Smeg SHB450X User manual

Instructions Manual
SHB450X – SHB600X – SHB900X

2
2
INDEX
RECOMMENDATIONS AND SUGGESTIONS..................................................................................................................... 3
CHARACTERISTICS.............................................................................................................................................................4
INSTALLATION...................................................................................................................................................................... 5
USE........................................................................................................................................................................................8
MAINTENANCE.....................................................................................................................................................................9
EN

EN 3
3
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accordingly, you may find
descriptionsofindividualfeaturesthatdonotapplytoyourspecificappliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or improper
installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm (some
models can be installed at a lower height, please refer to the paragraphs on working dimensions
andinstallation).
• Checkthatthemains voltagecorrespondstothatindicatedontheratingplatefixedtotheinside of
thehood.
• ForClassIappliances,checkthatthedomesticpowersupplyguaranteesadequateearthing.
Connecttheextractortotheexhaust fluethrougha pipe of minimumdiameter120mm.The route
ofthefluemustbeasshortaspossible.
• Donotconnecttheextractorhoodtoexhaustductscarryingcombustionfumes(boilers,fireplaces,
etc.).
• Iftheextractorisusedinconjunctionwithnon-electricalappliances(e.g.gasburningappliances),a
sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of
exhaust gas.Thekitchenmust havean opening communicatingdirectly withthe openairinorder
to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances
supplied with energy other than electric, the negative pressure in the room must not exceed 0,04
mbartopreventfumesbeingdrawnbackintotheroombythecookerhood.
• In the event of damage to the power cable, it must be replaced by the manufacturer or by the
technicalservicedepartment,inordertopreventanyrisks.
“WARNING:Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay
resultinelectricalhazards.”
USE
• Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells.
• Neverusethehoodforpurposesotherthanforwhichithasbeendesigned.
• Neverleavehighnakedflamesunderthehoodwhenitisinoperation.
• Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not
engulfthesides.
• Deepfatfryersmustbecontinuouslymonitoredduringuse:overheatedoilcanburstintoflames.
• Donotflambèundertherangehood;riskoffire
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
soryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen givensu-
pervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
• “WARNING:Accessiblepartsmaybecomehotwhenusedwithcookingappliances.”.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance
work.
• Cleanand/orreplacetheFiltersafterthespecifiedtimeperiod(Firehazard).
• Cleanthehoodusingadampclothandaneutralliquiddetergent.
Thesymbol on theproduct or on its packaging indicates that this product may not be treatedas household waste. Instead it
shallbehandedovertotheapplicablecollectionpointfortherecyclingofelectricalandelectronicequipment.Byensuringthisproduct
is disposed of correctly, you willhelpprevent potentialnegative consequencesfor the environment and humanhealth, which could
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product,
pleasecontactyourlocalcityoffice,yourhouseholdwastedisposalserviceortheshopwhereyoupurchasedtheproduct.
2°

EN 4
4
CHARACTERISTICS
Dimensions
890
420
448 - 598 - 898
Min.
550mm
Min.
550mm
Components
Ref. Q.ty Product components
1 1 Hood Body complete with: Controls, Light, Suction Unit,
Filters, Lower Duct
71 PVC Pipe (fitted)
81 Inclinable grid (fitted)
91 Reduction flange ø 150-120 mm
10 1 Metal cover
10a 1 Dumper
Ref. Q.ty Assembly components
11a 2 SB 12/10 Plugs
Q.ty Documents
1 Instruction Manual
10a
11a
8
7
10
9

EN 5
5
Type Hood 45 60 90
X 180 240 390
550 mm min
11a
X
808
540 300
250
X
INSTALLATION
Boring the wall
If you want to use the hood in suction version with the air outlet at the back of the hood, make
sure to follow the indications given below in the drawing for a correct boring operation of the air
outlet opening.
When installing the hood in recycling version it has to be taken into consideration that space re-
maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm.
On the wall, trace:
• a vertical line up to the ceiling or top limit, at the centre of the area where you intend to fit
the hood;
• a horizontal line at: 550 mm min. above the cooking hob;
• As shown, mark a reference point at 808 mm above the horizontal reference line, and at X
mm (X= see table in figure) to the right of the vertical reference line.
• Repeat this operation on the opposite side, checking levelling.
• Drill the points marked using a ø 12 mm bit
• Insert plugs with screws and brackets 11a in the holes then tighten them.
Rear air outlet
zone

EN 6
6
Hood body assembly
• Adjust the two screws Vr of brackets 11a, by just placing them
in position.
• Hook the hood body to the two brackets 11a.
• Pull the Comfort Panel to open it, remove the filters one by
one, push them towards the rear part of the unit and pull
downwards at the same time .
• From inside the hood body, tighten the screws Vr to level the
body.
Vr
11a
Connection
AIR OUTLET IN A DUCTING HOOD VERSION
When installing the hood in ducting version, basing on the in-
staller’s choice, a rigid or a flexible pipe with a ø 150 or 120 mm
is used in order to connect the hood to the air outlet piping. The
pipe connection can be made on the upper part or on the rear side
of the hood.
Before connecting the hood to the air outlet ducting remove the
lateral air outlet grid 8and the plastic tube 7. The adapting flange
9has to be removed only in case the connecting diameter is 150.
To install the dumper 10a on the hood body outlet.
REAR AIR OUTLET
• When drilling the air outlet hole in the wall proceed in accor-
dance with the scheme in the part concerning the wall drilling.
• Use a pair of tongs when breaking the rear air outlet hole in the
wall.
• In case the connection is made by using a ø 120 mm pipe insert
the reduction flange 9on the Dumper 10a.
• Fix the pipe with an adequate quantity of pipe clamps. This
material is not supplied together with the hood.
• Remove the charcoal filter if present.
• Fix the metal cover 10 to the upper air outlet hole of the hood
by using the screws supplied.
UPPER AIR OUTLET
• In case the connection is made by using a ø 120 mm pipe insert
the reduction flange 9on the Dumper 10a.
• Use a pair of tongs when removing the central part of the metal
cover 10. Fix the cover to the air outlet hole of the hood by us-
ing the screws supplied.
• Fix the pipe with an adequate quantity of pipe clamps. This
material is not supplied together with the hood.
• Remove the charcoal filter if present.
10
10
10a
10a
9
ø 150
ø 120

EN 7
7
AIR OUTLET IN A RECYCLING HOOD VERSION
• In case the components requested for the recycling functioning
have been removed earlier these have to be positioned again.
• Put the plastic tube onto the flange 7.
• Place the air outlet grid 8on the air outlet. Make sure that the
position of the grid is correct.
• Make sure that charcoal filters have been placed inside the
hood.
8
7
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.

EN 8
8
USE
Control panel
Button Function Led
A Turns the lighting system on and off at maximum
intensity. On/Off
Turns the lighting system on and off in Courtesy Light
mode. On/Off
B Turns the Motor off.
Press and hold for approximately 5 seconds to Lock /
Unlock the Keyboard, for example in order to clean the
surface.
The buttons turn light up one at a time in cycle.
C Turns the Motor on at Speed one. On/Off
D Turns the Motor on at Speed two. On/Off
E Turns the Motor on at Speed three. On/Off
F Activates/Deactivates intensive speed from any other
speed, including motor off. This speed is set to operate
for 10 minutes, after which the system returns to the
speed that was set before. Suitable to deal with
maximum levels of cooking fumes. Can also be
deactivated by pressing button B.
Flashes once a second.
Press and hold the button for approximately 5 seconds,
with all the loads turned off (Motor and Lights), to turn
the Activated Charcoal Filter alarm on/off.
Button B (Flashes twice)-Alarm Activated.
Button B (Flashes once)-Alarm Deactivated.
G 24H function
Turns the motor On/Off at speed one and allows
recirculation for 10 minutes every hour. It cannot be
activated if the Intensive or Delay functions are in use.
On/Off
When the filters alarm is triggered, the alarm can be
reset by pressing and holding this button for
approximately 5 seconds.
These indications are only visible when the motor is
turned off.
Bflashes three times.
When the procedure terminates, the indication shown
previously turns off:
Button G flashes, indicating the need to wash the metal
grease filters. The alarm is triggered after the Hood has
been in operation for 100 working hours.
Button G flashes, indicating the need to change the
activated charcoal filters, and also to wash the metal grease
filters. The alarm is triggered after the Hood has been in
operation for 200 working hours.
H Delay function
Activates/Deactivates automatic switch-off with a 30’
delay. Suitable to complete elimination of residual
odours. Can be activated from any position. It cannot
be activated if the Intensive or 24H functions are in
use.
On/Off
Press and hold the button for approximately 5 seconds,
with all the loads turned off (Motor and Lights), to turn
the Remote control on/off.
Button B (Flashes twice)-Remote control Activated.
Button B (Flashes once)-Remote control Deactivated.
R Remote control receiver.

EN 9
9
MAINTENANCE
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered
by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-
AAA type (not included).
• Do not place the remote control near to heat sources.
• Used batteries must be disposed of in the proper manner.
Cleaning the Comfort Panels
• Pull the Comfort Panel to open it.
• Disconnect the panel from the hood canopy by sliding the fix-
ing pin lever.
• The comfort panel must never be washed in a dishwasher.
• Clean the outside by using a damp cloth and neutral liquid de-
tergent.
• Clean the inside as well by using a damp cloth and neutral de-
tergent; do not use wet cloths or sponges, or jets of water; do
not use abrasive substances.
• When the above operation has been completed, hook the panel
back to the hood canopy and close it by turning the knob in the
opposite direction.

EN 1
10
Metal grease filters
They can be washed in the dishwasher, and need to be cleaned
whenever Button Gflashes or at least once every 2 months use,
or more frequently if use is particularly intensive.
Resetting the alarm signal
• Turn the Lights and the Suction motor off, then disable the 24h
function, if enabled.
• Press button Gand hold for approximately 5 seconds (See
paragraph on Use).
Cleaning the filters
• Pull the comfort panels to open them.
• Remove the filters one by one pushing them towards the back
side of the hood unit and simultaneously pulling downwards.
• Any kind of bending of the filters has to be avoided when
washing them. Before fitting them again into the hood make
sure that they are completely dry. (The colour of the filter sur-
face may change throughout the time but this has no influence
to the filter efficiency).
• When fitting the filters into the hood pay attention that they are
mounted in correct position the handle facing outwards.
• Close the comfort panel.
.

EN 1
11
Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when Gstarts to flash, or at least
once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction
motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press F and hold for approximately 5 seconds:
• Button B flashes twice -- A.C. Filter saturation alarm ACTIVATED
• Button B flashes once -- A.C. Filter saturation alarm DEACTIVATED
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press button Gand hold for approximately 5 seconds (See
paragraph on Use).
Changing the Filter
• Open the comfort panels pulling them downwards.
• Remove grease filters.
• Remove the saturated activated charcoal filters, as indicated
(A).
• Fit the new filters, as indicated (B).
• Replace the metal grease filters.
• Close the comfort panels.
A
B
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Refit the Support, fixing it in place with the two screws re-
moved as above.

436006041_ver2
This manual suits for next models
2
Table of contents
Other Smeg Ventilation Hood manuals

Smeg
Smeg SHW410X User manual

Smeg
Smeg KSEV90X Technical manual

Smeg
Smeg KSEIV950X Technical manual

Smeg
Smeg Kitchen Hood KSE9600XL Setup guide

Smeg
Smeg KSEC61X User manual

Smeg
Smeg KSEG120X User manual

Smeg
Smeg SA520TX90 User manual

Smeg
Smeg K24X60 User manual

Smeg
Smeg SA480T/90 Quick start guide

Smeg
Smeg K24X90 User manual
Popular Ventilation Hood manuals by other brands

EAS Electric
EAS Electric EMRH604X instruction manual

Rinnai
Rinnai RH - 60 ER instruction manual

Miele
Miele DAR 1125 Operating and installation instructions

Lamona
Lamona LAM2104 Instructions and installation

KOBE
KOBE RAX2830SQB-2 Installation instructions and operation manual

Gaggenau
Gaggenau AH 600-190 Operating and assembly instructions