sisel ENDA ET1413R User manual

SN: XXXXXXXXX
ET1413R-NTC-230VAC
DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4.5VA
CIRCULATION
250V AC 8A
RESISTIVE LOAD
COAL
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
FAN
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 78910 11 12
12V AC/DC 10%
50/60Hz 4.5VA
±
SN: XXXXXXXXX
ET1413R-NTC-12
DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
CIRCULATION
250V AC 8A
RESISTIVE LOAD
COAL
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
FAN
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
24V AC/DC 10%
50/60Hz 4.5VA
±
SN: XXXXXXXXX
ET1413R-NTC-24
DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
CIRCULATION
250V AC 8A
RESISTIVE LOAD
COAL
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
FAN
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
1/2
SET
°C
SET
ET1413R
ENDA
COAL CIR
FAN
COAL
35mm
77mm
SET
°C
SET
ET1413R
ENDA
COAL CIR
FAN
COAL
SN: XXXXXXXXX
ET1413R-NTC-230VAC
DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4.5VA
CIRCULATION
250V AC 8A
RESISTIVE LOAD
COAL
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
FAN
250V AC 8A
RESISTIVE LOAD
1 2 3 4 5 6 7 8 9 10 11 12
1 - Supply Voltage
230........230V AC
24 ........24V AC/DC
12 ........12V AC/DC
ET1413R-NTC -
1
Order Code :
ET1413R-EN-01-170404
ENDA
TM
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
Please read this document carefully before using this product. The guarantee will be invalidated if the
device is damaged by not following instructions detailed in the manual. The company shall not be
responsible for any damage or losses however caused, which may be experienced as a result of the
installation or use of this product.
ENDA ET1413R RADIATOR CONTROLLER
Thank you for choosing ENDA ET1413R Radiator Controller.
35 x 77mm sized.
On-Off control.
CIRCULATION, COAL and FAN control outputs.
Coal output can be set by depending on temperature
duration or manually.
Upper and Lower alarm limits can be configured to
dependent on set value.
CE marked according to the European Norms.
Upper and Lower setpoint value limits can be adjusted.
Connection Diagram
ENDA ET1413R is intended for installation in control panels. Make sure that the device is used only
for intended purpose. The electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations. During an installation, all of the cables that
are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is
not exceeded. The cables should not be close to the power cables or components.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout by
DOUBLE INSULATION
SUPPLY:
NOTE:
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
7
8
Technical Specifications
CONTROL
ENVIRONMENTAL CONDITIONS
Ambient / Storage Temperature
Relative Humidity
Protection class
Height
Do not use the device in locations subject to corrosive and flammable gasses.
ELECTRICAL CHARACTERISTICS
Supply Voltage
Power Consumption
Connection
Scale
Sensitivity / Accuracy
Time Accuracy
Display
EMC
Safety Requirements
OUTPUTS
Coal Output Relay
Circulation Output Relay
Fan Output Relay
Control Type
Control Algorithm
Hysteresis
HOUSING
Housing Type
Dimensions
Weight
Enclosure Material
Max. 2000m
0 ... +50°C/-25 ... 70°C (without icing)
According to EN60529; Front panel : IP65
Rear Panel : IP20
Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Max. 4.5VA
2.5mm² screw-terminal connections
For Time Unit (±% 1-15sec), For Minute Unit (±% 1-1sec)
4 digits, 12.5mm, 7 segment LED
EN 61326-1: 2013 (Provides performance criterion B for EMC experiments.
The device is intended for use in controlled electromagnetic environments.)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
0 ... +150.0°C
0.1°C / ±1°C
230V AC +%10 -%20, 50/60Hz ; 12V AC/DC ± %10 or 24V AC/DC ±%10
NO 250V AC, 8A ( ), 1/2hp, 0.37kW 240V AC CosF = 0.4 ( )
+NC for resistive load for inductive load
NO 250V AC, 8A (for resistive load), 1/2hp, 0.37kW 240V AC CosF = 0.4 (for inductive load)
NO 250V AC, 8A (for resistive load), 1/2hp, 0.37kW 240V AC CosF = 0.4 (for inductive load)
Single set-point control
On-Off control
Adjustable between 1 ... 20.0 °C.
Suitable for flush -panel mounting
W77xH35xD71mm
Approx. 190g (After packing)
Self extinguishing plastics.
While cleaning the device, solvents (thinner, gasoline, acid etc.) or corrosive materials must not be used.
Life Expectancy for Relay 30.000.000 Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC.
DIMENSIONS
Note:
1) Panel thickness should
be maximum 7mm.
2) If there is no 60mm free
space at the back side of
the device, it would be
difficult to remove it from
the panel.
Flush mounting
clamp
For removing mounting clamps:
- Push the flush-mounting
clamp in direction 1 as shown
in the figure below.Then,pull
out the clamp in direction 2 .
71,5mm
28,5mm
Panel Cut-out
71mm 5mm
Flush mounting
clamp Panel Rubber
packing
2
Depth
1
SET
°C
SET
ET1413R
ENDA
COAL CIR
FAN
COAL
Themperature set
value for
COAL
Coal
Stoking Coal
Duration
C.dur
Fan
Lower limit for
circulation set
value
C.Lol
C.int
A.Lol
C.upl
A.upl
Parameter
security code
60.0
8
60.5
20.0
5.0
0.0
50.0
90.0
0
Can be adjusted between 0.0°C
and C.upl parameter.
In order to setting up the parameter access options, specified security
code must be entered. Once the security code has been entered,
AccS parameter can be accessed by using key.
CIR.SET 0.5 +
Programming Mode
Measurement
value
1000
Running Mode
22.0 30.0 29.9 30.0
Pfa
Thermostat probe or line is short circuited
PsC
Thermostat probe not connected, broken or probe faulty.
Error Messages
Measured value is higher than the scale
Measured value is lower than the scale
C.int
Coal
Coal 0.5 -
CIR.SET
NTC Input
t
t
Fan
Fan 0.5 -
t
t
CIRCULATION
Output
If the measurement value is blinking on display,
measured value is out of alarm scale limits.
23.5
Output Table
Initial Value
Hysteresis value for
FAN,
CIRCULATION
and
COAL outputs.
HYS. 2.0
C.dur
C.int
C.dur
---
COAL
LED
CIRCULATION
LED
FAN
LED
COAL output will be active as long as COAL key is pressed while in "Running Mode". In "Programming Mode", provides the
menu selection and increases the parameter value. In "Running Mode", by using together with the SET key, provides the
increases the set value. If pressed continuously, value increases rapidly.
In "Running Mode", indicates the measurement temperature value. In "Programming Mode", indicates the current parameter's
name or parameter's value.
S.cod
Err. Accs.
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
oFF Temperature
Offset Value 0.0
SET
2/2
Parameter access options are determined by this parameter.
If P.no is selected, the parameters are visible but values can
not be changed. If P.YES is selected, values of all parameters
can be changed.
ET1413R-EN-01-170404
In "Programming Mode", provides the parameter selection and decreases the parameter value. In "Running Mode", by using
together with the SET key, provides the decreases the set value. If pressed continuously, value decreases rapidly.
In "Running Mode", provides the set value . In "Programming Mode", provides the configuring to selected parameter value.
In order to configuring a selected parameter, press and hold down to key and perform the desired settings by using
navigation keys.
SET
If key is pressed in "Running Mode", CIRCULATION set value displayed and desired value can
be set by using navigation keys. Initial setpoint value for circulation is 35.0 °C .
if keys are pressed together for 3 seconds,
“Programming Mode” is entered.
if keys are pressed together,
“Running Mode” is entered.
Themperature set
value for
FAN
Time between
Stoking Coal
processes
Upper limit for
circulation set
value
Lower limit for
alarm set
value
Upper limit for
alarm set
value
Can be adjusted between
0.0°C and 120.0°C
Can be adjusted between
0.0°C and 120.0°C
Can be adjusted between 0
and 150 seconds. If set as 0 ,
coAL output is disable.
Can be adjusted between 0.0
and 15.0 minutes. If set as 0.0 ,
coAL output is enable.
Can be adjusted between
-20.0°C and 20.0°C
Can be adjusted between CLoL
parameter and 150.0 °C.
Can be adjusted between 0.0 °C
and A.uPL parameter.
Can be adjusted between A.LoL
parameter and 150.0 °C.
Can be adjusted between
0.1 °C and 20.0°C
COAL
Output
FAN
Output

Other sisel Controllers manuals

sisel ENDA ET4430 User manual

sisel

sisel ENDA ET4430 User manual

sisel ENDA EUP Series User manual

sisel

sisel ENDA EUP Series User manual

sisel ENDA ERPA1 Series User manual

sisel

sisel ENDA ERPA1 Series User manual

sisel ENDA ERFA1-NTC-240 Series User manual

sisel

sisel ENDA ERFA1-NTC-240 Series User manual

sisel ENDA ERFA1 Series User manual

sisel

sisel ENDA ERFA1 Series User manual

Popular Controllers manuals by other brands

rotork FAIRCHILD PAX1 user manual

rotork

rotork FAIRCHILD PAX1 user manual

ABB RELION REM615 Product guide

ABB

ABB RELION REM615 Product guide

Omron G9SP Series manual

Omron

Omron G9SP Series manual

Daikin MicroTech III Operation manuals

Daikin

Daikin MicroTech III Operation manuals

Team Orion VortexR8X Pro instruction manual

Team Orion

Team Orion VortexR8X Pro instruction manual

Masibus 5040 user manual

Masibus

Masibus 5040 user manual

Mitsubishi Electric MELSEC iQ-R Series Reference manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series Reference manual

Panasonic SL-VGU1-EC instruction manual

Panasonic

Panasonic SL-VGU1-EC instruction manual

ARTERY AT32F403A Series quick start guide

ARTERY

ARTERY AT32F403A Series quick start guide

Wallgate WDC200-NX Series product manual

Wallgate

Wallgate WDC200-NX Series product manual

ICP DAS USA WP-5231PM-3GWA-CE7 quick start

ICP DAS USA

ICP DAS USA WP-5231PM-3GWA-CE7 quick start

Flycolor Raptor 390Tower-20A user manual

Flycolor

Flycolor Raptor 390Tower-20A user manual

CLIVET ELFOControl2 Installation, configuration and use manual

CLIVET

CLIVET ELFOControl2 Installation, configuration and use manual

Siemens OZS164 series installation instructions

Siemens

Siemens OZS164 series installation instructions

Fasel Elektronik FCU2000 Series installation instructions

Fasel Elektronik

Fasel Elektronik FCU2000 Series installation instructions

YASKAWA iQpump 7 quick start guide

YASKAWA

YASKAWA iQpump 7 quick start guide

Addonics Technologies ADN1GPX Specification & installation guide

Addonics Technologies

Addonics Technologies ADN1GPX Specification & installation guide

Weishaupt WRSol 1.0 Installation and operating instructions

Weishaupt

Weishaupt WRSol 1.0 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.