Siemens ADE5300 User manual

Siemens AB
Security Product
SiPass integrated
ADE5300
Eight Reader Interface
Installation Manual

Liefermöglichkeiten und technische Änderungen vorbehalten.
Data and design subject to change without notice. / Supply subject to availability.
© 2015 Copyright by Siemens AB
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte
an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder
außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.

3
Siemens AB
Security Products 05.2015
Contents
1Product description................................................................................5
2Safety .......................................................................................................5
3Technical specifications ........................................................................6
3.1Dimensions ...............................................................................................7
4Ordering data...........................................................................................7
5Scope of delivery ....................................................................................7
6Installation...............................................................................................8
7Connections and LEDs...........................................................................9
7.1Connections..............................................................................................9
7.2Port locations ..........................................................................................10
7.3Reader wiring..........................................................................................10
7.4Wiring of monitored input........................................................................10
7.5FOR inputs..............................................................................................11
7.6Jumper settings.......................................................................................12
7.7LEDs .......................................................................................................13
8Cable specifications .............................................................................14
9Programming and firmware download ...............................................14
10Disposal.................................................................................................15
10.1Record of proper waste management.....................................................15

4
Siemens AB
Security Products 05.2015

Product description
5
Siemens AB
Security Products 05.2015
1 Product description
The ADE5300 is a Reader Interface Module (RIM) used as part of an integrated
Siemens access control and security solution. It provides an interface between an
Advanced Central Controller (AC5100) and up to eight readers/doors.
2 Safety
PLEASE NOTE We decline any liability for material damage or personal injury caused by
improper use or non-observance of these safety instructions. In such case any
guarantee expires.
PLEASE NOTE
Connection, commissioning and maintenance must only be carried out by
suitably qualified personnel.
Correct and safe operation of this device depends on proper transport, storage,
installation and connection, as well as careful operation and maintenance.
DANGER Work on electrical systems should only be performed by trained personnel
under the supervision of a certified electrician in accordance with the
appropriate regulations.

Technical specifications
6
Siemens AB
Security Products 05.2015
3 Technical specifications
Electrical
Power (input)
12 V DC, -15 to +10% or
24 V DC, -15 to +10%
Consumption max. 2 A @ 12 V, max. 1.5 A @ 24 V
(max Consumption: All Relays are driven and all open
collector outputs are supplying the max. current of 100 mA.
The reader power supplies are not included!)
Communications FLN RS-485 two wire, half-duplex
Reader Interfaces 8 x Wiegand Reader Interfaces, or
1 x Siemens RS-485 Reader Interface for
connecting up to eight Readers
Lock output 8 x Relay driven 2 A @ 30 V DC
Auxiliary output 8 x Open-Collector 100 mA @ 9.7 – 12 V DC
Inputs (internally supplied) 8 x Door contact
8 x Request-to-Exit
16 x Auxiliary
All inputs unsupervised or supervised
Supervision Requires connection of a supervision circuit.
Fire Override (FOR) input 2 x Normal or Enhanced Modes:
Normal Mode requires an Input Voltage of
12 V DC
Enhanced mode requires the connection of
22 kOhm resistor circuits. Cable must be shielded
and total cable run resistance must not exceed
100 Ohms.
Fire Override (FOR) output 2 x Relay 2 A @ 30 V DC
Local input 1 x passive device connection (unsupervised)
Local output 1 x open-collector 100 mA @ 9.7– 12 V DC
Reader Power supplies 8 x 400 mA @ 9.7 – 12 V DC
1 x 1.5 A @ 9.7 – 12 V DC
Dimensions
with baseplate (W x H x D) 250 x 287 x 50 mm (9.84 x 11.30 x 1.97")
without baseplate (W x H x D) 216 x 267 x 37 mm (8.50 x 10.51 x 1.46“)
Environmental
Operating temperature 0 – 50 °C (32 – 122 °F)
Storage temperature 0 – 60 °C (32 – 140 °F )
Humidity 10 – 90% (non-condensing)
Standards and Guidelines
European Directives
“Directive of Electromagnetic
Compatibility”
Emitted interference: EN 61000-6-3: 2001
EN 55022 +A1 +A2 Kl. B: 2003
Interference resistance: EN 50130-4 +A2: 2003
C-Tick Standard for Australia and New Zealand (equivalent
to EN 55022 of the European Directive).
UL-Directives UL 294 Access control units
Details can be found under: http://database.ul.com/cgi-
bin/XYV/template/LISEXT/1FRAME/gfilenbr.html with UL File
Number: BP9490

Ordering data
7
Siemens AB
Security Products 05.2015
3.1 Dimensions
Fig. 1 Dimensions (including base plate)
Width: 250 mm (9.84“)
Height: 287 mm (11.30“)
Depht: 50 mm (1.97")
4 Ordering data
Type Part no. Designation Weight
ADE5300 S24246-A2500-A1 Eight Reader Interface 1.3 kg
5 Scope of delivery
1 x ADE5300 mounted on base plate
1 x accessory bag (resistors for monitored inputs)
1 x installation manual English
1 x installation manual German

Installation
8
Siemens AB
Security Products 05.2015
6 Installation
Required tools & material
Medium-duty drill and associated drill-bits
4 mounting screws or standoffs (approx. 4 mm)
Flat-blade terminal screwdriver
Wire cutters
Cable strippers
Expected installation time
30 minutes
Mounting instructions
1. Remove the ADE5300 from its carton and discard the packaging material.
2. Place the ADE5300 (base plate) against the surface to which it is to be affixed
and mark the location of the mounting holes.
We recommend to mount the ADE5300 within a cabinet. Align the ADE5300
base plate with the holes located on the cabinet backplane and proceed to
step 3.
It is recommended that you affix the ADE5300 at all four of the mounting
locations provided.
Warning Do not apply power to the ADE5300 or associated components at this stage.
3. Select the appropriate drill bit according to the mounting surface / hole size
and drill the holes in the locations marked (if required).
4. Fasten the ADE5300 (base-plate) to the surface using the correct type of
screws or standoffs for the surface.
5. Connect the cabling to the ADE5300 PCB. See section 7.1: Connections.
6. Apply power to the ADE5300 and test its operation.
This step may require installation and programming of the access control host
software and download of the firmware instruction set.
Alternatively, the firmware and configuration may carried out using the FLN
Field Service Tool.

Connections and LEDs
9
Siemens AB
Security Products 05.2015
7 Connections and LEDs
7.1 Connections
It is recommended that you wear a grounding strap while carrying out this procedure.
1. Connect each Wiegand reader to the appropriate READER port of the
ADE5300, or connect the SIEMENS RS485 readers to the SRB RS485 port.
Up to 8 Siemens RS485 readers can be daisy chained (from one reader to
another) on the same connection.
Each reader must be wired correctly. For more information, see Section 7.3: Reader wiring.
The total resistance for each reader cable must not exceed 16.8 Ohms.
2. Connect the Request to Exit (REX) switch (e.g. door opener button) to the
appropriate REX input on the ADE5300.
3. Connect each door contact (door monitor) to the appropriate D/C input port
on the ADE5300. For example, connect the contact for Door 1 to “D/C1”.
4. Connect auxiliary inputs (if required) to the Input IN1 to IN16 on the PCB.
Listed end-of-line resistors must be connected to the wiring for each input device if they are to be
supervised. For more information, see Section 7.4: Wiring of monitored input.
Please note (this applies to all inputs): The total cable run resistance must not exceed 100 Ohms.
5. Connect any auxiliary output devices to the AUX OUT ports (open collector)
on the ADE5300.
6. Connect each door opener to the appropriate RELAY OUT port on the
ADE5300. Access doors can only be connected to output relays that are
controlled by readers.
7. For example, connect the lock for door 1 to the “RELAY1 OUT” connection on
the ADE5300. Ensure that the power supply used to drive the lock is
sufficiently rated.
8. Connect the wiring from the fire or emergency override system to the FOR
IN ports, if required. Ensure the correct FOR link settings are applied.
9. Connect the next device in the Fire Override sequence to the FOR OUT ports
(only if required).
10. Connect the FLN wires (from the AC5100) to the FLN RS485 port.
11. Connect the active (+ve) and neutral (-ve) wires from the Power Supply Unit
(PSU) to the DC POWER INPUT port. Ensure the polarity of the connection is
made correctly.
12. Check all jumpers. For more information, see Section 7.6: Jumper settings.
13. Check all connections thoroughly, including the polarity of each connection.
Once you have verified all connections power can be applied to the ADE5300.

Connections and LEDs
10
Siemens AB
Security Products 05.2015
7.2 Port locations
Port name Description
DC POWER INPUT DC power input (12 V DC or 24 V DC)
FLN RS485 RS-485 bus for AC5100, FLN bus
READER 1-8 Card reader: communication, power, LED’s
RELAY 1-8 OUT Door lock / strike relay driven output
D/C 1-8 Door contact
REX 1-8 Request to exit input (REX)
IN 1-16 Inputs
AUX 1-8 Open-collector 12 V DC outputs
FOR1-2 IN FOR inputs (e.g. fire alarm button)
FOR1-2 OUT FOR outputs
LOCAL IN Tamper input for local tamper detection
LOCAL OUT Alarm output (e. g. siren, strobe light)
SRB RS485 Connection for a serial card reader
SRB PWR Power output for serial card readers
7.3 Reader wiring
Wiegand reader wiring
Reader Type D0 D1 GRN RED 0 V 12 V
Wiegand D0 D1 GRN RED 0 V 12 V
RS-485 reader wiring
Reader Type S - + 12 V 0 V
RS-485 Shield - or B + or A 8V/12V 0V/GND
7.4 Wiring of monitored input
1 Connect the shielding to the housing earth.
2 Insulate the shielding at the input (e.g. door contact), do not connect it.
3 DC: door contact
4 R: terminating resistors each 22 kOhm
Fig. 2 Wiring of monitored input
FOR: Fire Override

Connections and LEDs
11
Siemens AB
Security Products 05.2015
7.5 FOR inputs
ADE5300 External device Port Remark
FORinput
(normal mode) Fire alarm system
(+ UB)
Fire alarm system output:
Fire alarm system OK
+12 V
In case of fire alarm or
malfunction
0 V
FORinput
(normal mode) Fire alarm system
(relay contact)
Fire alarm system output:
Fire alarm system OK
contact between NO and COM
closed
In case of fire alarm or
malfunction
contact between NO and COM
open
FORinput
(enhanced
mode)
Fire alarm system
(relay contact)
Fire alarm system output:
Fire alarm system OK
contact between NO and COM
closed
In case of fire alarm or
malfunction
contact between NO and COM
open
The following diagram provides an example for wiring a door lock in a fail-safe
mode for fire override operation.
FOR: Fire Override

Connections and LEDs
12
Siemens AB
Security Products 05.2015
7.6 Jumper settings
Jumper Description Value
LK1 + LK2 BIAS
These links enable the RS-485 bus biasing resistors. The
resistors create a voltage divider to force the voltage to be
less than the threshold of the receiver. This prevents invalid
data bits that are picked up from the noise on the cable from
being transmitted.
Jumper placed across LK1 and LK2:
RS485-FLN biasing resistors enabled.
LK9 – LK16 FOR OUTPUT CONTROL
These links control the Fire Over-ride activation for each
individual relay output 1-8.
Depending on where you place the link, the relay output
behaviour will be modified by FOR 1 input, FOR 2 input, or
FOR will be disabled for that relay. LK9
FOR 1
FOR 2
DIS
LK10LK11
Relay output RELAY1 OUT (LK9) is set to FOR
disabled,
Relay output RELAY2 OUT (LK10) is set to FOR 1,
Relay output RELAY3 OUT (LK11) is set to FOR 2.
LK17 and LK18
+ LK21 and LK22 FOR MODE
Configuration of the Fire Override mode:
– Enhanced FOR mode (monitored)
– Normal FOR mode (floating).
NORMAL
LK21 LK22
NORMAL
LK17 LK18
FOR 2 FOR 1
Jumpers placed over both links (e.g. FOR1):
Input set to Normal FOR mode.
Both jumpers removed (e.g. FOR2):
Input set to Enhanced FOR mode.
LK19 and LK20 +
LK23 and LK24
FOR AKTIVATION
– FOR enabled
Activation of the FOR input will cause the appropriate
output relays to pick up or drop out depending on where
the links LK9 – LK16 are placed.
– FOR disabled
The input will have no effect on the relays.
FOR disabled FOR enabled
LK25 EOL TERMINATION (Serial Reader Interface)
This link allows the Serial Card Interface communications channel to be terminated in noisy comms lines.
Note: It is only to be fitted on the first unit or the last unit on the bus.
LK26 EOL TERMINATION (FLN System Bus)
This link allows the RS485 bus communication channel to be terminated in lengthy comms lines – more than
100 m at 115 kb/s.
Note: Only units that are located at the ends of bus lines should have Link 26 set to on.
LK27 RESET (Restart)
Reset the ADE5300 retaining the unit’s firmware:
– Interrupt the power supply to the unit for 1 sec or
– Close link 27, wait for the activity LED to switch off, then remove LK2.
LK28 GP1 RESET MODE
Reset the firmware:
– Close LK28
– Close link 27, wait for the activity LED to switch off, then remove LK2.
– Remove LK28 before loading the new firmware
ENABLE
LK19 LK20
FOR 1
ENABLE
LK23 LK24
FOR 2
LK2LK1

Connections and LEDs
13
Siemens AB
Security Products 05.2015
LK29 No Link
– FOR inactive: Corresponding relays not energized
– FOR active: Corresponding relays that are energized (door released by time schedule for example) will be de-
energized.
Link Set
– FOR inactive: Corresponding relays energized
– FOR active: Corresponding relays that are de-energized (door released by time schedule for example) will be
energized.
7.7 LEDs
LED Description
ACT ACTIVITY LED
1. LED blinking quickly: Firmware needs to be downloaded
2. LED blinking slowly (approx. once per sec): Firmware has been downloaded
FLN COM The LED flashes when the ADE5300 is sending data to the AC5100.
SRB COM The LED flashes when the ADE5300 is receiving data from an RS485 card
reader.
RLY (1-8) The Output relays status is displayed as activated with green LEDs.
IN1 – IN32
REX1 – REX8
DC1 – DC8
FOR1 IN - FOR2 IN
Status of inputs
LED red: Alarm (Fire Override at FOR input)
LED green: Normal
LED orange: Tampering
LED off (only FOR1/2 IN): FOR disabled
ERROR LED active: corrupt or non fully programmable EPROM
PWR LED active: power is applied to the PCB

Cable specifications
14
Siemens AB
Security Products 05.2015
8 Cable specifications
The table provides a guideline for selecting an appropriate cable type only.
Other cable types are also compatible with the system and can be used to achieve the same results.
Communi-
cation Type Recommended Cable Specifications
Cores Pairs AWG Cores J-Y(St)Y
Diameter
(mm)
Wire Type Insulation Shield Jacket
RS-485 4 2 28 7 x 36 0.6 Tinned
Copper Foam
Polyethylene Aluminium foil - Polyester
tape / braided shield PVC
6 3
8 4
RS-232 4 2 24 7 x 32 0.6 Tinned
Copper Foam
Polyethylene Aluminium foil - Polyester
tape / no braid PVC
6 3
8 4
RS-422 4 2 24 7 x 32 0.6 Tinned
Copper Foam
Polyethylene Aluminium foil - Polyester
tape / no braid PVC
6 3
8 4
RJ-45 8 4 24
Solid 0.6 Bare
Copper Polyethylene Unshielded PVC
8 4 24
7 x 32 0.6 Tinned
Copper
RJ-12 8 4 24
Solid 0.6 Bare
Copper Polyethylene Aluminium foil - Polyester
tape / no braid PVC
8 4 24
7 x 32 0.6 Tinned
Copper
Power (12/24
V DC) 2 1 18
19 x 30 1.0 Tinned
Copper Foam
Polyethylene Unshielded PVC
9 Programming and firmware download
The ADE5300 is programmed using SiPass software, via the AC5100, or using the
„FLN Configurator“ application. Please refer to the appropriate User’s Manual for
more Information.

Disposal
15
Siemens AB
Security Products 05.2015
10 Disposal
All electrical and electronic products should be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the
government or the local authorities.
This crossed-out wheeled bin symbol on the product means the product is
covered by the European Directive 2002/96/EC.
The correct disposal and separate collection of your old appliance will help
prevent potential negative consequences for the environment and human health.
It is a precondition for reuse and recycling of used electrical and electronic
equipment.
For more detailed information about disposal of your old appliance, please contact
your city office, waste disposal service or the shop where you purchased the
product.
10.1 Record of proper waste management
A record of proper waste management is not required.

Issued by
Siemens AB
Security Products
International Headquarters
Englundavägen 7
SE-171 24 Solna
Tel. +46 8 629 0300
www.siemens.com/securityproducts
© 2015 Copyright by Siemens AB
Data and design subject to change without notice.
Supply subject to availability.
Document No. A24205-A335-B275
Edition 06.2015
Table of contents
Other Siemens IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Samsung