SImx LHT0182 User manual

working LED
light sensor
This sensor is an active motion detector, it emits high-frequency
electro-magnetic waves, 5.8GHz and receives their echo.
The sensor detects the change in echo from even the slightest
movement in the light detection zone.
A microprocessor then triggers the “switch light ON” command.
Detection is possible through doors, panes of glass or thin walls
in most applications.
More reliable at distance than using IR or optical sensors, as
there are no gaps in the detection zone.
Model: LHT0182 Microwave Sensor
INSTALLATION INSTRUCTIONS
We strongly recommend that this sensor is installed by a suitably qualified and registered electrician.
Please read the entire Installation Manual and Calibration instructions before installing this product.
All electrical work must be carried out in accordance with local and national electrical codes as applicable.
Always switch power off prior to installation.
A means of power isolation must be installed on the circuit for the purpose of safe access for any internal
cleaning, recalibration or maintenance.
This appliance is not intended for installation or calibration by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given
supervision or instruction concerning its use by a person responsible for their safety.
There are no user-serviceable parts in this product.
Any changes or modifications made or attempted to this product without the prior written approval of the
manufacturer will void any and all stated warranties. This excludes normal calibration of the Reach, Time
and Light control setting knobs as described in these installation instructions.
IMPORTANT
!
Power supply: 220-240 VAC
Power frequency: 50Hz
Installation: Indoors, surface mounting
Hf system: 5.8Ghz CW radar ISM band
Transmission power: <10mW
Max rated load: 1200W 5A resistive (incandescent)
200W2.5A(uorescentandCFL)
Eective mounting height: Up to 4.0 metres
Detection angle: 360°
Reach: 2 - 20m dia. Adjustable
Time setting: 5sec to 12min (approx)
Light control: 2~2000lux
Power consumption: approx.0.9W
IP rating: IP20
Temperature range: -10°C ~ 55°C
TECHNICAL SPECIFICATIONS
!
Malfunction Cause Remedy
The load will not work
Wrong light-control setting selected Adjust setting
Loadfaulty Change load
MainsisswitchedOFF Switch ON
The load is always ON Continuous movement in the detection zone Check zone setting
The load is ON
withoutanyidentiable
movement
The sensor not mounted for detecting
movement reliably Securely mount enclosure
Movementoccurred,butnotidentied
by the sensor (movement behind wall,
movement of a small object in immediate
lamp vicinity etc)
Check zone setting
The load will not work
despite movement
Rapid movements are being suppressed to
minimise malfunctioning or the detection
zone you have set is too small
Check zone setting
TROUBLESHOOTING
Distributed by:SimxLimited|Ph:092591660|TechnicalSupportPh:092591662
Email:[email protected]|Web:www.simx.co.nz
Simx reserves the right to alter technical specications without prior warning PUB1163 iss03 11/14
This product is guaranteed by SIMX Ltd for 36 Months from the date of purchase against faulty materials
or workmanship which affects its designed ability to operate. During this period if the product has a
defect of this nature it will be repaired or replaced free of charge by SIMX with the same item, or a
similar one of higher specification. ON CONDITION THAT:
The buyer returns it to the seller from whom it was bought, freight paid.
The product has been bought by the user. ie a receipt/sales invoice is produced as proof of purchase.
The product has not been misused or handled carelessly, installed in anyway contrary to the installation
instructions, used on a supply voltage other than that indicated in the product specifications, or installed
in any unusually exposed or harsh environmental conditions.
This guarantee excludes liability for discolouration of paint or plastic, or any user serviceable parts. It
does not confer any rights other than those expressly set out above and does not cover any claims for
consequential loss or damage.
Our Goods come with guarantees that cannot be excluded under the New Zealand Consumer Law.
You are entitled to a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced if
the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
MANUFACTURERS WARRANTY

2m
1. Always isolate mains power prior to installation.
2. Remove cover by turning anti-clockwise and remove the 2 screws as shown.
3. Use the base to mark the drill holes on the mounting surface.
4. Drill holes and insert wall plugs if required.
5. Feedpowercableandloadcablethroughbaseholesandsecurelyaxbase.
6. Connect the power wire and the load wire to the connection terminal according
totheelectricalconnectionFig1.Donotexceedthemaxratedload.
7. Replace&securebasecover,calibrate(Fig2)andreplacefrontcover.
N L' L
Reach setting (Sensitivity)
Reach is the term used to describe the diameter of the more or less
circular detection zone produced on the ground after mounting the
sensor at a height of 2.5m.
Turn the reach control fully anti-clockwise to select minimum reach
(approx. 2m dia), and fully clockwise to select maximum reach
(approx. 20m dia). Adjust according to location and site requirements.
Time setting
The light can be set to stay ON for any period of time between approx.
5sec (turn fully anticlockwise) and a maximum of 12min (turn fully
clockwise). Any movement detected before this time elapse will re-start
the timer. It is recommended to select the shortest time for adjusting
the detection zone and for performing the walk test.
NOTE:afterthelightswitchesOFF,ittakesapprox.1secbeforeitis
able to start detecting movement again. The light will only switch on in
response to movement once this period has elapsed.
Light-control setting
The chosen light response threshold can be adjusted from approx.
2-2000lux. Turn it fully anti-clockwise to select dusk- to-dawn
operation at about 2 lux.
Turn it fully clockwise to select continuous daylight operation .
The knob must be turned fully clockwise when adjusting the detection
zone and performing the walk test in daylight, then adjust setting
according to site requirement.
INSTALLATION PROCEDURES
ELECTRICAL CONNECTION (FIG 1)
ConnectNandLwithpower
ConnectNandL1to the load
!
5sec~15min
5sec~12min
2~2000LUX
2~2000LUX
1-8m dia
2-20m dia
CALIBRATION SETTINGS (FIG 2)
Fig 1
DETECTION ZONES FOR CEILING MOUNTING
(AT 2.5 METRES)
1. Minimum reach 2m dia.
2. Maximum reach 20m dia.
fig.1
fig.2
fig.3
fig.1
fig.2
fig.3
Step Process
Important: People or objects
moving towards the sensor are
more likely to be detected.
!
MIN MAX
Important:
1. This microwave sensor cannot penetrate through metal objects.
2. Forreliableoperation,avoidinstallinginareaswithnotableair
turbulenceorceilingmovemente.g.belowmezzanineoors.
!
Fig 2
20m
NOTE: The high-frequency output
of this sensor is <10Mw - that is
just one 50th of the transmission
power of a mobile phone or the
output of a microwave oven.
!
Other SImx Accessories manuals
Popular Accessories manuals by other brands

BabyGo
BabyGo Buggy Board Assembly instructions

Aginova
Aginova Sentinel Next Series reference guide

August
August LP105R user manual

PCB Piezotronics
PCB Piezotronics 353B02 Installation and operating manual

Fishman
Fishman PRO-EQ user guide

Motorline professional
Motorline professional MF103 Operating & programming manual