CODE 080860-011
Dry Battery Unit DB-10N Operation Manual
Thank you for buying the DB-10N Dry Battery Unit exclusively
for the MP-ΣN / MP-ΣNⅡSeries. Before using the DB-10N,
be sure to thoroughly read this manual to ensure correct use.
Also, keep this manual in a safe place so that it can be
referred to whenever necessary.
- 1 -
18.12.19H (04)
Safety Precautions
The precautionary information that appears in this manual is for
ensuring that the product is used safely and for preventing injury to
you and other people and damage to equipment.
It is all important for ensuring safety and so be sure to read it
thoroughly before using the product and observe it during use.
Warning Indications
DANGER:Impending danger is expected
that might result in death or
serious injury.
WARNING:There is an expected risk that
might result in death or serious
injury.
CAUTION:There is an expected risk of
moderate injury or property
damage.
- 2 -
DANGER
Misuse might cause electric shock, generation of heat,
fire, or rupturing, which will result in burns, serious
injury or blindness.
• Do not leave in a location that heats up, for example, on
dashboards or near windows in cars, in the direct sunlight,
inside cars in the hot sun or near stoves or other heat
sources.
• Do not leave near stoves or other heat sources.
• Do not immerse the DB-10N in water or allow it to get wet.
• Do not short-circuit the electrodes with wire or other metal
objects.
• Do not throw or subject the DB-10N to impact, such as
dropping it from high places.
• Do not directly solder the terminals.
• Do not put inside microwave ovens or other high-voltage
containers.
• Do not allow infants, animals or pets to touch the DB -10N.
Licking the DB -10N or putting it in your mouth or biting it is
dangerous.
• Do not place heavy objects on the DB-10N.
• Insert the dry cells making sure that the polarities (+ -) of the
electrodes are oriented correctly.
- 3 -
WARNING
Misuse might cause electric shock, generation of heat,
fire, or rupturing, which will result in burns, injury or
blindness.
• Do not place flammable objects on or cover the DB-10N during
use.
• Do not dismantle or modify this product.
• Do not use the DB-10N in environments subject to flammable
gases or corrosive gases such as salt spray.
• When not using the DB-10N for a long time, remove the dry
cells.
• Do not mix used and new dry cells together.
• Before replacing the dry cells, remove the DB-10N from the
MP-ΣN / MP-ΣNⅡSeries or turn the MP-ΣN / MP-ΣNⅡSeries
OFF.
- 4 -
CAUTION
Misuse might cause moderate injury or physical damage.
• When disposing of the DB-10N, remove the dry cells inside, and
dispose of it in accordance with the disposal laws and
regulations of your local governing body. Also dispose of dry cells
in accordance with these laws and regulations.
• If you notice abnormal odors, heat generation, deformation, or
anything different or unusual from up till now during use and
storage of the DB-10N, immediately stop use and contact your
Sibata agent.
• Immediately move the DB-10N away from flames if the dry cells
leak or you notice an abnormal odor.
• This product assumes use of alkaline AA (LR6) dry cells. Since the
cells used are rechargeable dry cells, other dry cells sometimes
cannot be used since their dimensions differ from those of alkaline
dry cells. Also, OXYRIDE and EVOLTA * cells cannot be used
since their voltages, dimensions and shape are different. Some AA
(LR6) alkaline batteries are slightly larger than others and might be
difficult or impossible to insert. If the size is not correct, please use
another AA battery.
* OXYRIDE and EVOLTA are registered trademarks of Panasonic.
• Other precautions follow the specifications and instruction
manual for the dry cells.
• When carrying the DB-10N, be sure to put it in its box as far as
possible. - 5 -
Features
zThis is the exclusive dry battery unit for the MP-ΣN / MP-ΣNⅡ
Series.
zThe dry cells can be replaced with the unit attached to the
MP-ΣN / MP-ΣNⅡSeries.
* Be sure to turn the MP-ΣN / MP-ΣNⅡSeries OFF before
replacing the dry cells.
zEight alkaline AA dry cells are used.
- 6 -
Front View
- 7 -
Handling Method
Attach the DB-10N to the MP-ΣN / MP-ΣNⅡSeries as shown in
the figure.
- 8 -
How to Replace the Dry Cells
(1) Open the cover, and remove the dry cell holder inside.
(2) Swap the dry cells with new ones. (Dry cells are sold
separately.)
Use alkaline AA dry cells (LR6). Use of other cells might
prevent the intended performance from being achieved. Also,
since the cells used are rechargeable dry cells, other dry
cells sometimes cannot be used since their dimensions differ
from those of alkaline dry cells.
- 9 -
Some AA (LR6) alkaline batteries are slightly larger than others
and might be difficult or impossible to insert. If you use force
and insert a battery that is not the correct size, it may be
impossible to remove or it may make poor contact and not work.
If the size is not correct, please use another AA battery.
(3) Insert the dry cell holder into the DB-10N, and make sure that
the electrodes inside are firmly contacting each other.
- 10 -
(4) Close the cover firmly.
Specifications
Item code 080860-011
Model DB-10N
Recommended dry cells 8 ×alkaline AA (LR6)
Operating temperature / 0 to 40 °C
humidity range 10 to 90%rh (no condensation)
External dimensions 45 (W) ×67 (D) ×93 (H) mm
Weight Approx. 0.1 kg (excluding weight of dry cells)
- 11 -
Cross-section view
Electrodes
Insert
straight.
"Click"
Electrodes
Connect to the
MP-ΣN / MP-ΣNⅡ
Series. Electrode
specifications
Mounting position
mark
Body side
For details, refer to the
MP-ΣN / MP-ΣNⅡSeries
O
p
eration Manual.
Dry cell
holder

Popular Batteries Pack manuals by other brands

Belkin TUNEPOWER F8E490EA Guía De Instalación Rápida

Belkin

Belkin TUNEPOWER F8E490EA Guía De Instalación Rápida

SunStone Power SLPO12-100N user manual

SunStone Power

SunStone Power SLPO12-100N user manual

Fluke BP190 instruction sheet

Fluke

Fluke BP190 instruction sheet

NEC VERSA FX installation guide

NEC

NEC VERSA FX installation guide

Dynex DX-922 Quick setup guide

Dynex

Dynex DX-922 Quick setup guide

UPOWER Ecoline NauticBattery NA-12Li300BL quick start guide

UPOWER Ecoline

UPOWER Ecoline NauticBattery NA-12Li300BL quick start guide

Aeson Power TL-LFP Series Installation and operation manual

Aeson Power

Aeson Power TL-LFP Series Installation and operation manual

xtpower MP-10000 Technical Description, User's Guide

xtpower

xtpower MP-10000 Technical Description, User's Guide

JVC BN-VG107U Getting started

JVC

JVC BN-VG107U Getting started

VEGA POWER Power Cell PCW050050N Instruction and operation manual

VEGA POWER

VEGA POWER Power Cell PCW050050N Instruction and operation manual

Growatt APX 5.0-30.0P-S0 user manual

Growatt

Growatt APX 5.0-30.0P-S0 user manual

Saft STM 5-100 Technical Manual Installation, Operation and Maintenance

Saft

Saft STM 5-100 Technical Manual Installation, Operation and Maintenance

Hubbell DualLite PLD12MI installation instructions

Hubbell

Hubbell DualLite PLD12MI installation instructions

1st-rc BUFFER V4.8 owner's manual

1st-rc

1st-rc BUFFER V4.8 owner's manual

Master Battery UPOWER Ecoline UE-24Li25 manual

Master Battery

Master Battery UPOWER Ecoline UE-24Li25 manual

Aegis ABL-12020P user manual

Aegis

Aegis ABL-12020P user manual

Richmond GTR205 quick start guide

Richmond

Richmond GTR205 quick start guide

BYD Battery-Box L 3.5(AU) user manual

BYD

BYD Battery-Box L 3.5(AU) user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.