Skope OD330N User manual

OD330N
Service Manual
MAN80213 Rev. 1.4 Apr. 2022
SKOPE Open Deck Cooler

OD330N
SKOPE Open Deck Cooler
Service Manual
MAN80213
Rev. 1.4 Apr. 2022
© 2020 SKOPE Industries Limited. All rights reserved.
SKOPE Industries Limited reserve the right to alter specifications without notice.
is a registered trademark of SKOPE Industries Limited.
SKOPE INDUSTRIES LIMITED
Head Office
PO Box 1091, Christchurch
New Zealand
NZ: 0800 947 5673
E-mail: [email protected]
Website: www.skope.com
Trademark Infringement
The SKOPE trademark on this product is infringed if the owner, for the time being, does
any of the following:
• Applies the trade mark to the product after their state, condition, get-up or packaging
has been altered in any manner
• Alters, removes (including part removal) or obliterates (including part obliteration) the
trade mark on the product
• Applies any other trade mark to the product
• Adds to the product any written material that is likely to damage the reputation of the
trade mark
Notice of the above contractual obligations passes to:
• Successors or assignees of the buyer
• Future owners of the product

SKOPE OD330N
Service Manual CCEP iii
CONTENTS
1 Specifications
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
OD330N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2 Electronic Controller
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Controller Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Buttons and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Service Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
SCS Connect Field App. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Connecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
App Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Faults and Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3 Wiring
Model: OD330N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4 Spare Parts
Cabinet Assembly - OD330N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Refrigeration Cassette Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cabinet Electrics Panel Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Installation
Climate Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Cabinet Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Stabiliser Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Adjusting the Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Gravity Shelf System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
6 Replacement Procedures
Isolating Electrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Removing and Refitting the Cladding . . . . . . . . . . . . . . . . . . . . . .27
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Top Interior Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Bottom Interior Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Shelf Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Cabinet Electrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cabinet Electrics Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Night Blind . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Night Blind Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Refrigeration Cassette. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Before Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Gas Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Leak Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
On-Site Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Hydrocarbon Workshop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Refrigeration Cassette Assembly . . . . . . . . . . . . . . . . . . . . . . . . .35
Cassette Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

SKOPE OD330N
Service Manual CCEP
iv
Cassette Electrics Box Assembly . . . . . . . . . . . . . . . . . . . . . . . . 37
Cassette Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condenser Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Evaporator Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Refrigeration System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Cassette Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
QC Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Electronic Controller Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Replacing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PIR Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Control Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Evaporator Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Condenser Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Air Filter & Condenser Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
7 Troubleshooting
Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

5
SKOPE OD330N
Specifications
Service Manual CCEP
1Specifications
Overview
This cooler utilises Hydrocarbon (HC) R290 as its refrigerant. R290 is a
natural refrigerant that has a very low environmental impact.
Special service requirements are needed as R290 is a flammable
refrigerant.
Safety hazards
The main R290 safety hazards are:
Flammable refrigerant.
Venting of R290 and compressor oil.
Asphyxiation.
SKOPE does NOT recommend performing hazardous activities on the
refrigeration system.

6Specifications
Service Manual CCEP
SKOPE OD330N
Models
This service manual is applicable to the SKOPE coolers detailed below.
OD330N Cabinet
Refrigeration Unit
Model Description Type
OD330N Free-standing O33CLN
Description Free-standing
Type O33CLN
Construction
Insulation 40mm thick, polyurethane foam. Cyclo-iso Pentane
blowing agent: C5H10/C5H12
Doors n.a.
Fitted with manual night blind
Dimensions External Internal
Height 1300mm 776-837mm
Width 890mm 796mm
Depth 740mm (includes 28mm stand-off) 432-598mm
Floor area 0.66m2 (includes 28mm stand-off)
Internal volume 355 litres
Shelves
2 adjustable angle, adjustable height shelves + 1 angled,
fixed in place bottom shelf. Fitted with gravity feed system
and shelf lights
Product loading
3 layers of 600ml PET bottles. Top shelf: 10 facings x 4
deep, middle shelf: 10 facings x 5 deep, bottom shelf: 10
facings x 6 deep. 150 per cabinet
Operating conditions
Max operating temp. 25°C @ 60% RH (Climatic Class 3)
Cabinet temp. range 0°C to 5°C
Electrical 220-240 Volts a.c. 50 Hz, single phase supply
Total run Amps 3.0 Amps (includes unit 2.7 Amps)
GEMS energy
consumption 6.6 kWh/day
Energy star rating TBC stars
Sign lighting n.a.
Internal lighting LED internal cabinet illumination (top and bottom) and
shelf lighting
Description R290 (hydrocarbon) Open Deck Coca-Cola Global
cassette
Unit model UBHENI-0014
Compressor Wanbao FN90M
Controller SCS Connect
Nominal capacity 740 Watts
Refrigerant R290 / 85g

7
SKOPE OD330N
Electronic Controller
Service Manual CCEP
2Electronic Controller
Overview
The cooler is fitted with an SCS Connect electronic controller. The controller
located behind the front kick panel.
The controller is pre-programmed. SKOPE does not recommend that
settings be changed unless it is absolutely necessary. To ensure efficient
operation, the controller automatically forces a defrost cycle when required.
Controller servicing can be performed via the controller faceplate, or the
SCS Connect Field app.
IMPORTANT
The controller must only be adjusted by an authorised service
agent.

8Electronic Controller
Service Manual CCEP
SKOPE OD330N
Controller Faceplate
Buttons and
Display The faceplate includes the front display panel and interface buttons.
Service Mode Service mode can be accessed and used via the controller faceplate, refer
to Wellington Drive Technologies documentation for further information.
Note: A 9 digit pin code is required to access service mode via the controller
buttons. Contact your User Manager to receive your activation code.
There are 5 main service mode categories when accessing and using
service mode via the controller faceplate:
Parameters
Provides access and editing of individual controller parameters.
It is not recommended that parameters are changed unless absolutely
necessary. If incorrect parameter settings are suspected, reload the
complete parameter set.
Reset
Returns the controller back to factory or default settings.
12 3 4 5
8 7
11
10
96
No. Description
1Night Mode: Indicator. On during cooler night mode.
2
Display: Indicator. Digital display of cabinet air temperature or messages.
The temperature is what the sensor inside the cooler detects, and not
necessarily the product temperature. However, they may be very close
depending on how the controller is set to sense temperature.
3
Light Switch - Night Mode (back/abort): Button. Press to switch the lights
on or off. Press and hold to switch cooler between day and night mode. Used
during programming.
4Up: Button. Used for programming.
5Bluetooth: Indicator. On when ready to connect to a device. Flashing when
connected to a device.
6Defrost Cycle (next/enter): Button. Press and hold to initiate manual defrost.
Used during programming.
7Down: Button. Used for programming.
8Fault - Alarm: Indicator. On during fault or alarm. Note: Alarm message is
also shown on the display during alarm.
9Compressor: Indicator. On when the compressor is running.
10 Defrost Mode: Indicator. On during defrost cycle.
11 Fan: Indicator. ON when fans running.

9
SKOPE OD330N
Electronic Controller
Service Manual CCEP
Manual test
Allows inspection of input values from sensors, and check the effects of
output adjustments to peripherals, and to run preset test routines.
Statistics
Displays logged values and event counts to assist with fine tuning and
diagnostics.
About
Lists the properties of the refrigeration system and the controller, including
cooler model codes, firmware, hardware and software versions.

10 Electronic Controller
Service Manual CCEP
SKOPE OD330N
SCS Connect Field App
Connecting The SCS connect field app allows authorised Service Technicians wireless
access to the controller from mobile devices with Bluetooth capability. The
app provides information on data logging, alarm notification and diagnostic
control.
To install the SCS connect field app
To connect to a controller
1. Download and install the Connect Field app from Google Play or Apple Store
(search for “scs wellington” to find it).
2. When you first run the app, you will be requested to enter an activation code.
Contact your User Manager to receive your activation code (you must be
connected to the internet at the time of activation).
Your activation code is unique to you, and should NEVER be shared with
anyone else, as it determines your personal access level for the app. The
same code will give you access to all SCS apps you are authorised to use.
3. Once activation is complete, you must define a 4-digit PIN code. This can be
any code unique to you. Each time you start the app, you will be required to
enter this same PIN code. This is to prevent other people accessing the app
from unlocked phones.
4. You can see which databases you are activated against from the “Settings”
screen. You can be activated to more than one database at the same time.
Simply select ACTIVATE ANOTHER DATABASE, and enter the new
databases unique activation code, as in Step 2.
1. Check that the Bluetooth logo on the top right of the controller faceplate is lit,
indicating that the controller is ready to connect to a device.
Note: A flashing Bluetooth logo indicates that the controller is currently
connected to a device.
2. Open the SCS connect field app.
3. Select a controller to connect to from the list of visible controllers.
Note: This list is filtered by your activation permissions, so devices you are
not authorised to connect to will not be displayed.
4. Select ‘connect’ to connect to the controller.
5. Check that the Bluetooth logo on the top right of the controller faceplate is
flashing, indicating that the controller is connected.

11
SKOPE OD330N
Electronic Controller
Service Manual CCEP
App
Categories Various options are available in the app menu to provide information about
the connected controller and its cooler.
Home screen
The home screen shows a graphic representation of the current state of the
cooler being controlled.
Output control
Provides control of the controller input sensors and switches, and output
relays.
Edit parameters
Provides access and editing of individual controller parameters.
Note: Parameter changes must be recorded on warranty/job card.
It is not recommended that parameters are changed unless absolutely
necessary. If incorrect parameter settings are suspected, reload the
complete parameter set. Note: Updated parameters are not applied until
DISCONNECT has been selected from the menu (after loading new
parameter set).
Load parameter file
Allows reloading of cooler default parameter set or changing to new
parameter set. Note: Updated parameters may not be applied until
DISCONNECT has been selected from the menu (after loading new
parameter set).
Statistics
Information from the past seven days on cooler activity including
temperatures, door openings and alarms.
SCS info
Controller version and cooler asset information.
SCS setup
Add or change SCS info (see above).
Disconnect
Disconnect from currently connected controller.
Settings
Change app general settings.

12 Electronic Controller
Service Manual CCEP
SKOPE OD330N
Faults and Alarms
The following table explains faults and alarms that the electronic controller may log and display.
If a fault occurs, the fault - alarm indicator is lit on the controller faceplate, but no message is
displayed. Faults do not affect product temperature, and require no action from the shop owner.
Alarms are logged and the alarm message is displayed on the controller faceplate. Alarms may
result in abnormal product temperature.
Some faults and alarms can be cleared by the shop owner, and others can only be cleared by a
service technician.
If the cabinet is connected to the power supply and has warm product, check the SCS Connect
Field App for active fault or alarm, and investigate. If the cabinet does not have an active fault or
alarm, check the app statistics to determine if and when the controller signalled a fault or alarm.
Refer to the tables below for faults and alarm descriptions and possible causes and actions.
Faults (alarm indicator lit - no message displayed)
Description Possible root cause
Over-voltage protection
The maximum allowable mains supply voltage has been exceeded. The
cabinet has temporarily shut down to prevent damage and will restart
once the supply voltage decreases.
- should be a one off; if continues:
- line voltage / rural
- voltage setting parameter
- controller
Under-voltage protection
The mains supply voltage has dropped below the minimum allowable
level. The cabinet has temporarily shut down to prevent damage and
will restart once the supply voltage increases.
- should be a one off; if continues:
- power supply overloaded / multibox
- line voltage / rural.
- voltage setting parameter
- controller
High condensing temperature protection
The system was operating at an elevated temperature and has
temporarily shut down to prevent damage. Extended operation in this
condition may result in ALARM 15, increased energy consumption and
a reduction in cabinet life. This alarm may be caused by very high
ambient temperature.
NO swap cassette required
- condenser not clean
- poor installation / ventilation
- condenser fan motor / blade
- controller
Excessive compressor cycling protection
The system has been turning on and off too frequently.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
- poor installation / ventilation
- cabinet / cassette gasket seals leaking
- door not self closing / gasket leaking
- product hot / blocking cabinet airflow
- overloaded from excess door openings /
ambient
- fan motor / blade (condenser / evaporator)
- controller
- compressor / gas leak = SWAP cassette

13
SKOPE OD330N
Electronic Controller
Service Manual CCEP
Alarms
Code Description Possible root cause
8Estimated product temperature below allowable range
The estimated product temperature has been below the
allowable range for longer than the permissible time. Potential
causes are: an empty or partially filled cabinet, or low ambient
temperature.
- low ambient
- App settings
- controller
9Estimated product temperature above allowable range
The estimated product temperature has been above the
allowable range for longer than the permissible time. Potential
causes are: excessive door openings, door being left open, or
warm product loaded into cabinet.
NO Swap cassette required to be taken (but may
be required as fault could still be with sealed
refrigeration system)
- condenser blocked
- poor installation / ventilation
- frozen blocked evap coil
- cassette gasket leaking (to cabinet seal / lid seal)
-door leaking air (bad gasket / door not self
closing)
- product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- App settings
- controller
- compressor / gas leak = arrange SWAP cassette
15
Excessive condensing temperature protection
The system was operating at an excessive temperature and
has shut down to prevent permanent damage. This alarm may
occur due to very high ambient temperature.
NO swap cassette required
- condenser not clean
- poor installation / ventilation
- condenser fan motor / blade
- controller
17
Control probe failure
A critical system sensor has failed and the cabinet can no
longer operate.
NO swap cassette required
- control Probe / circuit
- controller
18
Electrical over-current protection activated
The compressor was drawing too much current and has shut
down to prevent permanent damage.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
- poor installation / ventilation
- cabinet / cassette gasket seals leaking
- door not self closing / gasket leaking
-product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- controller
- compressor / gas leak = SWAP cassette
19
Failed to reach set temperature
The refrigeration system has been operating continuously for a
long period without reaching the set temperature.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
- poor installation / ventilation
- frozen blocked evap coil
- cabinet seal leaking / door / cassette
-product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- controller
- compressor / gas leak = SWAP cassette
20
Over cooling product
The internal temperature is too low. The system has
temporarily shut down until the temperature has returned to
normal. This can occur if the set temperature has been raised
by a large amount.
- confirm if really too cold; change parameters
accordingly
22 Evaporator fan over-current protection
The current supplied to the evaporator fan motor is too high.
NO swap cassette required
- faulty fan motor
- fan blade fault (imbalance / debris / blockage)
- controller
Continued over page
23 Condenser fan over-current protection
The current supplied to the condenser fan motor is too high.
NO swap cassette required
- faulty fan motor
- fan blade fault (imbalance / debris / blockage)
- controller

14 Electronic Controller
Service Manual CCEP
SKOPE OD330N
24 Controller communication error
Controller has lost communication channels.
- App
- controller / circuit
25 Controller update failed
Controller update could not be completed.
- App
- controller / circuit
26 Controller hardware failure
Controller hardware has failed.
- App
- controller / circuit
27
Probe failure
A non-critical system probe has failed. The cabinet will
continue to operate with partial function but requires service.
NO swap cassette required
- Evap probe / connections
- controller
28 No downward tendency
The temperature is no longer decreasing.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
-poor installation / ventilation
- cabinet / cassette gasket seals leaking
- door not self closing / gasket leaking
- product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- controller
-compressor / gas leak = SWAP cassette
29
Compressor cutting out
The compressor cut out on its internal protection or pressure
switch.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
-poor installation / ventilation
- cabinet seal leaking / door / cassette
- product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- controller
- compressor / gas leak = SWAP cassette
30 Excessive automatic defrosting
The system is automatically defrosting too frequently.
Take spare cassette in case refrigeration system
fault.
- door not self closing / gasket leaking
- Evaporator probe
- Evaporator motor / fan
- controller
- compressor / gas leak = SWAP cassette
31 Compressor stalling
The compressor is stalling on start up.
Take spare cassette in case refrigeration system
fault.
- condenser blocked
-poor installation / ventilation
- cabinet / cassette gasket seals leaking
- door not self closing / gasket leaking
- product hot / blocking cabinet airflow
- overloaded from excess door openings / ambient
- fan motor / blade (condenser / evaporator)
- controller
- compressor / gas leak = SWAP cassette
Code Description Possible root cause

15
SKOPE OD330N
Wiring
Service Manual CCEP
3Wiring
Model: OD330N
BU
BN
BN
S2-2 P2-2
P2-1 S2-1
S1-1 P1-1
P1-N S1-N
T1-1
BN
BU
T1-N
BU
OG
RD
BN
P7 S7
WH
BK
WH
P6 S6
WH
BK
BU
BU
P8 S8
BU
BU
Condenser Fan
Evaporator Fan
BN BU
BK
S3-4 P3-4
S3-2 P3-2
S4-4 P4-4
S4-2 P4-2
P3-1 S3-1
P4-1 S4-1
S5-2 P5-2
T2-2 LED Ballast
N
L
+
-
T5-4,
5 & 6
T5-1,
2 & 3
T4-1
BN
P5-1 S5-1
BU
BU
BU
BU
Appliance
Sensor
Evaporator
Sensor
EMC Filter
BN
BN
L
GNYE
GNYE
E
BK
WH WH
T2-3 &
T3-2
WH
WH/BK
Bottom
Shelf Light
WH
WH/BK
Middle
Shelf Light
WH
WH/BK
Top
Shelf Light
5
63
1
N
L
Overl oad
Protector
2
Ru n
Capacitor
Start
Capacitor
PTC
Starter
AM
C
Co mpr ess or
Sanden Compressor
SRACA 6402
T4-2
BU
RD
BK
RD
BK
T6-1
T6-2
Upper
Cabinet Light
Lower
Cabinet Light
BU
BK
BU
BN
BK
WH
BK
Curtain
Switch
T7-2
T7-3
T7-1
T7-2
BK
WH
BK
WH
BU
BN
WDTL
SCS
Controller
L N
C
R
R
DI1
0V AD1
DI2
0V AD2
DI3
0V AD3
DI4
5V
0V
AD4
DI5
0V
LED1
LED2
LED3
AD5
SSR
S1
S2
SSR
Comp.
BK
PIR Sensor
(Reach-in)
RD
BN
P9 S9
WH
BK
Condenser
Sensor
RD
BK
BK
WH
WH
P10 S10
BK
BN S11-2 P11-2
P11-1 S11-1
BU
BU
T2-1 &
T3-1
BN BN BU
Cabinet Top
Element
Only presentin some models –
refer to the service manual
B
BU
BN
BN
S2-2 P2-2
P2-1 S2-1
S1-1 P1-1
P1-N S1-N
T1-1
BN
BU
T1-N
BU
OG
RD
BN
P7 S7
WH
BK
WH
P6 S6
WH
BK
BU
BU
P8 S8
BU
BU
Condenser Fan
Evaporator Fan
BN BU
BK
S3-4 P3-4
S3-2 P3-2
S4-4 P4-4
S4-2 P4-2
P3-1 S3-1
P4-1 S4-1
S5-2 P5-2
T2-2 LED Ballast
N
L
+
-
T5-4,
5 & 6
T5-1,
2 & 3
T4-1
BN
P5-1 S5-1
BU
BU
BU
BU
Appliance
Sensor
Evaporator
Sensor
EMC Filter
BN
BN
L
GNYE
GNYE
E
BK
WH WH
T2-3 &
T3-2
WH
WH/BK
Bottom
Shelf Light
WH
WH/BK
Middle
Shelf Light
WH
WH/BK
Top
Shelf Light
5
63
1
N
L
Overl oad
Protector
2
Ru n
Capacitor
Start
Capacitor
PTC
Starter
AM
C
Co mpr ess or
Sanden Compressor
SRACA 6402
T4-2
BU
RD
BK
RD
BK
T6-1
T6-2
Upper
Cabinet Light
Lower
Cabinet Light
BU
BK
BU
BN
BK
WH
BK
Curtain
Switch
T7-2
T7-3
T7-1
T7-2
BK
WH
BK
WH
BU
BN
WDTL
SCS
Controller
L N
C
R
R
DI1
0V AD1
DI2
0V AD2
DI3
0V AD3
DI4
5V
0V
AD4
DI5
0V
LED1
LED2
LED3
AD5
SSR
S1
S2
SSR
Comp.
BK
PIR Sensor
(Reach-in)
RD
BN
P9 S9
WH
BK
Condenser
Sensor
RD
BK
BK
WH
WH
P10 S10
BK
BN S11-2 P11-2
P11-1 S11-1
BU
BU
T2-1 &
T3-1
BN BN BU
Cabinet Top
Element
Only presentin some models –
refer to the service manual
LEGEND
T1 Unit Junction Box Terminal S3/P3 Condenser Fan Motor Socket/Plug (Red 4-Way)
T2 Cabinet Wiring Tray Terminal (RHS) S4/P4 Evaporator Fan Motor Socket/Plug (White 4-Way)
T3 Cabinet Wiring Tray Terminal (RHS) S5/P5 Lighting Socket/Plug (on Unit) (White 3-Way)
T4 Cabinet Wiring Tray Terminal (LHS) S6/P6 Door/Curtain Switch Socket (on Unit) (White 2-Way)
T5 Cabinet Wiring Tray Terminal (LHS) S7/P7 Evaporator Sensor Socket/Plug (on Unit) (Black 2-Way)
T6 Cabinet Light Terminal S8/P8 Appliance Sensor Socket/Plug (on Unit) (Blue 2-Way)
T7 Curtain Switch/Ctrl Probe Junction S9/P9 Condenser Sensor Socket/Plug (on Unit) (Red 2-Way)
S1/P1 IEC Isolation Socket/Plug S10/P10 Reach-in Sensor Socket/Plug (on Unit) (Blue 4-Way)
S2/P2 Compressor Socket/Plug (Blue 4-Way) - -
OTerminal block Terminal >> Plug & Socket
WIRE COLOURS
BK Black
BN Brown
RD Red
OG Orange
GN Green
BU Blue
GY Grey
WH White
GNYE Green-Yellow
Based upon IEC 757 Standard

16 Spare Parts
Service Manual CCEP
SKOPE OD330N
4Spare Parts
Cabinet Assembly - OD330N
Parts — Cabinet OD330N
Item Description SKOPE Part No. CCEP-AU Part No. CCEP-NZ Part No.
1LH side cladding O332/009L
2RH side cladding O332/009R
3LH & RH electrics panel cover O230C/N02A 120085662
4
Night blind cover - White PLM11935-FD
Night blind cover - Black PLM11935-49
Night blind cover plastic rivet PLM10437BK 120085751
5
Sign insert assembly O331/S22
Sign insert holder (black) PLE11375 120085704
Sign insert cover (clear) PLY11504 120085777
6Front upstand PLM11280 120085707
7
Front kick panel assembly - White SXX11936-FD
Front kick panel assembly - Storm satin
(grey) SXX11936-EX
8Top shelf - White O332/592C-32
Top Shelf - Black O332/592C-49
3031 3032 3132
3
29
33
1
37
20
29 33
38
25
3
25
25
2
35
21
10
28
40
9
18
13
34
26
8
36
23
27
22
17
16
11
12
4
39
5
7
6
19
1
1
0
11
12
13
16
17
18
19
2
20
21
22
23
25
25
25
26
27
28
29
29
3
3
30
30
31
31
32
32
33
33
34
35
36
3
7
38
39
4
4
0
5
6
7
8
9

17
SKOPE OD330N
Spare Parts
Service Manual CCEP
9Top shelf LH adjustment bracket STY11601L
10 Top shelf LH bracket STY10956L
11 Top shelf RH adjustment bracket STY11601R
12 Top shelf RH bracket STY10956R
13 Middle shelf - White O332/592B-32
Middle shelf - Black O332/592B-49
14 Middle shelf LH adjustment bracket STY11600L
15 Middle shelf LH bracket STY10955L
16 Middle shelf RH adjustment bracket STY11600R
17 Middle shelf RH bracket STY10955R
18 Bottom shelf - White O332/592A-32
Bottom shelf - Black O332/592A-49
19 Shelf matting kit (for all shelves)CCEP source - MFT 120085769
20 LH side window GLA11278L 120085428
21 RH side window GLA11278R 120085774
22 Night blind SXX11277 120085778
Night blind spigot bush PLM10342 120083591
23
Night blind holder with switch - RH White O232/748A-32
Night blind holder with switch - RH Black O232/748A-49
Switch HB0074091444 120073424
Screw for night blind switch - Black FAS11917
Nut for night blind switch - Black FAS11918
24 Night blind holder - LH O331/747
25 Shelf light ELL11028 120085001
26
Top interior light assembly O332/L01
Top interior light ELL11897
Light clip SXX11778
27
Bottom interior light assembly O332/L99
Bottom interior light ELL11897
Bottom interior light cover PLM11283 120085776
Screw cap - Black PLM10438BK 120083011
Light clip SXX11778
28 Return air grille O332/586-32
Return air grille O332/586-49
29 Rear spacer RUM4105 120083597
30 Castor SXX10289 120076006
31 Wheel SXX7520 120072019
32 Stabiliser foot SXX10970 120084923
33 Handle HAN0000
34 Honeycomb air guide PLX10305 120082962
35 Lifting arm O230C/329
36 PIR sensor O332N/X03
37 Cabinet electrics panel assembly - LH O230F/G29L 120085663
38 Cabinet electrics panel assembly - RH O232F/G29R
39 Condenser filter FIL11960
40 Refrigeration cassette assembly HB0070834626(U
BHENI-0014)
Item Description SKOPE Part No. CCEP-AU Part No. CCEP-NZ Part No.

18 Spare Parts
Service Manual CCEP
SKOPE OD330N
Refrigeration Cassette Assembly
15
3
12
21
13
19
17
20
21
16
18
6
11
14
28
27
5
22
25
23
26
24
10
7
8
9
1
2
1
10
11
12
13
14
15
17
18
19
2
20
21
21
22
23
2
4
25
26
27
28
3
5
6
8
9

19
SKOPE OD330N
Spare Parts
Service Manual CCEP
Parts — Refrigeration Cassette
Item Description SKOPE Part No. CCEP-AU Part No. CCEP-NZ Part No.
0Cassette assembly HB0070834626(U
BHENI-0014)
1Cassette plastic top cover HB0070201535H
2Cassette gasket seal HB0070201441 120075985
3Cassette plastic bottom HB0070201536G 120086254
4Cassette mesh grille HB0070108541 120080742
5Evaporator tub HB0070508351A 120084138
6Evaporator coil HB0070702822
7Evaporator fan motor ELM11309 120084738
Evaporator fan motor extension flex HB0070401110 120086264
8Evaporator fan blade HB0074000311 120076300
9Fan guard HB0070112818A 120085720
10 Evaporator fan wall ring HB0070109669
11 Condenser coil HB0070702676 120086253
12 Condenser fan motor ELM11309 120084738
13 Condenser fan blade HB0074000313 120084275
14 Suction line assembly HB0070702677A 120086261
15 Process tube HB0070701601 120086235
16 Discharge line assembly HB0070702823
17 Compressor HB0074000848 120086228
Compressor flex HB0070402527 120086226
18 Drier HB0074180006 120086202
19 Drain tube HB0070209132
20 Spiggot for drain tube HB0070203591 120086204
21 Drain tray leg HB0070203473 120084126
22 Cassette electrics box assembly HB0070834968
Controller base plate HB0070203474G 120086229
23 Cassette electrics box front cover HB0070201467C 120084120
24 Power cord retainer HB0070208656 120086244
25 Controller cover plate HB0070208641 120086239
26 SCS Connect electronic controller ELZ11488 120084745
27 Defrost probe HB0070400506 120084135
28 Condenser probe HB0070401693B 120086203
29 Appliance probe (not pictured) HB0070400542 120083608

20 Spare Parts
Service Manual CCEP
SKOPE OD330N
Cabinet Electrics Panel Assemblies
Parts — Cabinet Electrics Panel Assemblies
Item Description SKOPE Part No. CCEP-AU Part No. CCEP-NZ Part No.
0LH cabinet electrics panel assembly O230F/G29L 120085663
0RH cabinet electrics panel assembly O232F/G29R
1LED power supply O230F/K08
2EMI filter/surge protector ELZ10136 120080839
-Mains power cord (not pictured) O230F/E53
-Cabinet to unit flex (not pictured) FLX11210
Unit to cabinet power flex (not pictured) O332N/X02
Unit to cabinet sensor flex (not pictured) FLX11208
Unit compartment LED flex (not pictured) O331/W64
Bottom light flex (not pictured) O331/X02 120085749
Shelf light flex (not pictured) FLX10960
Top Light flex (not pictured) O230F/W63
1
2
Other manuals for OD330N
1
Table of contents
Other Skope Commercial Food Equipment manuals
Popular Commercial Food Equipment manuals by other brands

Angelo Po
Angelo Po 0G1CP1G Use and installation manual

OFFCAR
OFFCAR Stile 980 Series Instruction manual for installation, maintenance and use

Lincat
Lincat Lynx 400 LBR instructions

Vulcan-Hart
Vulcan-Hart VSX5G manual

Fiap
Fiap profiwork 1994 manual

Belshaw Brothers
Belshaw Brothers EZMelt 18 Operator's manual

Chocolate World
Chocolate World CW24 Use and maintenance manual

Diamond
Diamond DPA/BSV15 Installation, operating and maintenance manual

Lotus
Lotus CP-94G Installation and operating instructions

Roeder
Roeder BK98GPLA8 Installation and use instruction

Crown
Crown DLTM-40 Installation & operation manual

ScanBox
ScanBox Ergo Line Hot user manual