Contactor for capacitor switching:
Type: 3TS11.. to 3TS15.. and
3TS21.., 3TS22.., 3TS25..
IS/IEC:60947-4-1
A. Technical Data
i) Main circuit:
The capacitors are precharged during pick-up via early-make
contacts and integrated pre-charge resistors before the main
contacts close.
This combination may be used for switching of Individual
capacitor for power factor correction of single loads or for
switching capacitor banks in parallel in centralized group
power factor correction system.
• InsulationVoltageUi=690VAC,
Temperature:Storage-25to+55ºC
 Service(withoutderating)-25to+40ºC
Usethedeviceswiththedeclaredcapacitorbankratingsonly.
Contactor Type Load of contactor when switching
3ph-AC capacitor kVAr at 415/440V, 50Hz
3TS21..-0A..5-8K 5
3TS11..-0A..5-8K 7
3TS22..-0A..5-8K 10
3TS12..-0A..5-8K 12.5
3TS13..-0A..5-8K 16
3TS14..-0A..5-8K 20
3TS15..-0A..5-8K 25
3TS25..-0A..5-8K 30
• Switching frequency in Make/Break operations:
180Operatingcycles/hourforallratings
• Maximum back-up fuse rating:ForType-1Coordination
Type-3NA7asperIEC60269
:1.6…1.8Ie
ii) Aux Circuit:
Inbuilt: Auxiliary Contacts
1NO+1NCincaseof3TS1211To3TS1511and3TS2211,
3TS2511
Nobuilt-inauxiliarycontactsfor3TS1200To3TS1500and
3TS2200,3TS2500
1NOincaseof3TS11...and3TS21...
Additional Aux:
Facilitytoadd-on1NOor1NCauxiliarycontactblock
type3TX40..isavailablefor3TS11..,3TS1200,3TS1300,
3TS1400,3TS1500,3TS21..,3TS2200,3TS2500
3TX 40.. Block tment (For 3TS11.., 3TS1200, 3TS1300,
3TS1400, 3TS1500, 3TS21.., 3TS2200, 3TS2500)
Aux Contact Rating:
3TX40
IeAC-15=3.6Aat415V
IeDC-13=0.48Aat220V
Note: Do not remove precharging resistors. If contactor is
switchedonloadwithoutresistor,itmaycausedamageto
the contactor.
iii) Control circuit:
• Controlvoltageismarkedonthecolouredidentication
tag on the coil.
Note:
• Thevoltageistobemaintainedwithinallowablelimits.
• Operationonundervoltageconditionstothecoilmay
causedamagetothecoil/contactor.
• Maximumback-upfuseratingforcontrolcircuit=16A
=6Aifrelaycontactisinthecontrolcircuit.
iv) Internal connection diagram
3TS11..-0A..5-8K
3TS21..-0A..5-8K
3TS13..-0A..5-8K
3TS22..-0A..5-8K
 InbuiltNOincaseof5kVAr&7kVAr
Fig. 1
ConnectionDetailsfor
3TS11…to3TS15...
and3TS21...,3TS22...,
3TS25... is shown in
gure1
Operating Instructions
Avoidoperationduringundervoltage
conditions. Switch only onto discharged
capacitors.Manualoperationnotpermitted
for function testing.
Warning:
Commissioningandmaintenanceby
qualiedpersonnelonly.Followthe
operating instructions.
Do not remove precharging resistors. If
contactorisswitchedonloadwithoutresistor,
it may cause damage to the contactor.
Hazardous Voltage can cause Electric
Shock and burns.
Disconnect Power before proceeding with
any work on this equipment.
B. Installation
1. Permitted mounting positions are indicated in Fig.2
2. Theunitissuitableforscrewmountingonatvertical
surfacewithtwoM4screws.Alwaysuseplainandspring
washers.
3. Alternativelysnapfor3TS11..to3TS15..and3TS21..,
3TS22..,3TS25..ontoa35mmTophatRailTH35asper
DIN:EN60715.
Note:Installtheunitinhousingifitisexposedtodust,dirt,
contamination or aggressive atmosphere.
C. Maintenance
• Removedustbysuction.
• Replacementofcoilavailableasspare.
• Sparecontactkitsavailablefrom3TS12to3TS15and
3TS22,3TS25.
• ContactSiemensSalesofcefordetails.
• Handletheresistorwirescarefully.
D. Note:
NormallythepowerfactorcontrollerinAPFCpanels,hasthe
provision for adjustment under voltage cut out with respect
to voltage and time. Please ensure that the controllers are
present as per values given in the table on right side.
Coil Voltage
available in
MLFB’s
Coil
Voltage
Controller settings
Under Voltage setting Actuating time
3TS11 to 3TS15
and3TS21,
3TS22,3TS25
110V ≥94V <0.1sec
230V ≥196V <0.1sec
415V ≥353V <0.1sec
3TS11 to 3TS15 220-230V ≥187V <0.1sec
400-415V ≥340V <0.1sec
Incase,Powerfactorcontrollerdoesnothavetheprovision
ofabovesettings,itisrecommendedtoprovideaseparate
undervoltagemonitorhavingsettingsaspertable,toensure
satisfactory performance of the contactors. For further details
onsuchanundervoltagemonitor,pleasecontactnearest
Siemensofce.
Fig. 2 Mounting Positions for 3TS11... to 3TS15... and 3TS21...,
3TS22..., 3TS25...
Permissible Conductor Size: Main Terminals
Termination Data -
Contactor Cable 3TS11..-0A..5-8K 3TS12..-0A..5-8K 3TS13..-0A..5-8K 3TS14..-0A..5-8K 3TS15..-0A..5-8K
3TS21..-0A..5-8K 3TS22..-0A..5-8K 3TS25..-0A..5-8K
Solid mm21 x (1 to 2.5) 1x(2.5to6) 1to16 1to16 1to16
Flexible without end sleeve mm2– – 1.5to16 1.5to16 1.5to16
Flexible with end sleeve mm21x(0.75to2.5) 1 x (1.5 to 4) 1.5to16 1.5to16 1.5to16
Screw Size M3.5 M4
Tightening Torque N-m 0.8to1.4 1.0to1.5 2.5 to 3
Insulation cutting length
for wires mm 10
Siemens Limited
OrderNo.A5E03830809000A-AF
Productdevelopmentisacontinuousprocess.Consequently
thedataindicatedinthisLeaetissubjecttochangewithout
priornotice.Forlatestissuecontactoursalesofces.
SACHINENTERPRISE
Disposal
Siemensproductareenvironmentfriendly,whichpredominantly
consist of recyclable materials.
For disposals we recommend disassembling and separation into
following materials:
METALS:SegregateintoFerrous&NonFerroustypesforrecycling
through authorised dealer.
PLASTICS:Segregateaspermaterialtypeforrecyclingthrough
authorised dealer. Because of the long lifetime of Siemens
products the disposal guidelines may be replaced by other national
regulations when taking the product out of service.
The local customer care service is available at any time to answer
disposal-related questions.
CustomerCareTollfreeno.18002090987 Email:[email protected]
S17936
E. Overall Dimensions
Dimensional drawing: 7/12.5, 16, 20, 25, 5, 10, 30kVAr (3TS11/12/13/14/15/21/22/25..-0A..5-8K)
Type A B C D FG H J K L Ø E M Term
Screw
3TS11/3TS21 125 74 60 10 115 78 45 60 35 – 4.8 48 M3.5
3TS1200/3TS2200 136 85 70 14.5 115 85 45 75 35 – 4.8 51 M4
3TS1300..1500/3TS2500 148 85 63 18 120 103 55 75 45 – 5 62.5 M4
3TS1211/3TS2211 136 85 70 14.5 115 85 45 75 35 58 4.8 51 M4
3TS1311..1511/3TS2511 148 85 63 18 120 103 55 75 45 68 562.5 M4

This manual suits for next models

4

Other Siemens Switch manuals

Siemens 3VF9621 Series User manual

Siemens

Siemens 3VF9621 Series User manual

Siemens RUGGEDCOM RS900GF User manual

Siemens

Siemens RUGGEDCOM RS900GF User manual

Siemens Powers SW 141 Series Owner's manual

Siemens

Siemens Powers SW 141 Series Owner's manual

Siemens SIMATIC RUGGEDCOM RSG2100P User manual

Siemens

Siemens SIMATIC RUGGEDCOM RSG2100P User manual

Siemens SCALANCE XR-100WG Series User manual

Siemens

Siemens SCALANCE XR-100WG Series User manual

Siemens Sivacon S8 User manual

Siemens

Siemens Sivacon S8 User manual

Siemens NCM S7 User manual

Siemens

Siemens NCM S7 User manual

Siemens SCALANCE XC-200 Instruction sheet

Siemens

Siemens SCALANCE XC-200 Instruction sheet

Siemens RUGGEDCOM RX1500 User manual

Siemens

Siemens RUGGEDCOM RX1500 User manual

Siemens SIMATIC NET RUGGEDCOM RX1511 User manual

Siemens

Siemens SIMATIC NET RUGGEDCOM RX1511 User manual

Siemens SIMATIC NET SCALANCE X-100 User manual

Siemens

Siemens SIMATIC NET SCALANCE X-100 User manual

Siemens 5WG1 523-1AB03 User manual

Siemens

Siemens 5WG1 523-1AB03 User manual

Siemens S 563 User manual

Siemens

Siemens S 563 User manual

Siemens BT300 LonWorks User manual

Siemens

Siemens BT300 LonWorks User manual

Siemens RUGGEDCOM RSG2100PF User manual

Siemens

Siemens RUGGEDCOM RSG2100PF User manual

Siemens 3VM11 1AA Series User manual

Siemens

Siemens 3VM11 1AA Series User manual

Siemens SIMATIC NET RUGGEDCOM RS940GF User manual

Siemens

Siemens SIMATIC NET RUGGEDCOM RS940GF User manual

Siemens RUGGEDCOM RS900GF User manual

Siemens

Siemens RUGGEDCOM RS900GF User manual

Siemens RUGGEDCOM RS950G User manual

Siemens

Siemens RUGGEDCOM RS950G User manual

Siemens SIRIUS User manual

Siemens

Siemens SIRIUS User manual

Siemens 5SV4 Series User manual

Siemens

Siemens 5SV4 Series User manual

Siemens Pointek CLS200 Instruction manual

Siemens

Siemens Pointek CLS200 Instruction manual

Siemens CNFS Series User manual

Siemens

Siemens CNFS Series User manual

Siemens RUGGEDCOM RMC41 User manual

Siemens

Siemens RUGGEDCOM RMC41 User manual

Popular Switch manuals by other brands

Linkskey LKS-SR16 user manual

Linkskey

Linkskey LKS-SR16 user manual

G&D miniMUX2 Installation and operation

G&D

G&D miniMUX2 Installation and operation

IS5 COMMUNICATIONS iSG18GFP user manual

IS5 COMMUNICATIONS

IS5 COMMUNICATIONS iSG18GFP user manual

Ruijie HS2310-16GH2GT1XS Hardware  installation and reference guide

Ruijie

Ruijie HS2310-16GH2GT1XS Hardware installation and reference guide

HP 10500 series Configuration guide

HP

HP 10500 series Configuration guide

Edge-Core ES3526VA-PoE installation guide

Edge-Core

Edge-Core ES3526VA-PoE installation guide

Belkin F1DN102KVM-UN-3 Quick installation guide

Belkin

Belkin F1DN102KVM-UN-3 Quick installation guide

FISCHER DS 11 operating manual

FISCHER

FISCHER DS 11 operating manual

NETGEAR AV Series user manual

NETGEAR

NETGEAR AV Series user manual

Topworx DXR-GO Installation, operation & maintenance manual

Topworx

Topworx DXR-GO Installation, operation & maintenance manual

serverLink SL-271-D Quick installation guide

serverLink

serverLink SL-271-D Quick installation guide

Digital Equipment VNswitch 900EF Installation and configuration

Digital Equipment

Digital Equipment VNswitch 900EF Installation and configuration

Grizzly H8238 instructions

Grizzly

Grizzly H8238 instructions

MicroNet SP508C user guide

MicroNet

MicroNet SP508C user guide

Sturmey-Archer AW Series technical information

Sturmey-Archer

Sturmey-Archer AW Series technical information

Panasonic Swtich-M48eG Series installation guide

Panasonic

Panasonic Swtich-M48eG Series installation guide

Linksys SRW2024 Specifications

Linksys

Linksys SRW2024 Specifications

IFM AC901S Original operating instructions

IFM

IFM AC901S Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.