at the oven
cavity.
MONITOR FUSE
1. Themonitorfuseblowswhenthecontacts(COM-NO)of
theprimaryinterlockrelay(RY2)andsecondaryinterlock
switchremainclosedwiththe ovendooropenandwhen
the monitor switch closes.
2. If the wire harness or electrical components are short-
circuited, this monitor fuse blows to prevent an electric
shock or fire hazard.
OVEN THERMAL CUT-OUT
Thethermalcut-out,locatedonthetopoftheovencavity,is
designed to prevent damage to the oven by fire. If the food
load is overcooked, by either error in cook time or defect in
the control unit, the thermal cut-out will open.
Under normal operation, the oven thermal cut-out remains
closed. However, when abnormally high temperatures are
reachedwithintheovencavity,theoventhermalcut-outwill
open at 257˚F(125˚C), causing the oven to shut down.
MAGNETRON THERMAL CUT-OUT
Thethermalcut-outlocatednearthemagnetronisdesigned
to prevent damage to the magnetron if an over heated
condition develops in the tube due to cooling fan failure,
obstructed air guide, dirty or blocked air intake, etc.
Undernormaloperation,thethermalcut-outremainsclosed.
However,whenabnormallyhightemperatures arereached
within the magnetron, the thermal cut-out will open at
293˚F(145˚C) causing the oven to shut down.
Latch Hook
Door Sensing
Switch
Latch
Heads
Door
Monitor Switch
Secondary
Interlock Switch

9
R-305EW
TROUBLESHOOTING GUIDE
Nevertouchanypartinthe circuit with yourhandoranuninsulatedtoolwhilethepowersupplyis connected.
Whentroubleshootingthemicrowave oven,itishelpfultofollowtheSequenceofOperationinperformingthechecks.Many
ofthepossiblecausesoftroublewillrequirethataspecifictestbeperformed.Thesetestsaregivenaprocedureletterwhich
will be found in the "Test Procedure "section.
IMPORTANT: If the oven becomes inoperative because of a blown monitor fuse, check the monitor switch, relay (RY1)
primary interlock relay (RY2), door sensing switch and secondary interlock switch before replacing the
monitor fuse. If the monitor fuse is replaced, the monitor switch must also be replaced. Use part FFS-
BA021WRK0 as an assembly.
IMPORTANT: Whenever troubleshooting is performed with the power supply cord disconnected. It may, in some cases,
be necessary to connect the power supply cord after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensurethattheleadsremainisolatedfromothercomponentsandovenchassisbyusinginsulationtape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect all leads removed from components during testing.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all functions.

10
R-305EW
AMAGNETRON ASSEMBLY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
Home fuse or circuit breaker blows
whenpowercordispluggedintowall
receptacle
Monitorfuseblowswhenpowercord
is plugged into wall receptacle.
All letters and indicators do not ap-
pear in display when power cord is
first plugged into wall outlet.
Display does not operate properly
when STOP/CLEAR key is touched.
(Buzzershouldsound and ":" or time
of day should appear in display.)
Oven lamp does not light when door
is opened.
Oven lamp does not go out when
door is closed.
Oven lamp lights but fan motor and
turntable motor do not operate.
Oven does not go into cook cycle
when START pad is touched
Ovenseemstobe operating butlittle
or no heat is produced in oven load.
(Food incompletely cooked or not
cooked at all at end of cook cycle.)
Oven goes into a cook cycle but
extremely uneven heating is pro-
duced in oven load (food).
Oven does not cook properly when
programmed for Cooking Power P-
50 mode. (Operates properly on
Cooking Power P-HI (100%) mode.)
Oven goes into COMPU DEFROST
but food is not defrosted well.
OFF
CONDITION
PROBLEM
CONDITION
SHORT IN POWER CORD
SHORT OR OPENED WIRING
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
THERMAL CUT-OUT
PRIMARY INTERLOCK SYSTEM
SECONDARY INTERLOCK SWITCH
MONITOR SWITCH
MONITOR FUSE
OVEN LAMP OR SOCKET
COOLING FAN MOTOR
TURNTABLE MOTOR
TOUCH CONTROL PANEL
WRONG OPERATION
LOW VOLTAGE
DIRTY OVEN CAVITY
KEY UNIT
RELAY (RY1)
COMPU DEFROST
FOIL PATTERN ON PWB.
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
TEST PROCEDURE
RE RE
ABCDEFFGH
RERE
CK
I
CK CKCK
JKLM
COOKING
CONDITION
CK = Check / RE = Replace
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST

11
R-305EW
BPOWER TRANSFORMER TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the primary input terminals and measure the resistance of the transformer with an
ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of
the primary coil should be less than 1 ohm and the resistance of the high voltage coil should be
approximately 86.3 ohms; the resistance of the filament coil should be less than 1 ohm.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
(HIGHVOLTAGESAREPRESENTATTHE HIGH VOLTAGETERMINAL,SODONOTATTEMPTTO
MEASURE THE FILAMENT AND HIGH VOLTAGE.)
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check
across the magnetron filament leads should indicate less than 1 ohm.
5. Totestforashortedmagnetron,connecttheohmmeterleadsbetweenthemagnetronfilamentleads
and chassis ground. This test should indicate an infinite resistance. If there is little or no resistance
the magnetron is grounded and must be replaced.
6. Reconnect all leads removed from components during testing.
7. Reinstall the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
MICROWAVE OUTPUT POWER
The following test procedure should be carried out with the microwave oven in a fully assembled
condition (outer case fitted).
HIGH VOLTAGES ARE PRESENT DURING THE COOK CYCLE, SO EXTREME CAUTION SHOULD
BE OBSERVED.
Power output of the magnetron can be measured by performing a water temperature rise test. This test
shouldonlybeusedifabovetestsdonotindicateafaultymagnetronandthereisnodefectinthefollowing
componentsorwiring:siliconrectifier,highvoltagecapacitorandpowertransformer.Thistestwillrequire
a 16 ounce (453cc) measuring cup and an accurate mercury thermometer or thermocouple type
temperature tester. For accurate results, the following procedure must be followed carefully:
1. Fillthemeasuringcupwith16oz.(453cc)oftapwaterandmeasurethetemperatureofthewaterwith
a thermometer or thermocouple temperature tester. Stir the thermometer or thermocouple through
the water until the temperature stabilizes. Record the temperature of the water.
2. Place the cup of water in the oven. Operate oven at power P-HI(100%) selecting more than 60
secondscooktime.Allowthewatertoheatfor60seconds,measuringwithastopwatch,secondhand
of a watch or the digital read-out countdown.
3. Remove the cup from the oven and again measure the temperature, making sure to stir the
thermometer or thermocouple through the water until the maximum temperature is recorded.
4. Subtractthecoldwatertemperaturefromthehotwatertemperature.Thenormalresultshouldbe32.1
to59.7˚F(17.9to33.2˚C)riseintemperature.Ifthewatertemperaturesareaccuratelymeasuredand
tested for the required time period the test results will indicate if the magnetron tube has low power
output (low rise in water temperature) which would extend cooking time or high power output (high
risein water temperature)which would reducecookingtime. Because cookingtimecan be adjusted
to compensate for power output, the magnetron tube assembly should be replaced only if the water
temperaturerisetestindicatesapoweroutputwellbeyondthenormallimits.Thetestisonlyaccurate
if the power supply line voltage is 120 volts and the oven cavity is clean.

12
R-305EW
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads
and check for short or open between the terminals using an ohmmeter.
Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate
continuity for a short time and should indicate an open circuit once the capacitor is charged. If the
above is not the case, check the capacitor with an ohmmeter to see if it is shorted between either of
the terminals and case. If it is shorted, replace the capacitor.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
DHIGH VOLTAGE CAPACITOR TEST
E OVEN THERMAL CUT-OUT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the
temperature of the thermal cut-out reaches approximately 257˚F(125˚C).
An open thermal cut-out indicates overheating of the oven, exchange the oven thermal cut-out and
checkinsideofovencavityandforimpropersettingofcookingtimeoroperationofcontrolunit.Check
forrestrictedairflowthroughtheventholesoftheovencavity,especiallythecoolingfanandairguide.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
MAGNETRON THERMAL CUT-OUT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the
temperature of the magnetron reaches approximately 293˚F(145˚C). An open thermal cut-out
indicatesoverheatingofthemagnetron.Checkforrestrictedairflowtothemagnetron,especiallythe
cooling fan air guide.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
C HIGH VOLTAGE RECTIFIER TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the rectifier from the circuit. Using the highest ohm scale of the meter, read the resistance
across the terminals and observe, reverse the leads to the rectifier terminals and observe meter
reading. If a short is indicated in both directions, or if an infinite resistance is read in both directions,
the rectifier is probably defective and should be replaced.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
NOTE:Besure to useanohmmeterthat will supplyaforward bias voltageofmorethan 6.3 volts.

13
R-305EW
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Before performing this test, make sure that the secondary interlock switch and the primary interlock
relayareoperatingproperly,accordingtotheaboveSwitchTestProcedure.Disconnectthewirelead
fromthe monitor switch(COM)terminal.Check the monitorswitchoperationby using theohmmeter
asfollows.Whenthedoorisopen,themetershouldindicateaclosedcircuit.Whenthemonitorswitch
actuatoris pushed byascrewdriver through thelowerlatchhole on thefrontplateof the ovencavity
withthedooropened(inthisconditiontheplungerofthemonitorswitchispushedin),themetershould
indicate an open circuit. If improper operation is indicated, the switch may be defective. After testing
the monitor switch, reconnect the wire lead to the monitor switch (COM) terminal and check the
continuity of the monitor circuit.
CAUTION: IFTHETHERMALCUT-OUTINDICATESANOPENCIRCUITATROOMTEMPERATURE,
REPLACE THERMAL CUT-OUT.
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolatetheswitchandconnecttheohmmetertothecommon(COM.)andnormallyopen(NO)terminal
of the switch. The meter should indicate an open circuit with the door open and a closed circuit with
the door closed. If improper operation is indicated, replace the secondary interlock switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
PRIMARY INTERLOCK SYSTEM TEST
DOOR SENSING SWITCH
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolatetheswitchandconnecttheohmmetertothecommon(COM.)andnormallyopen(NO)terminal
of the switch. The meter should indicate an open circuit with the door open and a closed circuit with
the door closed. If improper operation is indicated, replace the door sensing switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the cooling
fan, turntable and oven light will be activated by RY1.
PRIMARY INTERLOCK RELAY (RY2)
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay. Check the
stateoftherelaycontactsusingaohmmeter.Therelaycontactsshouldbeopen.Iftherelaycontacts
are closed, replace the circuit board entirely or the relay itself.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
F SECONDARY INTERLOCK SWITCH TEST
GMONITOR SWITCH TEST

14
R-305EW
H BLOWN MONITOR FUSE TEST
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary
interlockswitchandmonitorswitchaccordingtothe"TESTPROCEDURE"forthoseswitchesbefore
replacing the blown monitor fuse.
CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK
RELAY,SECONDARYINTERLOCKSWITCH,DOORSENSINGSWITCHANDMONITOR
SWITCH FOR PROPER OPERATION.
If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must
be replaced with "monitor fuse and monitor switch assembly" part number FFS-BA021WRK0, even
ifthemonitor switch operates normally. Themonitorfuseandmonitorswitch assembly is comprised
of a 20 ampere fuse and switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter
andohmmeter.Inthisservicemanual,thetouchcontrolpanelassemblyisdividedintotwounits,Control
Unit and Key Unit, and also the Control Unit is divided into two units, CPU Unit and Power Unit, and
troubleshooting by unit replacement is described according to the symptoms indicated.
Before testing,
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
1. Key Unit.
NOTE ;
1) Check Key unit ribbon connection before replacement.
2) Reconnect all leads removed from components during testing.
3) Re-install the outer case (cabinet).
4) Reconnect the power supply cord after the outer case is installed.
5) Run the oven and check all functions.
The following symptoms indicate a defective key unit.
a) When touching the pads, a certain pad produces no signal at all.
b) When touching a number pad, two figures or more are displayed.
I TOUCH CONTROL PANEL ASSEMBLY TEST
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all
functions.
Secondary
Interlock Switch
Monitor Switch
Screw Driver
Ohmmeter
RED WHT

15
R-305EW
c) When touching the pads, sometimes a pad produces no signal.
If the Key unit is defective.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Replace the Key unit.
5) Reconnect all leads removed from components during testing.
6) Re-install the outer case (cabinet).
7) Reconnect the power supply cord after the outer case is installed.
8) Run the oven and check all functions.
2. Control Unit
The following symptoms indicate a defective control unit. Before replacing the control unit, perform
the Key unit test (Procedure J) to determine if control unit is faulty.
2-1 In connection with pads.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2-2 In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light.
d) The corresponding segments of all digits do not light up; or they continue to light up.
e) Wrong figure appears.
f) A certain group of indicators do not light up.
g) The figure of all digits flicker.
2-3 Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Clock does not operate properly.
c) Cooking is not possible.
When testing is completed,
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Reconnect all leads removed from components during testing.
5) Re-install the outer case (cabinet).
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
J KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
ismakinggoodcontact,verifythatthedoorsensingswitch(stopswitch)operatesproperly;thatisthe
contacts are closed when the door is closed and open when the door is open. If the door sensing
switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control
unitandmake sure the door sensingswitchisclosed(eitherclose the door orshortthedoorsensing
switch connector). Use the Key unit matrix indicated on the control panel schematic and place a
jumperwirebetweenthepinsthatcorrespondtotheSTOP/CLEARpadmakingmomentarycontact.
If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the
control unit does not respond, it is faulty and must be replaced. If a specific pad does not respond,
the above method may be used (after clearing the control unit) to determine if the control unit or key
pad is at fault.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.

16
R-305EW
WARNING : The oven should be fully assembled before following procedure.
(1)Place one cup of water in the center of the turntable tray in the oven cavity.
(2)Close the door, touch the " COMPU DEFROST " pad twice.
(3)Touch the Number pad " 5 " and then touch the " START " pad.
(4)The oven is in Compu Defrost cooking condition.
(5)The oven will operate as follows.
MENU 1ST STAGE 2ND STAGE
Steaks/Chops LEVEL TIME LEVEL TIME
0.5lb 70% 1min.10sec. 40% 30sec.
(6)If improper operation is indicated, the control unit is probably defective and should be checked.
8. Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensurethattheseleadsremainisolatedfromothercomponentsandovenchassisbyusinginsulation
tape.
6. After that procedure, re-connect the power supply cord.
7. RemovetheoutercaseandcheckvoltagebetweenPinNo.1ofthe2pinconnector(A)andthenormal
open terminal of the relay RY1 on the control unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated..........................Defective relay.
DC. voltage not indicated....................Check diode which is connected to the relay coil. If diode
is good, control unit is defective.
RELAY SYMBOL OPERATIONAL VOLTAGE CONNECTED COMPONENTS
RY1 Approx. -12.2V D.C. Oven lamp / Turntable motor / Cooling fan motor
RY2 Approx. -11.1V D.C. Power transformer
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. Discharge high voltage capacitor.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all functions.
KRELAY TEST
LCOMPU DEFROST TEST
54321
09876
START
BEVERAGE
POPCORN
CASSEROLE
POWER
LEVEL DINNER
PLATE
GROUND
MEAT
FROZEN
ENTREES
COMPU
DEFROST
MINUTE
PLUS
FRESH
VEGETABLES
ROLLS /
MUFFINS
BAKED
POTATOES
STOP
CLEAR
TIMER
CLOCK
G 8
G 9
G10
G11
G12
G13
G14
G 7 G 6 G 5 G 4 G 3 G 2 G 1

17
R-305EW
TEST PROCEDURES
PROCEDURE
LETTER COMPONENT TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
STEPS OCCURRENCE CAUSE OR CORRECTION
1 Only pattern at "a" is broken. *Insert jumper wire J1 and solder.
2 Pattern at "a" and "b" are broken. *Insert the coil RCILF2003YAZZ between "c" and "d".
5) Make a visual inspection of the varistor. Check
forburneddamageandexaminethetransformer
with a tester for the presence of layer short-
circuit (check the primary coil resistance which
is approximately 540Ω±20%). If any abnormal
conditionisdetected,replacethedefectiveparts.
6) Reconnect all leads removed from components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator does not light up after above check and
repairs are finished.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS OCCURRENCE CAUSE OR CORRECTION
The rated AC voltage is not present between
1 Pin No. 1 of the 2-pin connector (A) and the Check supply voltage and oven power cord.
normal open terminal of the relay RY1.
2The rated AC voltage is present at primary Low voltage transformer or secondary circuit defective.
side of low voltage transformer. Check and repair.
8) Disconnect the power supply cord, and then remove outer case.
9) Open the door and block it open.
10) Discharge high voltage capacitor.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
M FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
RY1
a
b
d
c
XA
VRS1
(J1)

18
R-305EW
3) Power Source Circuit
This circuit generates voltages necessary in the control
unit from the AC line voltage.
Inaddition,thesynchronizingsignalisavailableinorder
to compose a basic standard time in the clock circuit.
Symbol Voltage Application
VC -5V LSI(IC1)
4) Relay Circuit
A circuit to drive the magnetron, fan motor, turntable
motor and light the oven lamp.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audiblesounds(keytouchsoundandcompletionsound).
6) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit.
It accompanies a very small error because it works on
commercial frequency.
7) Door Sensing Switch
A switch to “tell” the LSI if the door is open or closed.
8) Back Light Circuit
A circuit to drive the back light (Light emitting diodes
LD1- LD4).
1-2 VL2-VL1 IN Power source voltage input terminal.
Standard voltage for LCD.
3-6 AN7-AN4 IN Terminal to change cooking input according to the Model.
ByusingtheA/DconvertercontainedintheLSI,DCvoltageinaccordancewiththeModel
in operation is applied to set up its cooking constant.
7 P63 OUT Terminal not used.
8 AN2 IN Input terminal to judge the model.
Connected to GND through the pull-down resistor R78.
9 AN1 IN To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
10 AN0 IN Input terminal to judge the model.
The signal out of P22 will be input into AN0 through G3 line on key matrix. The LSI will
judge the model by this signal.
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1)Key Unit
(2)ControlUnit(TheControlUnitconsistsofPowerUnitand
CPU Unit).
The principal functions of these units and the signals com-
municated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
theLSIaresenttothekeyunitthroughP20,P21, P22,P23,
P24, P25, P26 and P27.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through P41, P43,
P44, P45 and AN0 to perform the function that was re-
quested.
Control Unit
Control unit consists of LSI, ACL circuit, indicator circuit,
power source circuit, relay circuit, buzzer circuit, synchro-
nizing signal circuit and back light circuit.
1) ACL
ThiscircuitgeneratesasignalwhichresetstheLSItothe
initial state when power is supplied.
2) Indicator Circuit
This circuit consists of 22 segments and 3 common
electrodes using a Liquid Crystal Display.
LSI(IXA096DR)
The I/O signal of the LSI(IXA096DR) is detailed in the following table.
Pin No. Signal I/O Description
Table of contents
Other Sharp Microwave Oven manuals

Sharp
Sharp R-230F User manual

Sharp
Sharp R-9360 User manual

Sharp
Sharp R-4H10 User manual

Sharp
Sharp R-793M Instruction Manual

Sharp
Sharp R-300BW User manual

Sharp
Sharp R-380H Instruction Manual

Sharp
Sharp R-622STWE User manual

Sharp
Sharp EBR-9900W User manual

Sharp
Sharp YC-AS201 User manual

Sharp
Sharp Carousel R-90GCS User manual

Sharp
Sharp Carousel R-307E User manual

Sharp
Sharp R-292 User manual

Sharp
Sharp R-308JS User manual

Sharp
Sharp R-410H User manual

Sharp
Sharp R-8470 User manual

Sharp
Sharp R-93ST-A Instruction Manual

Sharp
Sharp R-370EZ User manual

Sharp
Sharp Carousel R-310H User manual

Sharp
Sharp R-230KK User manual

Sharp
Sharp R-508CK User manual