manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Simrad
  6. •
  7. Measuring Instrument
  8. •
  9. Simrad PI44 C Instruction Manual

Simrad PI44 C Instruction Manual

Other manuals for PI44 C

2

This manual suits for next models

3

Other Simrad Measuring Instrument manuals

Simrad PI50 -  REV A User manual

Simrad

Simrad PI50 - REV A User manual

Simrad PI32 User manual

Simrad

Simrad PI32 User manual

Simrad PI44 C User manual

Simrad

Simrad PI44 C User manual

Simrad PI54 A User manual

Simrad

Simrad PI54 A User manual

Simrad PI50 -  REV A User manual

Simrad

Simrad PI50 - REV A User manual

Simrad FX80 User manual

Simrad

Simrad FX80 User manual

Simrad PI PURSE SEINE HYDROPHONE - INSTALLATION REV... User manual

Simrad

Simrad PI PURSE SEINE HYDROPHONE - INSTALLATION REV... User manual

Simrad PI TRAWL HYDROPHONE - INSTALLATION REV B User manual

Simrad

Simrad PI TRAWL HYDROPHONE - INSTALLATION REV B User manual

Simrad PI30 User manual

Simrad

Simrad PI30 User manual

Simrad PI44 C User manual

Simrad

Simrad PI44 C User manual

Simrad PI54 A User manual

Simrad

Simrad PI54 A User manual

Simrad SAL R1a Easy Tank User manual

Simrad

Simrad SAL R1a Easy Tank User manual

Simrad PI50 -  REV A User manual

Simrad

Simrad PI50 - REV A User manual

Simrad ITI TRAWL SYSTEM User manual

Simrad

Simrad ITI TRAWL SYSTEM User manual

Simrad PI50 -  REV A User manual

Simrad

Simrad PI50 - REV A User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Software release note
Simrad PI44/54 Catch monitoring SW 2.00/2.01
TECHNOLOGY FOR SUSTAINABLE FISHERIES
www.simrad.com
Introduction
This document describes the
software and other changes introduced
with the following software:
• MMI SW version 2.00
• DSP SW version 2.01
The Man-Machine Interface
(MMI) software is the PI44/54
program that controls the menu
system and presentations. The DSP
software controls the operation of the
digital signal processor.
Documentation
The operator manuals for PI44 and
PI54 are not changed.
How to install the new SW
Registered Simrad dealers can
download the new software versions
from the Simrad Dealer Club. All
relevant procedures are also available
from the same site.
End users must contact their
Simrad dealer for assistance.
MMI Software
The new MMI software version
isdistributedasanISOle.Inorder
toinstallthesoftware,youmustrst
burnthisISOletoaCDusingthe
“burnCDfromimage”feature(or
similar).
Turn the page...
In order to upload the software
you will need a personal computer, a
special upload cable (can be obtained
from Simrad) and the installation
instructions.
DSP Software
The new version of the DSP
(Digital Signal Processing) must
be installed after the MMI software
upgrade. In order to have a fully
functional MMI, the DSP software
must be upgraded.
Software changes
See page 2.
165255 / Rev.D / April 2010
Kongsberg Maritime AS
Strandpromenaden 50
P. O.Box111
N-3191 Horten,Norway
Simrad
Telephone: +4733034000
Telefax: +4733042987
simrad.sales@simrad.com
www.simrad.com
Simrad PI44/54
Software changes
MMI Software 2.00
• AllparametersrelatedtoSensor
alarm and Calibration have
been moved to the Sensor
Conguration dialog.
• CatchltersettingMedium
introduced.
• Offsetvaluesfrom9.9to99.9
units implemented for Height,
Geometry, Depth and Spread
sensors.
• BuginDepthbarscorrected.
• Bottomdetectorinechosounder
improved to provide a more stable
marker when using bottom related
echograms.
• GeometryDF(differential)
implemented.
• GeometrySensitive/Course
presentations introduced
• Geometrycolourcodedmarkers
introduced to indicate port and
starboard measurements.
• Sensorcongurationapplication
improved by enhancing the
communication between the MMI
and DSP software.
• Correctederrorinmarkerlinefor
temperature.
• Minorbugxes.
DSP Software 2.01
• Modieddetectortobetter
withstand interference.
• Implementednewsensors.
• Implementedheavylteringforall
analogue and digital sensors.
• Changedtoavoidtimeoutwhen
severalsensorsareconguredin
slow update rate, or when many
catch sensors are used.
• Enlargedrangeforvalid
calibrationsoffsetfrom[-9.9,…,
9.9]to[-99.9,…,99.9]
• Dynamichandlingoflowerbound
for negative measured values.
• Correctedpossibleerrorwhere
congureddepthsensorloosesthe
depth value.
• Calibrationisperformedwith
the user settings used before
calibration started. No interference
lterforcedon,andnopredened
noise level used.
• Minorbugxes.