Sounder and Ceiling Beacon
Installation Guide
Part number Product description
SC-33-0110-0001-99
SC-33-0120-0001-99
SC-33-0210-0001-99
SC-33-0220-0001-99
SmartCell RED Sounder and Ceiling
Beacon (VAD RED Flash)
SmartCell RED Sounder and Ceiling
Beacon (VAD WHITE Flash)
SmartCell WHITE Sounder and Ceiling
Beacon (VAD RED Flash)
SmartCell WHITE Sounder and Ceiling
Beacon (VAD WHITE Flash)
1Pre installation
Sounder and ceiling beacon
2 Components
Mounting plate2
1
!Installation must conform to applicable local installation codes and
should only be installed by a fully trained competent person.
This device contains electronics that may be susceptible to damage
from Electrostatic Discharge (ESD). Take appropriate precautions
when handling electronic boards.
The use of a non-metallic spacer should be considered if mounting
the device on to a metal surface.
This device is suitable for ceiling mounting only. Wall mounted
variants are also available.
*When batteries are not supplied, only fit specified batteries.
Batteries (not included in some regions*)
3
5 Fit batteries
When fitting / replacing batteries, observe correct polarity, using only
specified batteries.
6 Configuration
ER14500AA
ER14500AA
+
-
+
-
ER14500AA+
-
The device must now be added (programmed) to the control panel.
Device powering
Method 1
Magnet application
Method 2
Via computer
Method 3
4 Fix mounting plate
When fixing to the ceiling, all four fixing positions should be used to
ensure a firm fixing.
Use suitable fasteners and
fixings. 60 mm
60 mm
Where existing electrical
mounting boxes are present,
two fixing positions may be
used.
3 Remove mounting plate
Remove the mounting plate by turning the device ANTICLOCKWISE, to
release it from the mounting plate.
OBSERVE BATTERY
POLARITY!
!
3x ER14505M
LITHIUM 3.6V
©2021 EMS Ltd. All rights reserved. Page 1 of 2 TSD108-0001-99 (Issue 4) 25/08/2021 AJM
2
13
To ensure correct operation, products must be used within the
specified environmental operating conditions.
Refer to the programming manual
for full programming details.
SmartCell panel = TSD155
SmartCell WZM = MK067
0017A3
(B)
(A)
Operating temperature -10 to +55 °C
Storage temperature
With batteries -10 to +30 °C
Without batteries -10 to +55 °C
Humidity 0 to 95% noncondensing
Location Type B: for indoor/outdoor use
IP rating IP33
Supply 3 x ER14505M 3.6 V lithium thionyl chloride
batteries (Fanso or Titus)
CAUTION!
Operating voltage 2.7 to 3.65 VDC
Current consumption 0.32 A max.
Power consumption 0.8 W max.
Operating frequency 868 MHz
Output transmitter power 14 dBm / 25 mW
Signalling protocol X5
Flash Rate 0.5 Hz (1 flash, every 2 seconds)
Beacon coverage C-3-12 (WHITE flash) / C-3-9.5 (RED flash)
Sounder output 92 dB(A) at 1 m max.
For full sounder output information, refer to the Sounder Data doc (MK103).
Dimensions (Ø x D) 110 x 79 mm
Approved to
EN54-3:2001. Incorporating amendments nos. 1 and 2.
Fire detection and fire alarm systems.
Part 3: fire alarm devices - sounders.
EN54-13:2005. Fire detection and fire alarm systems.
Part 13: compatibility assessment of system
components.
EN54-23:2010. Fire detection and fire alarm systems.
Part 23: fire alarm devices. Visual alarm devices.
EN54-25:2008. Incorporating corrigenda september
2010 and march 2012. Fire detection and fire alarm
systems.
Part 25: components using radio links.
European Union
EMS declares that the radio equipment type
directives
SmartCell Sounder & Ceiling Beacon is in compliance
with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following
internet address: www.mysmartcell.com
2012/19/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly manner according to your local regulations.
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul. Kolejowa 24.
39-100 Ropczyce, Poland
Year of manufacture See devices serial number label
Certification
Certification body
CPR DoP 0359-CPR-00428
19
0905
Specification
Reassemble the device as shown below.
8 Completing the installation
Device unlocking
If the device has been locked, an
Allen key will be required for
unlocking.
Depress the locking mechanism,
by inserting the Allen key, or
similar, into the device’s cavity
and pushing (A).
Simultaneously twist the device
anti-clockwise to release (B).
IMPORTANT
!
The device should be tested upon installation, in accordance with local
requirements.
Testing should only be carried out by a fully trained competent person.
Regulatory information
7 Optional device locking
The device includes an optional locking mechanism.
Remove the thin section of plastic shown below.
Once locked, the Allen key will be required
to unlock the device.
©2021 EMS Ltd. All rights reserved. Page 1 of 2 TSD108-0001-99 (Issue 4) 25/08/2021 AJM ©2021 EMS Ltd. All rights reserved. Page 2 of 2 TSD108-0001-99 (Issue 4) 25/08/2021 AJM
This is a life safety product. Only use manufacturer approved battery types.
Failure to do so may result in damage to the product.
DO NOT mix batteries of different type or age.
When replacing batteries; remove all old batteries before fitting replacements.

This manual suits for next models

3

Other SmartCell Marine Equipment manuals

SmartCell SC-33-0120-0001-99 User manual

SmartCell

SmartCell SC-33-0120-0001-99 User manual

SmartCell SC-33-0230-0001-99 User manual

SmartCell

SmartCell SC-33-0230-0001-99 User manual

SmartCell SC-41-0200-0001-99 User manual

SmartCell

SmartCell SC-41-0200-0001-99 User manual

SmartCell SC-31-0100-0001-99 User manual

SmartCell

SmartCell SC-31-0100-0001-99 User manual

SmartCell SC-32-0110-0001-99 User manual

SmartCell

SmartCell SC-32-0110-0001-99 User manual

Popular Marine Equipment manuals by other brands

IMAGENEX DT101Xi Technical manual

IMAGENEX

IMAGENEX DT101Xi Technical manual

Koden KDS-8000BB installation manual

Koden

Koden KDS-8000BB installation manual

GUIDANCE MARINE Artemis Mk6 Installer's guide

GUIDANCE MARINE

GUIDANCE MARINE Artemis Mk6 Installer's guide

Furuno SC-33 Operator's manual

Furuno

Furuno SC-33 Operator's manual

Raymarine Autohelm 3000 Service guide

Raymarine

Raymarine Autohelm 3000 Service guide

Raymarine Quantum 2 installation instructions

Raymarine

Raymarine Quantum 2 installation instructions

Raymarine ST60 Tridata Owner's handbook

Raymarine

Raymarine ST60 Tridata Owner's handbook

Seastar Solutions HP6016 installation instructions

Seastar Solutions

Seastar Solutions HP6016 installation instructions

Simrad IS42J quick guide

Simrad

Simrad IS42J quick guide

Seago Sea Master ISO 9650-1 Owner's operating manual

Seago

Seago Sea Master ISO 9650-1 Owner's operating manual

Dometic DCU installation manual

Dometic

Dometic DCU installation manual

System Sensor EBS Installation and maintenance instructions

System Sensor

System Sensor EBS Installation and maintenance instructions

Furuno FCV-1150 Specifications

Furuno

Furuno FCV-1150 Specifications

Honeywell HERMetic OXY Operation and service manual

Honeywell

Honeywell HERMetic OXY Operation and service manual

KVH Industries TracPhone F33 user guide

KVH Industries

KVH Industries TracPhone F33 user guide

Harken HYDRO POWER UNIT 1 Installation and operation manual

Harken

Harken HYDRO POWER UNIT 1 Installation and operation manual

Exalto 232BD user manual

Exalto

Exalto 232BD user manual

jotron Tron 60AIS user manual

jotron

jotron Tron 60AIS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.