manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Smart Bridge
  6. •
  7. Security Sensor
  8. •
  9. Smart Bridge Quick 9500N-000 User manual

Smart Bridge Quick 9500N-000 User manual

【Quick Install Guide : Smart Bridge 9500N-000 Quick Temperature Detector】
1 QIG-QTM 0.0.1-001 08-2020 / v1.1
Product Contents
The contents of the 9500N-000 quick temperature detector includes the
following objects:
-9500N-000 quick temperature detector x1 set
-USB power cord x 1 cable
-USB Power Supply 110/240V to 5V USB output x 1 set
-3M double-sided sticker x1
Prepare Before Use
1. Please take out the quick temperature detector and 3M double-sided
glue sticker then paste to the position you want. Plug in the USB
power cord and connect to the power supply.
2. After power-on, OLED-screen will display the booting- screen about 5
to 10 seconds. Enter to temperature measurement mode directly
after the display is off.
Settings
Three different mode for setting temperature、temperature unit and alarm
sound sequentially. Holding the button with different time for different
setting:
1. Alarm temperature adjustment: Hold the button then release it while OLED
displays 3~5 to enter the setting. (Default: 37.5℃)
2. Celsius/Fahrenheit adjustment: Hold the button then release it while OLED
displays 6~9 to enter the setting. (Default: Celsius)
3. Alarm sound adjustment: Hold the button then release it while OLED
displays 9~11 to enter the setting. (Default: Speaker On)
Setup:
1. Press the side-button until OLED displays “3”then release. Display such
as 37.0, press again to 37.1 and so on. When the system detects no
further pressing within 3 seconds, the current temperature the alarm
temperature threshold. (Figure 1)
2. Press the side-button until OLED displays “6” then release. Display such
as ℃and press again for ℉. When the system detects no further
pressing within 3 seconds, use the current temperature unit. (Figure 2)
3. Press the side-button until OLED displays “9”then release. Display such
as “Speaker On”and press again for “Speaker Off”. When the system
detects no further pressing within 3 seconds, use the current alarm
sound setting. (Figure 3)
Measurement
1. The forehead is about 30-50 cm from the center of
the sensor.
2. Temperature measurements can be obtained 3 seconds later
(Figure 4)
3. Get your temperature correctly and you'll hear Bi sound
If the temperature is measured higher than setting
value, you will hear the “Bi Bi Bi”sound.
If the temperature is lower than setting value, you will
only hear a beep.
37.0
37.1
37.2
37.3
37.4
37.5
37.6
37.7
37.8
37.9
38.0
Figure1
Figure2
Figure3
【Quick Install Guide : Smart Bridge 9500N-000 Quick Temperature Detector】
2 QIG-QTM 0.0.1-001 08-2020 / v1.1
Remarks
1. The product of quick temperature detector cannot work under the
sunshine. For outdoor usage, it is recommended to set up a scaffold,
block ingenuity to the sun. When the sun shines directly, the hair quickly
absorbs the sun energy. Therefore the body temperature will pull up and,
do not measure the temperature at this time.
2. The ambient temperature need to be controlled between 15 to 35
degrees Celsius. Too low, or too high, measured body temperature has
been unable to refer. Please control the ambient temperature in order to
get the correct body temperature.
3. Different environment: When a person enters the room from outside, if
the temperature gap between the two is too large, it needs to be delayed
by about 5 minutes before testing temperature. For example, outdoor is
35 degrees Celsius, directly into the room for 25 degrees Celsius
condition, Detect temperature immediately, the temperature will be
incorrect.
4. For fast temperature detector, it is recommended to power-on 5-10
minutes for warn up the system. Then, the detector could be work
normally.
5. This product is mainly used to detect the temperature of the forehead.
Other parts of the human body, the test will be incorrect. Chinese
website: http://www.smartbridge-info.com / English Website:
http://www.smartbridge-tech.com

Other Smart Bridge Security Sensor manuals

Smart Bridge 9500N-100 User manual

Smart Bridge

Smart Bridge 9500N-100 User manual

Smart Bridge 9500N-000 User manual

Smart Bridge

Smart Bridge 9500N-000 User manual

Smart Bridge 8811S-GW&9202N-RF User manual

Smart Bridge

Smart Bridge 8811S-GW&9202N-RF User manual

Popular Security Sensor manuals by other brands

Aritech EV400-PLUS Series quick start guide

Aritech

Aritech EV400-PLUS Series quick start guide

Hytronik Dual Sense HIM17 quick start guide

Hytronik

Hytronik Dual Sense HIM17 quick start guide

LEGRAND 488 21 manual

LEGRAND

LEGRAND 488 21 manual

Tongdy MSD Series user manual

Tongdy

Tongdy MSD Series user manual

AGFA DX-D 40C user manual

AGFA

AGFA DX-D 40C user manual

AMC SMILE 18 manual

AMC

AMC SMILE 18 manual

ConTech Lighting REXA Series installation instructions

ConTech Lighting

ConTech Lighting REXA Series installation instructions

Homematic IP HmIPW-SMI55 Installating instruction and operating manual

Homematic IP

Homematic IP HmIPW-SMI55 Installating instruction and operating manual

FlowLine EchoBeam LR80 Series manual

FlowLine

FlowLine EchoBeam LR80 Series manual

Nexa SP-816 manual

Nexa

Nexa SP-816 manual

FLIR VP50-2 user manual

FLIR

FLIR VP50-2 user manual

Videofied ITR110 installation instructions

Videofied

Videofied ITR110 installation instructions

DAITEM SH195AX installation manual

DAITEM

DAITEM SH195AX installation manual

Varian ProStar 363 Driver manual

Varian

Varian ProStar 363 Driver manual

LEGRAND 845 06 manual

LEGRAND

LEGRAND 845 06 manual

New Cosmos Electric KD-12O instruction manual

New Cosmos Electric

New Cosmos Electric KD-12O instruction manual

IME Milesight WS303 user guide

IME

IME Milesight WS303 user guide

Dräger X-AM 5000 Instructions for use

Dräger

Dräger X-AM 5000 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.