manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Control Unit
  8. •
  9. Emerson fisher 6365 Series User manual

Emerson fisher 6365 Series User manual

This manual suits for next models

4

Other Emerson Control Unit manuals

Emerson Baumann 83000 User manual

Emerson

Emerson Baumann 83000 User manual

Emerson Yarway Manual

Emerson

Emerson Yarway Manual

Emerson Fisher Vee-Ball SS-84PSV4 User manual

Emerson

Emerson Fisher Vee-Ball SS-84PSV4 User manual

Emerson KTM Hindle Instruction Manual

Emerson

Emerson KTM Hindle Instruction Manual

Emerson FISHER NotchFlo DST User manual

Emerson

Emerson FISHER NotchFlo DST User manual

Emerson Neotecha Installation and operating instructions

Emerson

Emerson Neotecha Installation and operating instructions

Emerson 1805 Series User manual

Emerson

Emerson 1805 Series User manual

Emerson Fisher Type 289P User manual

Emerson

Emerson Fisher Type 289P User manual

Emerson Fisher A11 User manual

Emerson

Emerson Fisher A11 User manual

Emerson Keystone Figure 221 Series User manual

Emerson

Emerson Keystone Figure 221 Series User manual

Emerson J Series User manual

Emerson

Emerson J Series User manual

Emerson PACSystems RX3i IEC 61850 User manual

Emerson

Emerson PACSystems RX3i IEC 61850 User manual

Emerson HANCOCK Manual

Emerson

Emerson HANCOCK Manual

Emerson Varec 5010 Series Owner's manual

Emerson

Emerson Varec 5010 Series Owner's manual

Emerson CROSBY STYLE HC ISOFLEX Guide

Emerson

Emerson CROSBY STYLE HC ISOFLEX Guide

Emerson Keystone K-LOK H Series Manual

Emerson

Emerson Keystone K-LOK H Series Manual

Emerson Fisher 8532 User manual

Emerson

Emerson Fisher 8532 User manual

Emerson Fisher POSI-SEAL A81 User manual

Emerson

Emerson Fisher POSI-SEAL A81 User manual

Emerson 47D01U-843 User manual

Emerson

Emerson 47D01U-843 User manual

Emerson Unidrive M700 User manual

Emerson

Emerson Unidrive M700 User manual

Emerson Keystone K-Lok 360 Series Operating instructions

Emerson

Emerson Keystone K-Lok 360 Series Operating instructions

Emerson CROSBY Guide

Emerson

Emerson CROSBY Guide

Emerson Raimondi User manual

Emerson

Emerson Raimondi User manual

Emerson Sempell PSRV VS99 User manual

Emerson

Emerson Sempell PSRV VS99 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Office or view a copy at www.fisher.com. For further
information refer to: Type 6365 and 6358 Series
Instruction Manual, D102692X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
Type 6365, DN 6 / 1/4 in. SEP 1
Type 6358, 1/4 NPT
Specifications
Pilot Descriptions
Type 6365: Set pressure range from 35 mbar to
0.14 bar / 14 in. w.c. to 2 psig. This pilot has a high
gain restriction standard.
Type 6358: Set pressure range from 0.21 to 8.6 bar /
3 to 125 psig. This pilot has a restriction plug.
Type 6358B: Set pressure range from 0.14 to
8.6 bar / 2 to 125 psig. This pilot is available with a
high, medium or low gain restriction.
Type 6358EB: Set pressure range of 5.2 to
24.1 bar / 75 to 350 psig. This pilot is available
with a high or low gain restriction.
Type 6358EBH: Set pressure range of 17.2 to
41.4 bar / 250 to 600 psig. This pilot is available
with a high or low gain restriction.
Maximum Relief (Inlet) Pressure (Including Buildup)(1)
Depends upon maximum inlet pressure for
complete relief valve as specified in appropriate
main valve bulletin.
Pilot Set Pressure Ranges(1)(2)
See Table 1
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive
Temperature Capability(1)
-29 to 66°C / -20 to 150°F
Pressure Connection
1/4 NPT (internal)
Installation
!
WARNING
Only qualied personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents uid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
Personal injury, equipment damage or
leakage due to escaping uid or bursting
of pressure-containing parts may result
if this regulator is overpressured or
is installed where service conditions
could exceed the limits given in the
Specications section, or where
conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
uid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to the
external pipe threads. For anged bodies, use suitable
line gaskets and approved piping and bolting practices.
Install the regulator in any position desired, unless
otherwise specied, but be sure ow through the body
is in the direction indicated by the arrow on the body.
1. The pressure/temperature limits in this installation guide or any applicable standard limitation should not be exceeded.
2. Set pressure is dened as the pressure at which the pilot starts to discharge.
Type 6365 and 6358 Series
Installation Guide
D102692X014
English – April 2016
Overpressure Protection
The recommended pressure limitations are stamped
on the regulator nameplate. Some type of overpressure
protection is needed if the actual inlet pressure exceeds the
maximum operating outlet pressure rating. Overpressure
protection should also be provided if the regulator inlet
pressure is greater than the safe working pressure of the
downstream equipment.
Regular operation below the maximum pressure
limitations does not preclude the possibility of damage
from external sources or debris in the line. The
regulator should be inspected for damage after any
overpressure condition.
Startup
The regulator is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly
open the upstream and downstream shutoff valves.
Adjustment
To change the set pressure, remove the closing cap or
loosen the locknut and turn the adjusting screw clockwise
to increase set pressure or counterclockwise to decrease
pressure. Monitor the set pressure with a test gauge
during the adjustment. Replace the closing cap or tighten
the locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before
attempting disassembly.
Parts List
6358 Series Pilots
Key Description
1 Body
2 Spring Case
3 Body Plug
4 Valve Plug and Stem Assembly
5* Diaphragm Assembly
6 Connector Cap
7 Control Spring
8 Spring Seat
9 Stem Guide
10 Adjusting Screw
11 Locknut
12 Closing Cap
13* Body Plug O-ring
14 Valve Spring
15 O-ring, Type 6358EBH (not shown)
16* Vent Assembly
17 Machine Screw
18 O-ring, Type 6358EB (not shown)
19* Closing Cap Gasket, Types 6358 and 6358B
20 Restriction Plug, Type 6358
20 Restriction, Types 6358B, 6358EB and 6358EBH
21 Filter
29 Gauge
29 Pipe Plug
34 Pipe Nipple
36* Connector Cap Gasket
37* Stem O-ring
38 Lower Spring Seat, Types 6358EB and 6358EBH (not shown)
40 Diaphragm Limiter, Type 6358EB (not shown)
42 NACE Tag
43 Tag Wire
Table 1. Pilot Set Pressure Ranges and Control Spring Information
PILOT TYPE SPRING RANGE(1)
SPRING COLOR WIRE DIAMETER FREE LENGTH
bar psig mm In. mm In.
6365 35 mbar to 0.14 bar 14 in. w.c. to 2 psig Yellow 1.78 0.070 54.1 2.13
6358
0.21 to 1.24 3 to 18 Green 3.05 0.120 57.2 2.25
0.7 to 2.76 10 to 40 Yellow 3.76 0.148 50.8 2.00
1.4 to 8.62 20 to 125 Red 4.75 0.187 55.6 2.19
6358B
0.14 to 0.69 2 to 10 Black 2.59 0.102 53.8 2.12
0.21 to 1.24 3 to 18 Green 3.05 0.120 54.1 2.13
0.69 to 2.07 10 to 30 Silver 3.61 0.142 54.1 2.13
1.03 to 2.76 15 to 40 Yellow 3.76 0.148 50.8 2.00
2.07 to 4.14 30 to 60 Blue 4.62 0.182 49.3 1.94
0.7 to 8.62 10 to 125 Red 4.75 0.187 55.6 2.19
6358EB
5.17 to 9.65 75 to 140 Green 5.72 0.225 94.0 3.70
8.96 to 13.8 130 to 200 Blue 6.66 0.262 97.8 3.85
12.4 to 24.1 180 to 350 Red 7.47 0.294 107 4.22
6358EBH 17.2 to 31.0 250 to 450 Blue 6.66 0.262 97.8 3.85
27.6 to 41.4 400 to 600 Red 7.47 0.294 107 4.22
1. Main valve may limit advertised spring range. See individual main valve bulletin for additional information.
*Recommended spare part.
Type 6365 and 6358 Series
2
Type 6365 Pilot
Key Description
1 Body Assembly
2 Spring Case
3 Body Plug
4* Plug/Stem Assembly
5* Diaphragm Assembly
6 Connector Cap
7 Control Spring
8 Spring Seat
9 Plug/Stem Guide
10 Adjusting Screw
11 Locknut
12 Closing Cap
13* Body Plug Gasket
14* Plug/Stem Spring
16 Vent Assembly
17 Machine Screw
19* Closing Cap Gasket
20 Restriction
36* Connector Cap Gasket
Figure 2. Type 6365 Pilot Assembly
1
13
3
17
16
2
12
11 10
8
6
14
20
4
19
7
36
5
9
TYPE 6365 PILOT INTERIOR VIEW
C0542-2
*Recommended spare part.
Figure 1. Type 6358 and 6358B Pilots
12
10
19
8
6
5
14
9
37
3
13
1
4
20
16
36
7
2
11
TYPE 6358 PILOT INTERIOR VIEW
A6920
10
19
8
6
5
14
9
37
313
1
4
20
16
36
7
2
11
12
TYPE 6358B PILOT INTERIOR VIEW
B2619-2
Type 6365 and 6358 Series
3
Type 6365 and 6358 Series
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D102692X014 © 2004, 2018 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 09/18.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.