Introduction
About The ShoreGear 220T1A
The ShoreGear 220T1A Voice Switch connects internal extensions or IP phones to a
central office (CO) digital trunk line.
The switch provides connectivity through:
Two RJ-45 LAN connectors
One RJ-45 T1 port for connecting the switch to a telephone company line
One RJ-45 T1 monitor port for connecting test equipment
One RJ-21X port (male) for connecting the switch to a telephone company punch-
down block, patch panel, or 12-port harmonica connector
One DB-9 (female), RS-232C maintenance port (19200 bps, 8 bits, no parity, 1 stop
bit, no handshake) for serial communications
One audio input port (3.5 mm stereo) for connecting to a music-on-hold source
One audio output port (3.5 mm stereo) for connecting to a corporate paging system or
night bell
•
•
•
•
•
•
•
The ShoreGear 220T1A Voice Switch package contains:
ShoreGear 220T1A Voice Switch
Power cord
Stick-on feet for surface installation
Mounting Ears – attachable installation brackets
Cable Retainer for the Telco cable (metal bracket with a Velcro strap)
•
•
•
•
•
Installation and Servicing Connections
Mounting the ShoreGear Voice Switch on a Flat Surface
If you plan to mount the switch on a flat surface, first attach the provided rubber feet
to the bottom corners of the device. (You can stack up to three switches in a surface
installation.)
Installing the ShoreGear 220T1A in a 19-inch Rack
The SG-220T1A is placed in a 19-inch rack only by mounting a ShoreGear Dual Tray into
the rack, then installing the SG-220T1A into the Tray. You can install the SG-220T1A on
the left or right side of the tray.
Refer to the Quick Install Guide for the ShoreGear Dual Tray for Tray installation
instructions and information on using the tray.
Installation Location Requirements
To ensure optimum operating conditions for the SG-220T1A voice switch, verify the
operating environment is adequately ventilated, free of gas or airborne particles, and
isolated from electrical noise.
Installation Equipment
To install the switch, you need the following equipment:
AC surge protector for the power connection
RJ-45 cables for connecting the switch to the local area network and telco lines
Music-on-hold source with a standard mini-headphone Y-adapter (optional)
Permanent earthing connector for grounding the device
RJ-21 telephone cable (female on end connected to ShoreGear voice switch) for analog
port connections
RJ-21 to RJ-11 patch panel for connecting telephones and trunk lines
#1 Phillips screwdriver
•
•
•
•
•
•
•
After setting up the network connections and configuring the ShoreGear
220T1A Voice Switch for operations, you can connect your T1 line to
the switch.
Use an RJ-45 T1 cable to connect your T1 line to the Telco port.
Connecting a T1 Line
Powering on the ShoreGear Voice Switch
After connecting the switch to the network, power on the device by connecting it to an
AC power source.
Plug an AC surge protector (not provided) into a grounded AC power source.
Plug one end of the provided power cord into the receptacle on the back of the switch,
then plug the other end into the AC surge protector.
The power LED flashes momentarily, and remains lit.
If LED is not lit, verify the power cord is plugged into the switch and power source.
If the LED continues flashing, there is an internal error. Unplug the switch to power it
off, then power it back on. Refer to the “Configuring Switches” chapter in the ShoreTel
Administration Guide for information on flash patterns, or contact the ShoreTel
Support Services at http://www.shoretel.com.
The LAN ports auto-sense the network transport rate. When the network connection is
established, the network LED indicates a transport rate of 10 Mbps or 100 Mbps, and
whether the switch is receiving and transmitting data.
1.
2.
•
•
Default
Switch
Audio Output Port
(night bell)
Power
LED Network
LEDs
LAN 2
Connector
RS-232C
Maintentance
Port
Status
LED
Audio Input Port
(music on hold)
Network
LEDs
T1 LEDs
T1 LEDs
LAN 1
Connector
T1 Monitor
Port
T1 Telco
Port
RJ-21X
Telco Port
Once the SG-220T1A Voice Switch is secured to a rack or surface-
mounted, you can connect it to the data network. Use an RJ-45 Ethernet
cable to connect one or both of the LAN ports to the network subnet.
While both ports can detect and respond to link status, the switch uses
only one LAN port at a time.
Connecting the ShoreGear Voice Switch to the Network
Optional Connections
After connecting the voice switch to the LAN, you can make optional
connections, including input from a music-on-hold source or output to
your internal paging system.
Connect a music-on-hold source (CD player or other audio source) to
the audio input port.
Connect your site’s paging system to the audio output port.
1.
2.
German: Das ShoreGear Voice-Schaltgerät auf einer ebenen
Oberfläche montieren
Wenn Sie planen, das Gerät auf einer ebenen Oberfläche zu montieren, befestigen Sie
zunächst die mitgelieferten Gummifüße an den unteren Ecken des Geräts. (Bei einer
Oberflächeninstallation können Sie bis zu drei Schaltgeräte übereinander stapeln.)
Attaching an Earthing Connector
To meet electrical safety requirements for proper grounding, you must connect a
permanent earthing protector between the ShoreGear voice switch and the wiring system
ground.
Connect a ground wire (#14 AWG wire or larger) to the screw on the back of the unit
and to the right of the product label.
Connect the other end of the ground wire to the wiring system ground.
CAUTION: Always connect the permanent earthing connector before attempting to connect
the switch to a LAN segment and telecommunication lines.
1.
2.
German: Einen Erdungsleiter anschließen
Um den elektrischen Sicherheitsanforderungen für eine korrekte Erdung nachzukommen,
müssen Sie einen permanenten Erdungsschutz zwischen dem ShoreGear-Gerät und der
Erde des Kabelsystems installieren.
Schließen Sie ein Erdungskabel (Nr. 14 AWG oder größer) an die Schraube an der
Rückseite des Geräts an, die sich rechts neben dem Produktetikett befindet.
Schließen Sie das andere Ende des Erdungskabels an die Erde des Kabelsystems an.
VORSICHT: Schließen Sie immer zuerst den permanenten Erdungsschutz an, bevor Sie ver-
suchen, das Gerät an ein LAN-Segment und Telekommunikationsleitungen anzuschließen.
1.
2.
Connecting Trunk and Telephone Lines
Use the provided cable retainer to connect the voice switch to the
telephone company’s punch-down block or patch panel.
Use a #1 Phillips screwdriver to remove the two screws on either side
of the RJ-21X port, then place the retainer on the port and re-attach
the screws.
1.
Plug the Telco cable into the port, then pull the Velcro strap tightly
around the cable connector and fasten it.
Connect the other end of the Telco cable to the punch-down block or
patch panel.
2.
3.
CAUTION: To reduce risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed
or CSA Certified Telecommunication Line Cord
For detailed information on switch port and trunk configuration, see the “Configuring
Switches” and “Configuring Trunks” sections in the ShoreTel Administration Guide.
Servicing Procedures
WARNING: The SG-220T1A contains no internal field serviceable parts. Return the
equipment to ShoreTel for any required service procedures.
CAUTION: Internal fuses should be serviced only by qualified ShoreTel personnel. If
internal fuses are blown and require replacement, return the SG-220T1A to ShoreTel for
service.
Configuration & Specifications Switch Status
Quick Install Guide
ShoreGear 220T1A Voice Switch
Copyright © 2007 ShoreTel. All rights reserved. ShoreTel, the ShoreTel logo, ShoreGear,
ShoreWare, and ShorePhone are trademarks of ShoreTel, Inc. in the United States and/or other
countries. All specifications are subject to change without notice. This product is covered by one or
more of the following patents: United States Patent 6,996,059,United States Patent 7,003,091, and
United States Patent 7,167,486. ShoreTel, Inc. All rights reserved.
PN 850-1114-01
960 Stewart Drive Sunnyvale, California 94085
Phone: +1.408.331.3300 OR +1.800.425.9385 Fax: +1.408.331.3333 www.shoretel.com
Power LED
The power LED indicates the operating status of the switch.
Light Description
Steady The switch is powered on, and the internal software is running.
Flashing Two flashes indicates a failed internal self-test (i.e. hardware failure). Refer to “Configuring
Switches” in the ShoreTel Administration Guide for details on other flash patterns.
Off The switch is not powered on, or the software is not running.
Status LED
The status LED provides voice switch activity information.
Color Activity Description
Off No ports are assigned
Green Steady No ports are handling active calls
Green Flashing-Fast At least one port is handling an active call.
Yellow Steady No ports are handling active calls and at least one port is out of service.
Yellow Flashing-Slow The switch is not connected (or has lost connection) to a ShoreTel server.
Yellow Flashing-Fast At least one port is handling an active call and at least one port is out of
service.
Network LEDs
Each LAN connector provides two LEDs (Link/Act and 100) that indicates the activity
and communication speed of the connected network.
LED Color/State Description
Link/Act Off This switch cannot detect an Ethernet network.
Link/Act Green-Steady This switch is connected to an Ethernet network.
Link/Act Green-Flashing This switch detects network data traffic.
100 Off Network interface is operating at 10 Mbps.
100 Green Network interface is operating at 100 Mbps.
T1 LEDs
The T1 LEDs indicate line coding, network framing, and loopback status.
LED Color/State Description
Line coding Green The AMI or B8ZS line coding signal is good.
Line coding Yellow This switch is receiving bipolar violations (BPV) at one-second intervals.
Line coding Red A loss of signal (LOS) has occurred.
Line coding Off The switch has no power.
Framing Green The T1 signal is in frame (synchronized)
Framing Yellow The CO has sent a yellow alarm.
Framing Yellow-Flashing The frame-bit error rate has exceeded its limits
Framing Red T1 signal is out-of-frame (OOF) and cannot be framed to the Extended
Superframe (ESF) or D4 format.
Framing Off This switch has no power.
LC/Framing Red-Flashing Loopback is enabled. (Loopback can be set from Shoreline Director or
at the CO).
Network Configuration
Once the ShoreGear voice switch is installed and powered on, it must be configured for
network operations. A voice switch gets a network configuration by assignment from a
DHCP or BOOTP server, or directly from an administrator console (see procedure below).
For more information on setting up a switch for automatic configuration by a DHCP or
BOOTP server, see the ShoreTel Planning and Installation Guide.
Configuring the Voice Switch from a Console
Use a straight-through serial cable, DB9 male to DB9 female, to connect the switch to a
console PC.
On the PC or laptop, start a terminal emulation program and connect to the voice
switch using these serial communication settings: 19200 bps, 8 data bits, no parity,
one stop bit, no handshake.
At the ShoreTel login prompt, press ENTER to display the Switch Options menu.
Type 3 and press ENTER to display a menu of configuration options.
Choose Menu Options and follow the onscreen instructions for setting network
parameters, including IP address, subnet mask, and gateway.
1.
2.
3.
4.
5.
Specifications
Feature Specification
Dimensions 1.69 x 8.39 x 14.28 inches (43 x 213 x 378)
Weight 5.3 lb (2.4 kg)
Input voltage 100-240 VAC, 50-60 Hz
Power consumption 1A max.
Humidity 0-90% relative humidity (non-condensing)
Operating temperature 0-50˚C
ShoreGear 220T1A Voice Switch RJ-21X Port Pinout
An RJ-21 telephone cable, wired straight through, allows the ShoreGear 220T1A Voice
Switch to connect to a standard 12-port patch panel or 12-port harmonica block. When
connecting to a 24-port patch panel, the voice switch’s six analog extension ports map to
ports 1 and 3 and ports 17, 19, 21, and 23 on the patch panel. The Power Fail Transfer
Unit provides an electrical connection between trunk channel 1 and the extension on
channel 12.
Pin No. 12345678910111213141516171819202122232425
Port No. 12 9101112
X
Port Type TT EEEE
X
Pin No. 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Pin pairs Assignment
1,26 3,28 Two loop start ports (T) for trunks.
17,42 19,44 21,46 23,48 Four configurable ports (E) for telephones or DID trunks.

Other SHORE TEL Switch manuals

SHORE TEL ST50A User manual

SHORE TEL

SHORE TEL ST50A User manual

SHORE TEL Extreme Summit x440 Series User manual

SHORE TEL

SHORE TEL Extreme Summit x440 Series User manual

SHORE TEL ShoreGear 90BRI User manual

SHORE TEL

SHORE TEL ShoreGear 90BRI User manual

SHORE TEL ST100DA User manual

SHORE TEL

SHORE TEL ST100DA User manual

SHORE TEL SG-120 User manual

SHORE TEL

SHORE TEL SG-120 User manual

SHORE TEL ShoreGear-T1 User manual

SHORE TEL

SHORE TEL ShoreGear-T1 User manual

SHORE TEL ShoreGear 90BRI User manual

SHORE TEL

SHORE TEL ShoreGear 90BRI User manual

SHORE TEL SG-220T1 User manual

SHORE TEL

SHORE TEL SG-220T1 User manual

SHORE TEL ShoreGear 90BRIV User manual

SHORE TEL

SHORE TEL ShoreGear 90BRIV User manual

SHORE TEL ShoreGear-60/12 User manual

SHORE TEL

SHORE TEL ShoreGear-60/12 User manual

SHORE TEL ST1D User manual

SHORE TEL

SHORE TEL ST1D User manual

SHORE TEL 200 User manual

SHORE TEL

SHORE TEL 200 User manual

SHORE TEL ShoreGear 30 User manual

SHORE TEL

SHORE TEL ShoreGear 30 User manual

Popular Switch manuals by other brands

Elastic Networks BitStorm L3S-T user manual

Elastic Networks

Elastic Networks BitStorm L3S-T user manual

Avocent DSR Series DSR1010 release note

Avocent

Avocent DSR Series DSR1010 release note

Conrad 98 90 50 operating instructions

Conrad

Conrad 98 90 50 operating instructions

Juniper EX4550 Hardware guide

Juniper

Juniper EX4550 Hardware guide

Moxa Technologies EtherDevice EDS-P510 Series Hardware installation guide

Moxa Technologies

Moxa Technologies EtherDevice EDS-P510 Series Hardware installation guide

Freedom9 freeView IP 100 user manual

Freedom9

Freedom9 freeView IP 100 user manual

ROSSMA IIOT-AMS Tilt Counter Operation manual

ROSSMA

ROSSMA IIOT-AMS Tilt Counter Operation manual

IQlife Touch Wall Switch installation manual

IQlife

IQlife Touch Wall Switch installation manual

TRENDnet TK-215i user guide

TRENDnet

TRENDnet TK-215i user guide

D-Link DGS-1520-28MP Quick installation guide

D-Link

D-Link DGS-1520-28MP Quick installation guide

D-Link DGS-1024C Quick installation guide

D-Link

D-Link DGS-1024C Quick installation guide

Ampete 8FX owner's manual

Ampete

Ampete 8FX owner's manual

Conrad 91 79 13 operating instructions

Conrad

Conrad 91 79 13 operating instructions

Panasonic KX-T206E user manual

Panasonic

Panasonic KX-T206E user manual

SeaLevel HUB4SSBA user manual

SeaLevel

SeaLevel HUB4SSBA user manual

Omnitron Systems OmniConverter 10G/Sx 6 user manual

Omnitron Systems

Omnitron Systems OmniConverter 10G/Sx 6 user manual

Radio Shack 1500474 user guide

Radio Shack

Radio Shack 1500474 user guide

JUKI 0040113520 Wiring instructions

JUKI

JUKI 0040113520 Wiring instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.