Simplicity 10 LE Series User manual

A (mm) B (mm)
3150
10’4” x 6’3” 1910
10’4” x 8’3” 2530
10’4” x 10’4” 3150
10’4” x 12’4” 3770
R A N G E

KEY
SYMBOL
KEY DESCRIPTION
LOOK
THINK / CHOOSE?
THIS SECTION
RELATES TO ANOTHER
(e.g. 1 to 5)
CORRECT
DO NOT FIX DOWN!
TWIST TO LOCK
TIGHTEN
DO NOT WET!
Thank you for purchasing your new Simplicity greenhouse. We recommend you familiarise yourself with the instructions and read all safety
information before you commence assembly. This instruction manual is also available online at www.greenhousepeople.co.uk in our technical
help section should you need to reprint it. Should you require any additional advice you can always call us on 01782 388811.
These instructions are divided into sections; B-base, partlists,1-sides, 2-front gable, 3-rear, 4-joining the four sides together, 5-roof, 6-vent, 7-door,
8-glazing(8a horticultural glass, 8b toughened glass, 8c polycarbonate glazing when available), 9-vent attachment, 10-door attachment, 11 anchoring
down, back cover-packing list. If you need to contact us for assistance please refer to the relevant section/s.
Safety Warning
Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when
assembling and glazing the building.
Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately.
Do not assemble the greenhouse in high winds.
For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people.
Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse.
Site Preparation
When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible.
A concrete or slabbed base will provide the most solid foundation for your greenhouse.
IMPORTANT: Do not fix your building down until the building is fully assembled, including glazing.
Avoid placing your greenhouse under trees or in other vulnerable locations.
To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence.
Additional Considerations
Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more
days. We recommend that you avoid leaving the building partially glazed. If you ever have to leave your greenhouse half assembled and not
anchored down, weigh it down with slabs or bags of sand to stop the wind moving it.
You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal.
If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered
and can be identified by a stamp or removable label. Alternatively, the components can be identified by lengths detailed in the packing list (see
diagram below).
Anchoring down your greenhouse should be the final stage of construction (including glazing).
Once installed your greenhouse requires little maintenance, but to maintain the smooth running of your door(s) WD40 or similar can be applied
to the door wheels and lower door guides.
Guarantee
Your new Simplicity greenhouse is guaranteed for 10 years against faulty manufacture of the framework. This does not include glazing, moving
parts, accidental damage or wind damage.
610mm
121

OPTION 1: base on grass
OPTION 2: base on slabs
OPTION 3: base on concrete
OPTION 4: no base on brick
A (mm) B (mm)
3150
10’4” x 6’3” 1910
10’4” x 8’3” 2530
10’4” x 10’4” 3150
10’4” x 12’4” 3770

Page
Ref
Part
No.
Section Size
(mm)
10
6
10
8
10
10
10
12
10
LE
Page
Ref
Part
No.
Section Size
(mm)
10
6
10
8
10
10
10
12
136
924
2
185
3076
1
197
2190
2
51
1480
4
183
3096
1
2
4
10
2488
1
300
n/a
12
14
16
18
1 3720 2
5 3100 2
17 2480 2
25 1860 2
3 3720 2
8 3100 2
14 2480 2
27 1860 2
49
1314
4
32
1210
4
6
8
10
2 3720 1
6 3100 1
12 2480 1
26 1860 1
188
1866
4
6
8
10
187
1920
4
93
636
1
2
3
4
601
608
4
6
8
10
602
900
2
3
4
5
184
3096
1
36
1857
2
38
2
70
1538
2
71
2
186
2269
1
191
480
1
189
1855
2
190
2
30
1210
2
31
2

Page
Ref
Part
No.
Section Size
(mm)
10
6
10
8
10
10
10
12
10
LE
Page
Ref
Part
No.
Section Size
(mm)
10
6
10
8
10
10
10
12
10mm
M4
M6
121
612
1
2
3
4
123
612
1
2
3
4
124
610
2
4
6
8
1
2
3
4
2
4
6
8
6
12
18
24
2
4
6
8
130
619
41 a
1763
1
41
1763
3
95
614
2
137
883
4
4
4
4
4000
1
8
167
+
300
380
2
2
2
234
266
298
330
108
126
144
162
6
roll
7
roll
8
roll
9
roll
161
173
185
197
171
185
199
213
8
M6 CROP
M6
M6

Part No mm Quantity
8 3100 2
32 1210 8
5 3100 2
49 1314 4
M6 28
M6 28
Part No mm Quantity
14 2480 2
32 1210 6
17 2480 2
49 1314 4
M6 22
M6 22
Part No mm Quantity
27 1860 2
32 1210 4
25 1860 2
49 1314 4
M6 16
M6 16
Part No mm Quantity
3 3720 2
32 1210 10
1 3720 2
49 1314 4
M6 34
M6 34
6’
8’
10’
12’
27
25
14
17
8
5
3
1
X 2
X 2
X 2
X 2
+
+
+
+
+
+
+ +
+ +
+ +
+ +

49
32
32

Part No mm Quantity
10 2488 1
30 1210 1
31 1210 1
36 1857 1
38 1857 1
51 1480 2
70 1538 1
Part No mm Quantity
71 1538 1
136 924 2
184 3096 1
189 1855 1
190 1855 1
191 480 1
38 38
M6
2
1
184
36 38
51
30 31
136
189 190
136
51
70 71
136
51
191
This bar is currently
riveted to the door
track assembly (10).

184
51
36 /
38 184
30 /
31
189 /
190
51
136
30 /
31
189 190
191
36 /
38
189 /
190
10
10
161
This bar is currently
riveted to the door
track assembly (10).

Part No mm Quantity
30 1210 1
31 1210 1
36 1857 1
38 1857 1
51 1480 2
70 1538 1
71 1538 1
183 3096 1
185 3076 1
Part No mm Quantity
186 2269 1
189 1855 1
190 1855 1
197 2190 2
45 45
M6
2
1
183
36 38
51
30 31
189 190
185
51
70 71
186
197
197
51
185

36 /
38
189 /
190
183
30 /
31
183
51
36 /
38
185
189 190
186
189 /
190
30 /
31
51
185
197
189 /
190

This bar is currently riveted to the
door track assembly (10). Please
ignore at this stage. Part 10 fitted
in section 10.

18mm
7mm
If you have a metal base and you live in a windy
location then you should drill and fix the frame to
the base using 10mm nuts and bolts. Drill centrally
between two vertical glazing bars for neatness (it is
not essential to drill every section). Make sure the
bolt head does NOT interfere with the line of the
glass. Cills should be drilled 18mm from the inside
vertical face to avoid the front glass face. Do NOT
anchor the structure to the ground until the end!
Packed with base!
M6 CROP

8’ Part No mm Quantity
12 2480 1
93 636 2
187 1920 4
188 1866 6
601 608 6
602 900 3
32
6’ Part No mm Quantity
26 1860 1
93 636 1
187 1920 4
188 1866 4
601 608 4
602 900 2
22
1 2
1
2
3
4
4 188
3
187
187
188
188
187
49

12’ Part No mm Quantity
2 3720 1
93 636 4
187 1920 4
188 1866 10
601 608 10
602 900 5
52
10’ Part No mm Quantity
6 3100 1
93 636 3
187 1920 4
188 1866 8
601 608 8
602 900 4
42
X 2
M4 X 4
602
601
93

124
121
121
124
610 x 610
M6 10mm X 2
X 2
X 4
M4 X 2
M4 X 2
X 4 or
OPTIONAL
CAPPING
X 1
1220mm
Part No mm Quantity
121 612 1
123 612 1
124 610 2

123
610 x 610

Part No mm Quantity
41 1763 3
95 614 2
41a 1763 1
130 619 8
137 883 4
130
95
41
41a
41
41
130
95
130
137
137
130 130
130
FLUFF
FLUFF
M6 32 32M6
X 4
X 2
7.6 m
FLUFF
4 m
X 4
X 4

95
130
13041
41 41a
41
Please note that you may need
to change the orientation of the
diagonal flat bar braces in your
door/s to make fitting your door
stop easier. i.e. the diagonals
can be fitted in either orientation.
FLUFF

Table of contents
Other Simplicity Greenhouse Kit manuals
Popular Greenhouse Kit manuals by other brands

Halls Greenhouses
Halls Greenhouses Universal installation manual

PTF
PTF PEPPER PTF 4 Assembly manual

FRAME IT ALL
FRAME IT ALL Walk-through Center Cross 12x12 manual

ACF Greenhouses
ACF Greenhouses Grow More GM8 Assembly instructions

C.A.P.
C.A.P. XGC-1e Specification sheet

Juliana
Juliana 05022016-MG Assembly instruction

Palram
Palram CANOPIA AMERICANA 12x12/3.7x3.7 How to assemble

Alton
Alton AMATEUR CEDAR GREENHOUSE 6' Wide Assembly instructions

Vitavia
Vitavia VM0005-V 6200 Assembly instructions

oGrow
oGrow OG03-PE5565E product manual

Janssens
Janssens GIGANT Mounting instructions

Penguin
Penguin W1608-GP-12 instruction manual