SKF Lincoln 84013 User manual

Installation instructions
Model and A
Small reservoir refill filter
Date of issue April 2018
Form number 404044
Version 3

Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Explanation of signal words
for safety . . . . . . . . . . . . . . . . . . . . . . . . 2
Description. . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . .
Installation. . . . . . . . . . . . . . . . . . . . . . . 3
Operation . . . . . . . . . . . . . . . . . . . . . . . . 3
Disassembly and cleaning . . . . . . . . . . 4
Filter cleaning option . . . . . . . . . . . . . .
Filter cleaning option . . . . . . . . . . . . . .
Filter cleaning option . . . . . . . . . . . . . .
Bypass pin replacement. . . . . . . . . . . . 5
Removal . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . .
Filter assembly tips. . . . . . . . . . . . . . . . 5
Individual parts break down and
parts list. . . . . . . . . . . . . . . . . . . . . . . . . 6
Warranty . . . . . . . . . . . . . . . . . . . . . . . . 8
Safety
Read and carefully observe operating
instructions before unpacking and operating
filter. Filter must be operated, maintained
and repaired exclusively by persons familiar
with operating instructions. Local safety
regulations regarding installation, operation
and maintenance must be followed.
Operate filter only after safety
instructions and this service manual are
fully understood.
Explanation of signal
words for safety
NOTE
Emphasizes useful hints and
recommendations as well as
information for efficient and trouble-
free operation.
DANGER
Indicates a dangerous situation that will
lead to death or severe injury if
precautionary measures are ignored.
Specifications
Model Model A
Collapse pressure psi (41,4 bar) psi (41,4 bar)
Screen size mm
Inlet 1/2 in NPTF 1/2 in NPTF
Outlet 1/2 in NPTF 1/2 in NPTF
Maximum working pressure 5 000 psi (344,7 bar) 5 000 psi (344,7 bar)
Maximum flow rate 1 gallon/minute
(3,8 liters/minute)
1.25 gallons/minute
(4,7 liters/minute)
Description
Model and A are grease filters
used to refill small reservoirs of pumps such
as model QuickLub pumps.

NOTE
Filter and A should be
mounted between delivery pump and
grease reservoir being refilled.
Do not exceed maximum flow rate
when filling reservoir. Refer to
Specifications, page 2.
5
4
3
2
1*
6
7
8
9
10
11
12
13
A
B
1*
Installation
1 Shut off all grease flow into
grease reservoir.
2 Apply Teflon-based thread sealant to all
threaded connections.
3 Connect grease delivery pump outlet
hose to 1/2in NPTF refill filter inlet (11).
4 Connect 1/2in NPTF refill filter outlet (12)
to hose leading into grease reservoir.
Fig. 1
Operation
Grease flows through inlet (11) and exits
from outlet (12) under normal conditions
while filtering out impurities exceeding
microns in size ( micron for A)*.
Under such conditions, bypass pin (2) is in
extended position (Fig. 1, A).
Fluid pressure in filter, or differential
pressure, increases as contaminants are
filtered out by filter assembly (1). When
differential pressure from grease filter
exceeds psi (13,8 bar) due to trapped
contaminants, bypass pin (2) retracts into
filter body (8) and fluid bypass is activated,
releasing grease through
outlet (13) (Fig. 1, B).

NOTE
Bypass filter assembly (14) includes
filter element (1) with precision
toleranced to operate in filter body (8).
Sliding cylinder (15) loctited to bypass
filter assembly is one to one match with
filter body. As a consequence, filter
assembly (1) is not available as
service part.
Disassembly of bypass filter
assembly (14) is not recommended,
except in case of bypass pin
replacement.
Use care when handling bypass filter
assembly (14).
DANGER
Do not use mineral spirits without
personal protective equipment.
Failure to comply will result in death
or serious injury.
Disassembly and
cleaning
Release of grease through bypass
outlet (13)(Fig. 1, B, page 3)indicates
bypass filter element assembly (14) should
be removed and cleaned to restore refill filter
to normal operation.
1 Shut off any grease flow to refill filter.
2 Unscrew cap (5).
3 Remove bypass filter
assembly (14, 15) (Fig. 2).
Filter cleaning option 1
1 Submerge bypass filter assembly (14)
in mineral spirits.
2 Brush contaminants from screen of
bypass filter assembly (14).
5
14
15
8
6
2
1
3
Fig. 2
Filter cleaning option 2
1 Using parts washer, direct flow though
rear opening (15).
2 Brush contaminants from screen of
bypass filter assembly (14).
Filter cleaning option 3
Dislodge contaminants from screen of
bypass filter assembly (14) using
compressed air.

NOTE
Allow at least hours for Loctite to
cure before use after assembling bypass
filter assembly (14).
NOTE
Lubricate o-ring (3) prior to assembling
for smooth travel of indicator pin. Leave
o-ring slightly behind grease bypass
slots when placing indicator assembly
into cap.
Bypass pin
replacement
Removal
1 Using 5/32 in t-handle hex wrench,
remove hex screw (6) (Fig. 2, page 4)
from bypass filter assembly (14) via
opening (15).
2 Remove bypass pin (2).
Installation
1 Apply one drop of Loctite to inside
threading of bypass pin (2).
2 Using 5/32 in hex wrench, hand tighten
hex screw until bypass pin (2) is
firmly against filter assembly (1).
3 Place cap (5) back as shown in Fig. 3 and
screw back into filter body. Make sure
indicator is being pushed in while
screwing cap to avoid indicator pin
turning with cap.
4 Verify indicator pin slides freely with no
binding when flush with cap.
Filter assembly tips
1 To aid bypass filter assembly alignment,
insert rod-like tool, such as t-handle hex
wrench, through outlet (11) of filter
body (8) into bypass filter assembly (14)
via spring (7) (Fig. 3).
2 Tighten cap (5) into filter body (8),
periodically depressing bypass pin (2) to
ensure it slides freely within
filter body (8).
11
7
14
5
2
8
Fig. 3

10
9
5
4
1
6
7
8
2
3
11
15
Parts list
Item number Description Part number
Filter element assembly ) )
Bypass pin
O-ring
Gasket
Cap
Hex screw
Spring
Filter body )
Bracket, filling filter*
Washer
Retaining ring
Slide )
Fig. IPB 1*
) Not available as a service part.
) Alternative filter element assembly A ( um).
*Indicates change.

This page left intentionally blank.

skf.com | lincolnindustrial.com
® SKF and Lincoln are registered trademarks of the SKF Group.
© SKF Group
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
April · Form Version
Warranty
The instructions do not contain any
information on the warranty.This can be
found in the General Conditions of Sales,
available at: www.lincolnindustrial.com/
technicalservice or www.skf.com/lubrication.
This manual suits for next models
1
Table of contents
Other SKF Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Pentair
Pentair OMNIFILTER T600R Installation and operation manual

Kraus
Kraus FC-100 installation manual

Atlantic Ultraviolet
Atlantic Ultraviolet Sanitron S50C owner's manual

ELECTROSEA
ELECTROSEA CLEARLINE System CL-430-N1.0 installation manual

Sima
Sima SCC user manual

Cosel
Cosel EAC Series instruction manual